131 resultados para gamma detection
Resumo:
During fetal life, CD4(+)CD3(-) lymphoid tissue inducer (LTi) cells are required for lymph node and Peyer's patch development in mice. In adult animals, CD4(+)CD3(-) cells are found in low numbers in lymphoid organs. Whether adult CD4(+)CD3(-) cells are LTi cells and are generated and maintained through cytokine signals has not been directly addressed. In this study we show that adult CD4(+)CD3(-) cells adoptively transferred into neonatal CXCR5(-/-) mice induced the formation of intestinal lymphoid tissues, demonstrating for the first time their bona fide LTi function. Increasing IL-7 availability in wild-type mice either by IL-7 transgene expression or treatment with IL-7/anti-IL-7 complexes increased adult LTi cell numbers through de novo generation from bone marrow cells and increased the survival and proliferation of LTi cells. Our observations demonstrate that adult CD4(+)lineage(-) cells are LTi cells and that the availability of IL-7 determines the size of the adult LTi cell pool.
Resumo:
The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.
Resumo:
Purpose: To identify patterns of initially pain freedom response in patients with classical trigeminal neuralgia (CTN) with Gamma Knife surgery (GKS) and to compare their associated hypoesthesia and recurrence rates. Methods: In this study we analysed only 497 patients treated between July 1992 and November 2010, with a follow-up longer than 1 year, after excluding megadolichobasilar artery and multiple sclerosis related trigeminal neuralgia, as well as the second GKS treatments so as to have only cases with CTN and single radiosurgical treatment. GKS using a Gamma Knife (model B or C or Perfexion) was performed, based on both MRI and computer tomography (CT) targeting. A single 4-mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.8 mm (range 4.5-14) anteriorly to the emergence of the nerve. A median maximum dose of 85 Gy (range 70-90) was delivered. After empiric methods but also by using a chart with clear cut-off periods of pain free distribution, we were able to divide the initially pain free patients into 3 separate groups: within the first 48 hours, after 48 hours till 30 days and after 30 days, respectively. Results: The median follow- up period was 43.75 months (range 12-174.41). Four hundred and fifty-four patients (91.75%) were initially pain free in a median time of 10 days (range 1-459): 169 (37.2%) became pain free within the first 48 hours (pf<=48 h), compared to 194 (42.8%) between the 3-rd day and the day 30 (pf (>48 h, <=30 d)), inclusively and 91 (20%) patients after 30 days (pf>30d). Differences in terms of postoperative hypoesthesia were found with a p value of 0.014 as follows: the group pf<=48 h had 18 (13.7%) compared to pf (>48 h, <=30 d) with 30 (19%) and pf>30d with 22 (30.5%) patients developing a postoperative GKS hypoesthesia. One hundred and fifty seven (34.4%) patients initially pain free experienced a recurrence with a median delay of 24 months (range 0.62-150.06). There were no statistically significant differences between the three groups concerning recurrence (p value of 0.515). Conclusions: An important number of patients (169 cases, 37.2%) became pain free in the first 48 hours. Hypoesthesia rate was higher within the group becoming pain free after 30 days with a statistically significant difference between the three populations (p= 0.014). Further analysis will eventually help to elucidate the differences observed among groups.
Resumo:
The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.
Resumo:
A luminescent bacterial biosensor was used to quantify bioavailable arsenic in artificial groundwater. Its light production above the background emission was proportional to the arsenite concentration in the toxicologically relevant range of 0 to 0.5 mu M. Effects of the inorganic solutes phosphate, Fe(II) and silicate on the biosensor signal were studied. Phosphate at a concentration of 0.25 g L-1 phosphate slightly stimulated the light emission, but much less than toxicologically relevant concentrations of the much stronger inducer arsenite. No effect of phosphate was oberved in the presence of arsenite. Freshly prepared sodium silicate solution at a concentration of 10 g L-1 Si reduced the arsenite-induced light production by roughly 37%, which can be explained by transient polymerization leading to sequestration of some arsenic. After three days of incubation, silicate did not have this effect anymore, probably because depolymerization occurred. In the presence of 0.4 g L-1 Fe(II), the arsenite-induced light emission was reduced by up to 90%, probably due to iron oxidation followed by arsenite adsorption on the less soluble Fe(III) possibly along with some oxidation to the stronger adsorbing As(V). Addition of 100 mu M EDTA was capable of releasing all arsenic from the precipitate and to transform it into the biologically measurable, dissolved state. The biosensor also proved valuable for monitoring the effectiveness of an arsenic removal procedure based on water filtration through a mixture of sand and iron granules.
Resumo:
We have reported earlier that purified preparations of sheep fetal hemoglobin, but not adult hemoglobin, in concert with non-stimulatory doses of lipopolysaccharide (LPS) (lipid A), act cooperatively to regulate in vitro production of a number of cytokines, including TNFalpha, TGFbeta and IL-6 from murine and human leukocytes. Following in vivo treatment of mice with the same combination of hemoglobin and LPS, harvested spleen or peritoneal cells showed a similar augmented capacity to release these cytokines into culture supernatants. We report below that genetically cloned gamma-chain of human or sheep fetal hemoglobin, but not cloned alpha- or beta-chains, can produce this cooperative effect, as indeed can HPLC purified, heme-free, gamma-chains derived from cord blood fetal hemoglobin, and that purified haptoglobin completely abolishes the cooperative interaction.
Resumo:
Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.
Resumo:
A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.
Resumo:
Epidemiological studies show a prevalence of sexual abuse experience among girls from 14-33%. Although indicators of abuse are unspecific, the combination of several findings may be indicative: Somatic signs may be sexually transmitted diseases, vulvovaginal complaints. Psychosocial nonsexual indicators are abrupt behavioural changes, running away from home, eating disorders. Psychosexual signs are hypersexualisation of the language and behaviour, disturbed body image and gender identity. Indirect evidence of abuse is given not only in cases of old vaginal and anal lesions but also in situations, where deep tears of the hymen in the typical localization at the posterior part can be found. The workup and care for children in whom there is suspicion of abuse but no clear evidence asks for highly competent professionals in a multidisciplinary cooperation including pediatric gynecologists, child psychiatrists, children-protection groups and other specialists to avoid on one hand unjustified destabilisation or even destruction of familial structures but to assure on the other hand, that the child victims are treated and followed after in a short and long term comprehensive medical and psychosocial care.
Resumo:
Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.
Resumo:
This study aims to assess prevalence and pregnancy outcome for sex chromosome trisomies (SCTs) diagnosed prenatally or in the first year of life. Data held by the European Surveillance of Congenital Anomalies (EUROCAT) database on SCT cases delivered 2000-2005 from 19 population-based registries in 11 European countries covering 2.5 million births were analysed. Cases included were livebirths diagnosed to 1 year of age, fetal deaths from 20 weeks gestation and terminations of pregnancy for fetal anomaly (TOPFA). In all, 465 cases of SCT were diagnosed between 2000 and 2005, a prevalence of 1.88 per 10,000 births (95% CI 1.71-2.06). Prevalence of XXX, XXY and XYY were 0.54 (95% CI 0.46-0.64), 1.04 (95% CI 0.92-1.17) and 0.30 (95% CI 0.24-0.38), respectively. In all, 415 (89%) were prenatally diagnosed and 151 (36%) of these resulted in TOPFA. There was wide country variation in prevalence (0.19-5.36 per 1000), proportion prenatally diagnosed (50-100%) and proportion of prenatally diagnosed resulting in TOPFA (13-67%). Prevalence of prenatally diagnosed cases was higher in countries with high prenatal detection rates of Down syndrome. The EUROCAT prevalence rate for SCTs diagnosed prenatally or up to 1 year of age represents 12% of the prevalence expected from cytogenetic studies of newborn babies, as the majority of cases are never diagnosed or are diagnosed later in life. There is a wide variation between European countries in prevalence, prenatal detection and TOPFA proportions, related to differences in screening policies as well as organizational and cultural factors.
Resumo:
Frequent expression of cancer testis antigens (CTA) has been consistently observed in head and neck squamous cell carcinomas (HNSCC). For instance, in 52 HNSCC patients, MAGE-A3 and -A4 CTA were expressed in over 75% of tumors, regardless of the sites of primary tumors such as oral cavity or hypopharynx. Yet, T-cell responses against these CTA in tumor-bearing patients have not been investigated in detail. In this study, we assessed the naturally acquired T-cell response against MAGE-A3 and -A4 in nonvaccinated HNSCC patients. Autologous antigen-presenting cells pulsed with overlapping peptide pools were used to detect and isolate MAGE-A3 and MAGE-A4 specific CD4(+) T cells from healthy donors and seven head and neck cancer patients. CD4(+) T-cell clones were characterized by cytokine secretion. We could detect and isolate MAGE-A3 and MAGE-A4 specific CD4(+) T cells from 7/7 cancer patients analyzed. Moreover, we identified six previously described and three new epitopes for MAGE-A3. Among them, the MAGE-A3(111-125) and MAGE-A3(161-175) epitopes were shown to be naturally processed and presented by DC in association with HLA-DP and DR, respectively. All of the detected MAGE-A4 responses were specific for new helper epitopes. These data suggest that naturally acquired CD4(+) T-cell responses against CT antigens often occur in vivo in HNSCC cancer patients and provide a rationale for the development of active immunotherapeutic approaches in this type of tumor.
Resumo:
The in situ deposition of zinc oxide on gold nanoparticles in aqueous solution has been here successfully applied in the field of fingermark detection on various non-porous surfaces. In this article, we present the improvement of the multimetal deposition, an existing technique limited up to now to non-luminescent results, by obtaining luminescent fingermarks with very good contrast and details. This is seen as a major improvement in the field in terms of selectivity and sensitivity of detection, especially on black surfaces.
Resumo:
PURPOSE: To evaluate the diagnostic value of previously described MR features used for detecting suspected placental invasion according to observers' experience. MATERIALS AND METHODS: Our population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI (1.5T, T1- and T2-weighted MR-sequences without i.v. contrast), among them 12 with histopathologically proven placental invasion and 13 women (52%) without placental invasion used as control group. Two senior and two junior radiologists blindly and independently reviewed MR-examinations in view of 6 previously defined MR-features indicating presence and degree of placental invasion (placenta increta, accreta or percreta). For each reader the sensibility, specificity, and receiver operating curve (ROC) were calculated. Interobserver agreements between senior and junior readers were determined. Stepwise logistic regression was performed including the 6 MR-features predictive of placental invasion. RESULTS: Demographics between both groups were statistically equivalent. Overall sensitivity and specificity for placental invasion was 90.9% and 75.0% for seniors and 81.8% and 61.8% for juniors, respectively. The best single MR-feature indicating placental invasion was T2-hypointense placental bands (r(2)=0.28), followed by focally interrupted myometrial border, infiltration of pelvic organs and tenting of the bladder (r(2)=0.36). Interobserver agreement for detecting placental invasion was 0.64 for seniors and 0.41 for juniors, thus substantial and moderate, respectively. Seniors detected placental invasion and depth of infiltration with significantly higher diagnostic certitude than juniors (p=0.0002 and p=0.0282, respectively). CONCLUSION: MRI can be a reliable and reproducible tool for the detection of suspected placental invasion, but the diagnostic value significantly depends on observers' experience.
Resumo:
The EuroVacc 02 phase I trial has evaluated the safety and immunogenicity of a prime-boost regimen comprising recombinant DNA and the poxvirus vector NYVAC, both expressing a common immunogen consisting of Env, Gag, Pol, and Nef polypeptide domain from human immunodeficiency virus (HIV)-1 clade C isolate, CN54. 40 volunteers were randomized to receive DNA C or nothing on day 0 and at week 4, followed by NYVAC C at weeks 20 and 24. The primary immunogenicity endpoints were measured at weeks 26 and 28 by the quantification of T cell responses using the interferon gamma enzyme-linked immunospot assay. Our results indicate that the DNA C plus NYVAC C vaccine regimen was highly immunogenic, as indicated by the detection of T cell responses in 90% of vaccinees and was superior to responses induced by NYVAC C alone (33% of responders). The vaccine-induced T cell responses were (a) vigorous in the case of the env response (mean 480 spot-forming units/10(6) mononuclear cells at weeks 26/28), (b) polyfunctional for both CD4 and CD8 T cell responses, (c) broad (the average number of epitopes was 4.2 per responder), and (d) durable (T cell responses were present in 70% of vaccinees at week 72). The vaccine-induced T cell responses were strongest and most frequently directed against Env (91% of vaccines), but smaller responses against Gag-Pol-Nef were also observed in 48% of vaccinees. These results support the development of the poxvirus platform in the HIV vaccine field and the further clinical development of the DNA C plus NYVAC C vaccine regimen