161 resultados para DISTAL INTERPHALANGEAL JOINT
Resumo:
Background/Purpose: Since the end of 2009, an ultrasound scoring call SONAR has been implemented for RA patients as a routine tool in the SCQM registry (Swiss Clinical Quality Management registry for rheumatic diseases). A cross-sectional evaluation of patients with active disease and clinical remission according to the DAS28ESR and the novel ACR/EULAR remission criteria from 2010 clearly indicated a good correlational external validity of synovial pathologies with clinical disease activity in RA (2012 EULAR meeting. Objective: of this study was to evaluate the sensitivity to change of B-mode and Power-Doppler scores in a longitudinal perspective along with the changes in DAS28ESR in two consecutive visits among the patients included in the SCQM registry Methods: All patients who had at least two SONAR scores and simultaneous DAS28ESR evaluations between December 2009 and June 2012 were included in this study. The data came from 20 different operators working mostly in hospitals but also in private practices, who had received a previous teaching over 3 days in a reference center. The SONAR score includes a semi-quantitative B mode and Power-Doppler evaluation of 22 joints from 0 to 3, maximum 66 points for each score. The selection of these 22 joints was done in analogy to a 28 joint count and further restricted to joint regions with published standard ultrasound images. Both elbows and wrist joints were dynamically scanned from the dorsal and the knee joints from a longitudinal suprapatellar view in flexion and in joint extension. The bilateral evaluation of the second to fifth metacarpophalangeal and proximal interphalangeal joints was done from a palmar view in full extension, and the Power-Doppler scoring from a dorsal view with hand and finger position in best relaxation. Results: From the 657 RA patients with at least one score performed, 128 RA patients with 2 or more consultations of DAS28ESR, and a complete SONAR data set could be included. The mean (SD) time between the two evaluations was 9.6 months (54). The mean (SD) DAS28ESR was: 3.5 (1.3) at the first visit and was significantly lower (mean 3.0, SD.2.0, p:_0.0001) at the second visit. The mean (SD) of the total B mode was 12 (9.5) at baseline and 9.6 (7.6) at follow-up (p_0.0004). The Power-Doppler score at entry was 2.9 (5.7) and 1.9 (3.6), at the second visit, p _0.0001. The Pearson r correlation between change in DAS28ESR and the B mode was 0.44 (95% CI: 0.29, 0.57, p_ 0.0001),and 0.35 (95% CI: 0.16, 0.50, p _ 0.0002) for the Power-Doppler score,. Clinical relevant change in DAS (_1.1) was associated with a change of total B mode score _3 in 23/32 patients and a change a Doppler score _0.5 in 19/26. Conclusion: This study confirms that the SONAR score is sensitive to change and provides a complementary method of assessing RA disease activity to the DAS that could be very useful in daily practice.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
Deficiency of carbohydrate sulfotransferase 3 (CHST3; also known as chondroitin-6-sulfotransferase) has been reported in a single kindred so far and in association with a phenotype of severe chondrodysplasia with progressive spinal involvement. We report eight CHST3 mutations in six unrelated individuals who presented at birth with congenital joint dislocations. These patients had been given a diagnosis of either Larsen syndrome (three individuals) or humero-spinal dysostosis (three individuals), and their clinical features included congenital dislocation of the knees, elbow joint dysplasia with subluxation and limited extension, hip dysplasia or dislocation, clubfoot, short stature, and kyphoscoliosis developing in late childhood. Analysis of chondroitin sulfate proteoglycans in dermal fibroblasts showed markedly decreased 6-O-sulfation but enhanced 4-O-sulfation, confirming functional impairment of CHST3 and distinguishing them from diastrophic dysplasia sulphate transporter (DTDST)-deficient cells. These observations provide a molecular basis for recessive Larsen syndrome and indicate that recessive Larsen syndrome, humero-spinal dysostosis, and spondyloepiphyseal dysplasia Omani type form a phenotypic spectrum.
Resumo:
The best indirect evidence that increased bone turnover contributes to fracture risk is the fact that most of the proven therapies for osteoporosis are inhibitors of bone turnover. The evidence base that we can use biochemical markers of bone turnover in the assessment of fracture risk is somewhat less convincing. This relates to natural variability in the markers, problems with the assays, disparity in the statistical analyses of relevant studies and the independence of their contribution to fracture risk. More research is clearly required to address these deficiencies before biochemical markers might contribute a useful independent risk factor for inclusion in FRAX(®).
Resumo:
Risk factors for fracture can be purely skeletal, e.g., bone mass, microarchitecture or geometry, or a combination of bone and falls risk related factors such as age and functional status. The remit of this Task Force was to review the evidence and consider if falls should be incorporated into the FRAX® model or, alternatively, to provide guidance to assist clinicians in clinical decision-making for patients with a falls history. It is clear that falls are a risk factor for fracture. Fracture probability may be underestimated by FRAX® in individuals with a history of frequent falls. The substantial evidence that various interventions are effective in reducing falls risk was reviewed. Targeting falls risk reduction strategies towards frail older people at high risk for indoor falls is appropriate. This Task Force believes that further fracture reduction requires measures to reduce falls risk in addition to bone directed therapy. Clinicians should recognize that patients with frequent falls are at higher fracture risk than currently estimated by FRAX® and include this in decision-making. However, quantitative adjustment of the FRAX® estimated risk based on falls history is not currently possible. In the long term, incorporation of falls as a risk factor in the FRAX® model would be ideal.
Resumo:
The microbiological diagnosis of periprosthetic joint infection (PJI) is crucial for successful antimicrobial treatment. Cultures have limited sensitivity, especially in patients receiving antibiotics. We evaluated the value of multiplex PCR for detection of microbial DNA in sonication fluid from removed orthopedic prostheses. Cases of PJI in which the prosthesis (or part of it) was removed were prospectively included. The removed implant was sonicated, and the resulting sonication fluid was cultured and subjected to multiplex PCR. Of 37 PJI cases (17 hip prostheses, 14 knee prostheses, 4 shoulder prostheses, 1 elbow prosthesis, and 1 ankle prosthesis), pathogens were identified in periprosthetic tissue in 24 (65%) cases, in sonication fluid in 23 (62%) cases, and by multiplex PCR in 29 (78%) cases. The pathogen was detected in 5 cases in sonication fluid only (Propionibacterium acnes in all cases; none of these patients had previously received antibiotics) and in 11 cases by multiplex PCR only (all of these patients had previously received antibiotics). After exclusion of 8 cases caused by P. acnes or Corynebacterium species, which cannot be detected due to the absence of specific primers in the PCR kit, sonication cultures were positive in 17 cases and multiplex PCR sonication cultures were positive in 29 cases (59% versus 100%, respectively; P < 0.01). Among 19 cases (51%) receiving antibiotics, multiplex PCR was positive in all 19 (100%), whereas sonication cultures grew the organism in 8 (42%) (P < 0.01). Multiplex PCR of sonication fluid is a promising test for diagnosis of PJI, particularly in patients who previously received antibiotics. With modified primer sets, multiplex PCR has the potential for further improvement of the diagnosis of PJI.
Resumo:
A newborn female with partial trisomy for the distal part of the long arm of the chromosome 14 (14q24 --> qter) resulting from a paternal balanced translocation (3;14) is described. We compare her phenotype with eight other individuals with trisomy 14q24 --> qter.
Resumo:
Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.
Resumo:
Cet article se veut être un condensé des bases nécessaires à la pratique d'une ponction et, ou infiltration articulaire, des indications principales aux complications potentielles en passant par la description de la procédure et de ses contre-indications. La ponction du genou fait l'objet d'une description plus détaillée. Les données permettant de justifier une façon particulière de procéder ont spécifiquement été recherchées dans la littérature (Cochrane et Medline, termes de recherche : arthrocentesis ; joint aspiration). Le détail de ces données, comme par exemple le résultat d'études, ne trouve pas sa place dans ce résumé mais fait l'objet d'une publication à part. What should be known in order to practice safely a joint aspiration and/or infiltration is summarized in the following article. This summary includes various aspects, such as the indications and contraindications, the procedure itself, and the possible complications. The arthrocentesis of the knee is described in more details. Data in support of a specific modus operandi have been searched for in Cochrane and Pubmed (key words: arthrocentesis, joint aspiration). Only the conclusions of this research are exposed in this summary. A more comprehensive article will be published
Resumo:
Epiphyseal fractures of the distal humerus and their treatment are common, source of many complications that may be immediate but also delayed. If the families accept the possibility of trauma to their child as part of his leisure activities or sports at times intense, they are much more intolerant if their child does not return after injury and repair, optimal function and physical performance unchanged. This intolerance, faced with the trauma but not its consequences, requires us to be particularly careful in the information given to the patient but also in monitoring the first few weeks. The treatment of epiphyseal fractures remains difficult and must be performed by trained teams, aware of the subtleties of pathology. It is essential to organize close monitoring and critical to be able to correct errors or secondary displacement in the first 15 days.
Resumo:
The ideal reconstruction technique for complex defects of the lower limb consists of replacing tissue with similar tissue in an attempt to achieve a good functional result. A 23-year-old white male sustained a crush injury with a grade IIIB open ankle dislocation. After open reduction and fixation, the patient developed severe osteomyelitis at the tibiotalar joint requiring a staged and radical debridement with a substantial combined soft tissue and bony defect over the distal tibia, fibula, and talus area. The reconstructive approach consisted of a modified model of the propeller flap, implementing the spare part concept in a 2-stage procedure using a prefabricated and vascularized "double-barrel" fibular graft. At 17 months postoperatively, a plain radiograph showed bony union with complete and stable coverage of the soft tissue defect. The patient was fully weightbearing. In conclusion, there is evidence to suggest that the established concept of a soft tissue propeller flap can be implemented on bone.
Resumo:
A cross-over controlled administration study of smoked cannabis was carried out on occasional and heavy smokers. The participants smoked a joint (11 % Δ9-tetrahydrocannabinol (THC)) or a matching placebo on two different occasions. Whole blood (WB) and oral fluid (OF) samples were collected before and up to 3.5 h after smoking the joints. Pharmacokinetic analyses were obtained from these data. Questionnaires assessing the subjective effects were administered to the subjects during each session before and after the smoking time period. THC, 11-hydroxy-THC (11-OH-THC) and 11-nor-9-carboxy-THC (THCCOOH) were analyzed in the blood by gas chromatography or liquid chromatography (LC)-tandem mass spectrometry (MS/MS). The determination of THC, THCCOOH, cannabinol (CBN), and Δ9-tetrahydrocannabinolic acid A (THC-A) was carried out on OF only using LC-MS/MS. In line with the widely accepted assumption that cannabis smoking results in a strong contamination of the oral cavity, we found that THC, and also THC-A, shows a sharp, high concentration peak just after smoking, with a rapid decrease in these levels within 3 h. No obvious differences were found between both groups concerning THC median maximum concentrations measured either in blood or in OF; these levels were equal to 1,338 and 1,041 μg/L in OF and to 82 and 94 μg/L in WB for occasional and heavy smokers, respectively. The initial WB THCCOOH concentration was much higher in regular smokers than in occasional users. Compared with the occasional smokers, the sensation of confusion felt by the regular smokers was much less while the feeling of intoxication remained almost unchanged.