281 resultados para cluster validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of a French translation of the Addiction Severity Index (ASI) in 100 (78 male) alcoholic patients. METHOD: Validity of the instrument was assessed by measuring test-retest and interrater reliability, internal consistency and convergence and discrimination between items and scales. Concurrent validity was assessed by comparing the scores from the ASI with those obtained from three other clinimetric instruments. RESULTS: Test-retest reliability of ASI scores (after a 10-day interval) was good (r = 0.63 to r = 0.95). Interrater reliability was evaluated using six video recordings of patient interviews. Severity ratings assigned by six rates were significantly different (p < .05), but 72% of the ratings assigned by those who viewed the videos were within two points of the interviewer's severity ratings. Cronbach alpha coefficient of internal consistency varied from 0.58 to 0.81 across scales. The average item-to-scale convergent validity (r value) was 0.49 (range 0.0 to 0.84) for composite scores and 0.35 (range 0.00 to 0.68) for severity ratings, whereas discriminant validity was 0.11 on average (range-0.19 to 0.46) for composite scores and 0.12 (range-0.20 to 0.52) for severity ratings. Finally, concurrent validity with the following instruments was assessed: Severity of Alcoholism Dependence Questionnaire (40% shared variance with ASI alcohol scale), Michigan Alcoholism Screening Test (2% shared variance with ASI alcohol scale) and Hamilton Depression Rating Scale (31% shared variance with ASI psychiatric scale). CONCLUSIONS: The Addiction Severity Index covers a large scope of problems encountered among alcoholics and quantifies need for treatment. This French version presents acceptable criteria of reliability and validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor Endothelial Marker-1 (TEM1/CD248) is a tumor vascular marker with high therapeutic and diagnostic potentials. Immuno-imaging with TEM1-specific antibodies can help to detect cancerous lesions, monitor tumor responses, and select patients that are most likely to benefit from TEM1-targeted therapies. In particular, near infrared(NIR) optical imaging with biomarker-specific antibodies can provide real-time, tomographic information without exposing the subjects to radioactivity. To maximize the theranostic potential of TEM1, we developed a panel of all human, multivalent Fc-fusion proteins based on a previously identified single chain antibody (scFv78) that recognizes both human and mouse TEM1. By characterizing avidity, stability, and pharmacokinectics, we identified one fusion protein, 78Fc, with desirable characteristics for immuno-imaging applications. The biodistribution of radiolabeled 78Fc showed that this antibody had minimal binding to normal organs, which have low expression of TEM1. Next, we developed a 78Fc-based tracer and tested its performance in different TEM1-expressing mouse models. The NIR imaging and tomography results suggest that the 78Fc-NIR tracer performs well in distinguishing mouse- or human-TEM1 expressing tumor grafts from normal organs and control grafts in vivo. From these results we conclude that further development and optimization of 78Fc as a TEM1-targeted imaging agent for use in clinical settings is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To better understand the structure of the Patient Assessment of Chronic Illness Care (PACIC) instrument. More specifically to test all published validation models, using one single data set and appropriate statistical tools. DESIGN: Validation study using data from cross-sectional survey. PARTICIPANTS: A population-based sample of non-institutionalized adults with diabetes residing in Switzerland (canton of Vaud). MAIN OUTCOME MEASURE: French version of the 20-items PACIC instrument (5-point response scale). We conducted validation analyses using confirmatory factor analysis (CFA). The original five-dimension model and other published models were tested with three types of CFA: based on (i) a Pearson estimator of variance-covariance matrix, (ii) a polychoric correlation matrix and (iii) a likelihood estimation with a multinomial distribution for the manifest variables. All models were assessed using loadings and goodness-of-fit measures. RESULTS: The analytical sample included 406 patients. Mean age was 64.4 years and 59% were men. Median of item responses varied between 1 and 4 (range 1-5), and range of missing values was between 5.7 and 12.3%. Strong floor and ceiling effects were present. Even though loadings of the tested models were relatively high, the only model showing acceptable fit was the 11-item single-dimension model. PACIC was associated with the expected variables of the field. CONCLUSIONS: Our results showed that the model considering 11 items in a single dimension exhibited the best fit for our data. A single score, in complement to the consideration of single-item results, might be used instead of the five dimensions usually described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The choice of design between individual randomisation, cluster or pseudo-cluster randomisation is often made difficult. Clear methodological guidelines have been given for trials in general practice, but not for vaccine trials. This article proposes a decisional flow-chart to choose the most adapted design for evaluating the effectiveness of a vaccine in large-scale studies. Six criteria have been identified: importance of herd immunity or herd protection, ability to delimit epidemiological units, homogeneity of transmission probability across sub-populations, population's acceptability of randomisation, availability of logistical resources, and estimated sample size. This easy to use decisional method could help sponsors, trial steering committees and ethical committees adopt the most suitable design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Childhood obesity and physical inactivity are increasing dramatically worldwide. Children of low socioeconomic status and/or children of migrant background are especially at risk. In general, the overall effectiveness of school-based programs on health-related outcomes has been disappointing. A special gap exists for younger children and in high risk groups. This paper describes the rationale, design, curriculum, and evaluation of a multicenter preschool randomized intervention study conducted in areas with a high migrant population in two out of 26 Swiss cantons. Twenty preschool classes in the German (canton St. Gallen) and another 20 in the French (canton Vaud) part of Switzerland were separately selected and randomized to an intervention and a control arm by the use of opaque envelopes. The multidisciplinary lifestyle intervention aimed to increase physical activity and sleep duration, to reinforce healthy nutrition and eating behaviour, and to reduce media use. According to the ecological model, it included children, their parents and the teachers. The regular teachers performed the majority of the intervention and were supported by a local health promoter. The intervention included physical activity lessons, adaptation of the built infrastructure; promotion of regional extracurricular physical activity; playful lessons about nutrition, media use and sleep, funny homework cards and information materials for teachers and parents. It lasted one school year. Baseline and post-intervention evaluations were performed in both arms. Primary outcome measures included BMI and aerobic fitness (20 m shuttle run test). Secondary outcomes included total (skinfolds, bioelectrical impedance) and central (waist circumference) body fat, motor abilities (obstacle course, static and dynamic balance), physical activity and sleep duration (accelerometry and questionnaires), nutritional behaviour and food intake, media use, quality of life and signs of hyperactivity (questionnaires), attention and spatial working memory ability (two validated tests). Researchers were blinded to group allocation. The purpose of this paper is to outline the design of a school-based multicenter cluster randomized, controlled trial aiming to reduce body mass index and to increase aerobic fitness in preschool children in culturally different parts of Switzerland with a high migrant population. Trial Registration: (clinicaltrials.gov) NCT00674544.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The hospital readmission rate has been proposed as an important outcome indicator computable from routine statistics. However, most commonly used measures raise conceptual issues. OBJECTIVES: We sought to evaluate the usefulness of the computerized algorithm for identifying avoidable readmissions on the basis of minimum bias, criterion validity, and measurement precision. RESEARCH DESIGN AND SUBJECTS: A total of 131,809 hospitalizations of patients discharged alive from 49 hospitals were used to compare the predictive performance of risk adjustment methods. A subset of a random sample of 570 medical records of discharge/readmission pairs in 12 hospitals were reviewed to estimate the predictive value of the screening of potentially avoidable readmissions. MEASURES: Potentially avoidable readmissions, defined as readmissions related to a condition of the previous hospitalization and not expected as part of a program of care and occurring within 30 days after the previous discharge, were identified by a computerized algorithm. Unavoidable readmissions were considered as censored events. RESULTS: A total of 5.2% of hospitalizations were followed by a potentially avoidable readmission, 17% of them in a different hospital. The predictive value of the screen was 78%; 27% of screened readmissions were judged clearly avoidable. The correlation between the hospital rate of clearly avoidable readmission and all readmissions rate, potentially avoidable readmissions rate or the ratio of observed to expected readmissions were respectively 0.42, 0.56 and 0.66. Adjustment models using clinical information performed better. CONCLUSION: Adjusted rates of potentially avoidable readmissions are scientifically sound enough to warrant their inclusion in hospital quality surveillance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) is a widely used, highly sensitive laboratory technique to rapidly and easily detect, identify and quantify gene expression. Reliable RT-qPCR data necessitates accurate normalization with validated control genes (reference genes) whose expression is constant in all studied conditions. This stability has to be demonstrated.We performed a literature search for studies using quantitative or semi-quantitative PCR in the rat spared nerve injury (SNI) model of neuropathic pain to verify whether any reference genes had previously been validated. We then analyzed the stability over time of 7 commonly used reference genes in the nervous system - specifically in the spinal cord dorsal horn and the dorsal root ganglion (DRG). These were: Actin beta (Actb), Glyceraldehyde-3-phosphate dehydrogenase (GAPDH), ribosomal proteins 18S (18S), L13a (RPL13a) and L29 (RPL29), hypoxanthine phosphoribosyltransferase 1 (HPRT1) and hydroxymethylbilane synthase (HMBS). We compared the candidate genes and established a stability ranking using the geNorm algorithm. Finally, we assessed the number of reference genes necessary for accurate normalization in this neuropathic pain model. RESULTS: We found GAPDH, HMBS, Actb, HPRT1 and 18S cited as reference genes in literature on studies using the SNI model. Only HPRT1 and 18S had been once previously demonstrated as stable in RT-qPCR arrays. All the genes tested in this study, using the geNorm algorithm, presented gene stability values (M-value) acceptable enough for them to qualify as potential reference genes in both DRG and spinal cord. Using the coefficient of variation, 18S failed the 50% cut-off with a value of 61% in the DRG. The two most stable genes in the dorsal horn were RPL29 and RPL13a; in the DRG they were HPRT1 and Actb. Using a 0.15 cut-off for pairwise variations we found that any pair of stable reference gene was sufficient for the normalization process. CONCLUSIONS: In the rat SNI model, we validated and ranked Actb, RPL29, RPL13a, HMBS, GAPDH, HPRT1 and 18S as good reference genes in the spinal cord. In the DRG, 18S did not fulfill stability criteria. The combination of any two stable reference genes was sufficient to provide an accurate normalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microsatellites are important highly polymorphic genetic markers dispersed in the human genome. Using a panel of 22 (CA)n repeat microsatellite markers mapped to recurrent breakpoint cluster regions specifically involved in leukemia, we investigated 114 adult leukemias (25 acute lymphocytic leukemia [ALL], 32 acute myeloid leukemia [AML], 36 chronic lymphocytic leukemia [CLL], and 21 chronic myeloid leukemia [CML] in chronic phase) for somatic mutations at these loci. In each patient, DNA from fresh leukemia samples was analyzed alongside normal constitutive DNA from buccal epithelium. We detected loss of heterozygosity (LOH) in 81 of 114 patients (ALL 16/25, AML 25/32, CLL 30/36, CML 10/21). Deletions were most often seen in ALL at 11q23 and 19p13; in AML at 8q22 and 11q23; in CLL at 13q14.3, 11q13, and 11q23; and in CML at 3q26. Only six deletions were reported in 74 karyotypes analyzed, whereas in these same cases, 91 LOH events were detected by microsatellites. Of 26 leukemias with a normal karyotype, 16 nevertheless showed at least one LOH by microsatellite analysis. Replication errors were found in 10 of 114 patients (8.8%). Thus, microsatellite instability is rare in leukemia in contrast to many solid tumors. Our findings suggest that in adult leukemia, LOH may be an important genetic event in addition to typical chromosomal translocations. LOH may point to the existence of tumor suppressor genes involved in leukemogenesis to a degree that has hitherto been underestimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Due to patency of the arterial duct and the parallel circulation during the fetal life, coarctation remains a difficult diagnosis prenatally and even shortly after birth. Fisrtly, our study aimed to assess accuracy of a new cardiographie index based on morphologie measurements of the distal aortic arch, the Carotid-Subclavian Artery Index (CSA Index), the ratio of the distal transverse aortic arch diameter to the distance between the left carotid artery and the left subclavian artery, in detecting coarctation in newborns, infants and children, independently of other cardiac lesions. Secondly, to assess the additive value of another morphologie index in predicting coarctation, the 1/0 ratio, the ratio of isthmus to descending aorta diameter. Methods: It is a retrospective cohort study in a tertiary care children's hospital. Offline echocardiographic measurements of great vessels and aortic arch dimensions were done in 69 patients with coarctation. We calculate their CSA index, and their 1/0 ratio. Values of CSA Index and 1/0 ratio from coarctation group were compared with those from a normal local control population. Results: 69 echocardiograms from patients with coarctation were analysed. Compared with controls, patients with coarctation had a significantly lower CSA index (0.88 ±0.49 vs 2.65 ±0.82, p <0.0001) and 1/0 ratio. The same significant difference was observed, independently of age and other associated defects, even complex ones. CSA Index confirmed its good sensitivity and specificity (99% and 96% respectively). This was not improved by adding the I/D ratio. Conclusions: An abnormal CSA index is highly suggestive of coarctation independently of age, of the presence of a patent ductus arteriosus or of other cardiac defects. The addition of another anatomie index, the I/D ratio, was not helpful in our study.