164 resultados para Surgical adhesive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors evaluated ten years of surgical reanimation in the University Centre of Lausanne (CHUV). Irreversible coagulopathy (IC) is the predominant cause of death for the polytraumatized patient. Acidosis, hypothermy, and coagulation troubles are crucial elements of this coagulopathy. The authors looked for a criterion allowing the identification of dying of IC. In a retrospective study, laboratory results of pH, TP, PTT, thrombocyte count and the need for blood transfusion units were checked for each major step of the primary evaluation and treatment of the polytraumatized patients. These results were considered as critical according to criteria of the literature (30). The authors conclude that the apparation of a third critical value may be useful to identify the polytraumatized patient at risk of dying of IC status. This criterion may also guide the trauma team in selecting a damage control surgical approach (DCS). This criterion was then introduced into an algorithm involving the Emergency Department, the operating room and the Intensive Care Unit. This criterion is a new tool to address the patient at the crucial moment to the appropriate hospital structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The use of virtual reality (VR) has gained increasing interest to acquire laparoscopic skills outside the operating theatre and thus increasing patients' safety. The aim of this study was to evaluate trainees' acceptance of VR for assessment and training during a skills course and at their institution. METHODS: All 735 surgical trainees of the International Gastrointestinal Surgery Workshop 2006-2008, held in Davos, Switzerland, were given a minimum of 45 minutes for VR training during the course. Participants' opinion on VR was analyzed with a standardized questionnaire. RESULTS: Fivehundred-twenty-seven participants (72%) from 28 countries attended the VR sessions and answered the questionnaires. The possibility of using VR at the course was estimated as excellent or good in 68%, useful in 21%, reasonable in 9% and unsuitable or useless in 2%. If such VR simulators were available at their institution, most course participants would train at least one hour per week (46%), two or more hours (42%) and only 12% wouldn't use VR. Similarly, 63% of the participants would accept to operate on patients only after VR training and 55% to have VR as part of their assessment. CONCLUSION: Residents accept and appreciate VR simulation for surgical assessment and training. The majority of the trainees are motivated to regularly spend time for VR training if accessible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:: Although the surgical treatment of full-thickness macular hole is well established, the utility of pars plana vitrectomy in the treatment of lamellar macular hole (LMH) remains less clear. The purpose of the study is to report functional results of surgical treatment of LMH associated with epiretinal membrane. METHODS:: Retrospective chart review of patients undergoing pars plana vitrectomy and peeling of epiretinal membrane and internal limiting membrane, with or without air or gas tamponade, for symptomatic LMH associated with epimacular membrane. RESULTS:: Forty-five eyes of 44 patients were operated for LMH associated with epimacular membrane between May 2000 and July 2009. Pars plana vitrectomy and membrane peeling were combined with air or gas tamponade in 43 of 45 cases. Mean logarithm of the minimum angle of resolution best-corrected visual acuity improved from 0.4 preoperatively to 0.13 postoperatively (P < 0.0001). Improvement in visual acuity ranged from 0 Early Treatment Diabetic Retinopathy Study (ETDRS) lines to 8.9 ETDRS lines (mean, 2.65 ETDRS lines). Visual acuity improved by ≥1 ETDRS line(s) in 40 of 45 eyes (89%) and by ≥2 ETDRS lines in 26 of 45 eyes (58%) after the surgical procedure. No patient lost vision. CONCLUSION:: This small retrospective study suggests that surgical treatment of LMH associated with epimacular membrane may improve visual acuity in symptomatic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 25-year-old male asylum-seeker presented with chest pain, exertional dyspnea, and orthopnea 20 years after the surgical repair of a pentalogy of Fallot. An extracardiac mass compressing the right ventricle was subsequently detected and surgical decompression was performed to relieve the resulting right intraventricular hypertension. At operation, the mass proved to be a coagulase-negative, staphylococcal abscess. In addition, the removal of the mass unmasked a previously nonrecognized pulmonary outflow stenosis that required balloon dilatation and beta-blocker therapy. While infections are known to occur after sternotomy, the formation of an abscess in the anterior mediastinum several years after the intervention appears to be exceptional; this diagnosis came to mind only after the more common complications had been considered, e.g., pseudoaneurysm or pericardial hematoma. To our knowledge, this is the first report of an abscess in the anterior mediastinum that had probably formed over many years following a sternotomy, compressed the right ventricle and masked a pulmonary stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical indications in spinal trauma remain a controversial topic. In general, unstable cervical injuries such as displaced odontoid fractures, burst fractures or tear drop fractures require surgical intervention. Thoracolumbar compression injuries without posterior wall involvement or significant kyphosis can be treated conservatively. Surgery is indicated in fractures-dislocations and burst fractures with significant canal narrowing and/or major kyphosis. The role of emergency decompression as well as that of steroids remain uncertain since no study to date has convincingly proven their efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Total orbital exenteration is a radical surgical procedure, which typically involves the removal of the entire contents of the orbit including the periorbita, leaving the patient with a deep orbital deformity and results in devastating cosmetic, functional, and psychological consequences requiring difficult and challenging procedures for oculoplastic surgeons. Oculofacial prostheses retained by endosseous dental implants present an attractive and viable alternative when aesthetic and functional demands are beyond the capacity of local reconstructive efforts. PATIENTS AND METHODS: A 72-year-old woman presenting a malignant melanoma of the right eyelids and a 77-year-old man presenting a sebaceous carcinoma of the left upper eyelid underwent a total exenteration followed by positioning of endosseous implants (Straumann system Dental implants) as an integrated one-step combined surgical procedure. The oculofacial prosthesis was placed after epithelialization of the orbital cavity. RESULTS: The implants were perfectly osseointegrated without any complications, providing sufficient retention of the prostheses. A satisfactory aesthetic outcome has been achieved for both patients. CONCLUSIONS: Oculofacial prostheses anchored by osseointegrated dental implants placed as one-step surgical procedure ensure an adequate aesthetic result as well as a considerably decreased rehabilitation time and present a satisfactory solution when reconstruction is not a suitable option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Roux-en-Y gastric bypass (RYGBP) is one of the commonest procedure for morbid obesity. It is associated with effective long-term weight loss, but can lead to significant complications, especially at the gastrojejunostomy (GJS) Patients and Methods: All the patients undergoing laparoscopic RYGBP at one of our two institutions were included in this study, in which we compared two different techniques for the construction of the GJS and their effects on the incidence of complications. In group A, anatomosis was performed on the posterior aspect of the gastric pouch. In group B it was performed across the staple line used to form the gastric pouch. A 21-mm circular stapler was used in all patients. Results: A total of 1128 patients were included between June 1999 and September 2009, 639 in group A and 488 in group B. Sixty patients developed a total of 65 complications at the GJS, with 14 (1,2 %) leaks, 42 (3,7 %) stricture, and 9 (0,8 %) marginal ulcers. Leaks (0,2 versus 2 %, p=0,005) and strictures (0,8 versus 5,9%, p<0,0001) were significantly fewer in group B than in group A. Conclusions: Improved surgical technique, with the GJS across the staple line used to form the gastric pouch, significantly reduces the rate of anastomotic complications at the GJS. A circular 21-mm stapler can be used with a low complication rate, and especially a low stricture rate. Additional methods to limit complications at the GJS are probably not routinely warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic low back pain attributed to lumbar disc degeneration poses a serious challenge to physicians. Surgery may be indicated in selected cases following failure of appropriate conservative treatment. For decades, the only surgical option has been spinal fusion, but its results have been inconsistent. Some prospective trials show superiority over usual conservative measures while others fail to demonstrate its advantages. In an effort to improve results of fusion and to decrease the incidence of adjacent segment degeneration, total disc replacement techniques have been introduced and studied extensively. Short-term results have shown superiority over some fusion techniques. Mid-term results however tend to show that this approach yields results equivalent to those of spinal fusion. Nucleus replacement has gained some popularity initially, but evidence on its efficacy is scarce. Dynamic stabilisation, a technique involving less rigid implants than in spinal fusion and performed without the need for bone grafting, represents another surgical option. Evidence again is lacking on its superiority over other surgical strategies and conservative measures. Insertion of interspinous devices posteriorly, aiming at redistributing loads and relieving pain, has been used as an adjunct to disc removal surgery for disc herniation. To date however, there is no clear evidence on their efficacy. Minimally invasive intradiscal thermocoagulation techniques have also been tried, but evidence of their effectiveness is questioned. Surgery using novel biological solutions may be the future of discogenic pain treatment. Collaboration between clinicians and basic scientists in this multidisciplinary field will undoubtedly shape the future of treating symptomatic disc degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The benefit of stress ulcer prophylaxis (SUP) in noncriticallyill patients has not been proved. Over-prescription of SUP isnot devoided of risks (i.e. drug-drug interactions, adverse events).This prospective study aimed to evaluate the use of proton pumpinhibitors (PPIs) for SUP in a visceral surgery ward.Materials & Methods Data collection was performed prospectivelyduring a 8-week period on patients hospitalized in a visceral surgeryward (58 beds). Patients with a PPI prescription for the treatment ofulcers, gastroesophageal reflux disease, esophagitis or epigastralgiawere excluded as well as patients hospitalized twice during the studyperiod. The American Society of Health-System Pharmacists guidelineson SUP were used to assess the appropriateness of de novo PPIprescriptions.Results Among 255 patients in the study, 138 (54.1%) received aprophylaxis with PPI, of which 86 (62.3%) were de novo PPI prescriptions.93.5% of patients received esomeprazole (according to thehospital drug formulary) mainly orally at 40 mg qd. 79.1% of patientshad no risk factors for SUP. 17.9% and 3.0% had one and two riskfactors, respectively. 95% of the patients with PPI were not hospitalizedin the intensive care unit (ICU) before their stay in the visceralsurgery ward. At discharge, PPI therapy was continued in 34.2% ofpatients with a de novo PPI prescription.Discussion & Conclusion This study highlights the over-utilizationof PPIs in non-ICU patients and the inappropriate continuation of PPIprescriptions at discharge. The PPI dosage prescribed for prophylaxiswas probably too high compared with the data of the literature.Treatment recommendations for SUP are needed to restrict PPIuse for justified indications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extended pharmacological venous thromboembolism (VTE) prophylaxis beyond discharge is recommended for patients undergoing high-risk surgery. We prospectively investigated prophylaxis in 1,046 consecutive patients undergoing major orthopaedic (70%) or major cancer surgery (30%) in 14 Swiss hospitals. Appropriate in-hospital prophylaxis was used in 1,003 (96%) patients. At discharge, 638 (61%) patients received prescription for extended pharmacological prophylaxis: 564 (77%) after orthopaedic surgery, and 74 (23%) after cancer surgery (p < 0.001). Patients with knee replacement (94%), hip replacement (81%), major trauma (80%), and curative arthroscopy (73%) had the highest prescription rates for extended VTE prophylaxis; the lowest rates were found in patients undergoing major surgery for thoracic (7%), gastrointestinal (19%), and hepatobiliary (33%) cancer. The median duration of prescribed extended prophylaxis was longer in patients with orthopaedic surgery (32 days, interquartile range 14-40 days) than in patients with cancer surgery (23 days, interquartile range 11-30 days; p<0.001). Among the 278 patients with an extended prophylaxis order after hip replacement, knee replacement, or hip fracture surgery, 120 (43%) received a prescription for at least 35 days, and among the 74 patients with an extended prophylaxis order after major cancer surgery, 20 (27%) received a prescription for at least 28 days. In conclusion, approximately one quarter of the patients with major orthopaedic surgery and more than three quarters of the patients with major cancer surgery did not receive prescription for extended VTE prophylaxis. Future effort should focus on the improvement of extended VTE prophylaxis, particularly in patients undergoing major cancer surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:: To assess the overall burden of healthcare-associated infections (HAIs) in patients exposed and nonexposed to surgery. BACKGROUND:: Targeted HAI surveillance is common in healthcare institutions, but may underestimate the overall burden of disease. METHODS:: Prevalence study among patients hospitalized in 50 acute care hospitals participating in the Swiss Nosocomial Infection Prevalence surveillance program. RESULTS:: Of 8273 patients, 3377 (40.8%) had recent surgery. Overall, HAI was present in 358 (10.6%) patients exposed to surgery, but only in 206 (4.2%) of 4896 nonexposed (P < 0.001). Prevalence of surgical site infection (SSI) was 5.4%. Healthcare-associated infections prevalence excluding SSI was 6.5% in patients with surgery and 4.7% in those without (P < 0.0001). Patients exposed to surgery carried less intrinsic risk factors for infection (age >60 years, 55.6% vs 63.0%; American Society of Anesthesiologists score >3, 5.9% vs 9.3%; McCabe for rapidly fatal disease, 3.9% vs 6.6%; Charlson comorbidity index >2, 12.3% vs 20.9%, respectively; all P < 0.001) than those nonexposed, but more extrinsic risk factors (urinary catheters, 39.6% vs 14.1%; central venous catheters, 17.8% vs 7.1%; mechanical ventilation, 4.7% vs 1.3%; intensive care stay, 18.3% vs 8.8%, respectively; all P < 0.001). Exposure to surgery independently predicted an increased risk of HAI (odds ratio 2.43; 95% CI 2.0-3.0). CONCLUSIONS:: Despite a lower intrinsic risk, patients exposed to surgery carried more than twice the overall HAI burden than those nonexposed; almost half was accountable to SSI. Extending infection control efforts beyond SSI prevention in these patients might be rewarding, especially because of the extrinsic nature of risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibrin glue products and collagen patches are frequently used as a sealing product, preventing surgical side bleedings. This is especially true in the field of cardiovascular surgery, where increasing numbers of patients are being operated with antiplatelet and anticoagulation therapy. The aim of this report was, in an in vitro hemodynamic setting, to examine the sealant properties of the TachoSil (Nycomed Pharma, Linz, Austria) patch. Burst pressure and normal force of 15 TachoSil sealed defects were measured. This was determined in a closed hydraulic system. Mean burst pressure load for a 5-mm defect was 69+/-11.4 mmHg; for a 7-mm defect was 63+/-16 mmHg; and, 62+/-16 mmHg for the defect with a diameter of 10 mm (P>0.05). The mean calculated normal force was as follows: 0.91+/-0.15 N for the 5 mm defect, 6.5+/-1.6 N for the 7 mm, and 8.1+/-0.75 N for the 10 mm defect. The TachoSil patch has the capability to seal small defects. However, at the larger defects the seal character was significantly reduced. These results suggest that the device may be a good alternative for hemostasis for small defects. The capacity to curtail or stop hemorrhage at the larger defects is unlikely.