121 resultados para MASS SPECTROMETRY, GAS PHASE ACIDITY, GAS PHASE BASICITY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Isotope ratio mass spectrometry (IRMS) has been used in numerous fields of forensic science in a source inference perspective. This review compiles the studies published on the application of isotope ratio mass spectrometry (IRMS) to the traditional fields of forensic science so far. It completes the review of Benson et al. [1] and synthesises the extent of knowledge already gathered in the following fields: illicit drugs, flammable liquids, human provenancing, microtraces, explosives and other specific materials (packaging tapes, safety matches, plastics, etc.). For each field, a discussion assesses the state of science and highlights the relevance of the information in a forensic context. Through the different discussions which mark out the review, the potential and limitations of IRMS, as well as the needs and challenges of future studies are emphasized. The paper elicits the various dimensions of the source which can be obtained from the isotope information and demonstrates the transversal nature of IRMS as a tool for source inference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30ng/mL and 21ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies show that the composition of fingerprint residue varies significantly from the same donor as well as between donors. This variability is a major drawback in latent print dating issues. This study aimed, therefore, at the definition of a parameter that is less variable from print to print, using a ratio of peak area of a target compound degrading over time divided by the summed area of peaks of more stable compounds also found in latent print residues.Gas chromatography-mass spectrometry (GC/MS) analysis of the initial lipid composition of latent prints identifies four main classes of compounds that can be used in the definition of an aging parameter: fatty acids, sterols, sterol precursors, and wax esters (WEs). Although the entities composing the first three groups are quite well known, those composing WEs are poorly reported. Therefore, the first step of the present work was to identify WE compounds present in latent print residues deposited by different donors. Of 29 WEs recorded in the chromatograms, seven were observed in the majority of samples.The identified WE compounds were subsequently used in the definition of ratios in combination with squalene and cholesterol to reduce the variability of the initial composition between latent print residues from different persons and more particularly from the same person. Finally, the influence of a latent print enhancement process on the initial composition was studied by analyzing traces after treatment with magnetic powder, 1,2-indanedione, and cyanoacrylate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is focused on the development of a methodology for the use of chemical characteristic of tire traces to help answer the following question: "Is the offending tire at the origin of the trace found on the crime scene?". This methodology goes from the trace sampling on the road to statistical analysis of its chemical characteristics. Knowledge about the composition and manufacture of tread tires as well as a review of instrumental techniques used for the analysis of polymeric materials were studied to select, as an ansi vi cal technique for this research, pyrolysis coupled to a gas Chromatograph with a mass spectrometry detector (Py-GC/MS). An analytical method was developed and optimized to obtain the lowest variability between replicates of the same sample. Within-variability of the tread was evaluated regarding width and circumference with several samples taken from twelve tires of different brands and/or models. The variability within each of the treads (within-variability) and between the treads (between-variability) could be quantified. Different statistical methods have shown that within-variability is lower than between-variability, which helped differentiate these tires. Ten tire traces were produced with tires of different brands and/or models by braking tests. These traces have been adequately sampled using sheets of gelatine. Particles of each trace were analysed using the same methodology as for the tires at their origin. The general chemical profile of a trace or of a tire has been characterized by eighty-six compounds. Based on a statistical comparison of the chemical profiles obtained, it has been shown that a tire trace is not differentiable from the tire at its origin but is generally differentiable from tires that are not at its origin. Thereafter, a sample containing sixty tires was analysed to assess the discrimination potential of the developed methodology. The statistical results showed that most of the tires of different brands and models are differentiable. However, tires of the same brand and model with identical characteristics, such as country of manufacture, size and DOT number, are not differentiable. A model, based on a likelihood ratio approach, was chosen to evaluate the results of the comparisons between the chemical profiles of the traces and tires. The methodology developed was finally blindly tested using three simulated scenarios. Each scenario involved a trace of an unknown tire as well as two tires possibly at its origin. The correct results for the three scenarios were used to validate the developed methodology. The different steps of this work were useful to collect the required information to test and validate the underlying assumption that it is possible to help determine if an offending tire » or is not at the origin of a trace, by means of a statistical comparison of their chemical profile. This aid was formalized by a measure of the probative value of the evidence, which is represented by the chemical profile of the trace of the tire. - Ce travail s'est proposé de développer une méthodologie pour l'exploitation des caractéristiques chimiques des traces de pneumatiques dans le but d'aider à répondre à la question suivante : «Est-ce que le pneumatique incriminé est ou n'est pas à l'origine de la trace relevée sur les lieux ? ». Cette méthodologie s'est intéressée du prélèvement de la trace de pneumatique sur la chaussée à l'exploitation statistique de ses caractéristiques chimiques. L'acquisition de connaissances sur la composition et la fabrication de la bande de roulement des pneumatiques ainsi que la revue de techniques instrumentales utilisées pour l'analyse de matériaux polymériques ont permis de choisir, comme technique analytique pour la présente recherche, la pyrolyse couplée à un chromatographe en phase gazeuse avec un détecteur de spectrométrie de masse (Py-GC/MS). Une méthode analytique a été développée et optimisée afin d'obtenir la plus faible variabilité entre les réplicas d'un même échantillon. L'évaluation de l'intravariabilité de la bande de roulement a été entreprise dans sa largeur et sa circonférence à l'aide de plusieurs prélèvements effectués sur douze pneumatiques de marques et/ou modèles différents. La variabilité au sein de chacune des bandes de roulement (intravariabilité) ainsi qu'entre les bandes de roulement considérées (intervariabilité) a pu être quantifiée. Les différentes méthodes statistiques appliquées ont montré que l'intravariabilité est plus faible que l'intervariabilité, ce qui a permis de différencier ces pneumatiques. Dix traces de pneumatiques ont été produites à l'aide de pneumatiques de marques et/ou modèles différents en effectuant des tests de freinage. Ces traces ont pu être adéquatement prélevées à l'aide de feuilles de gélatine. Des particules de chaque trace ont été analysées selon la même méthodologie que pour les pneumatiques à leur origine. Le profil chimique général d'une trace de pneumatique ou d'un pneumatique a été caractérisé à l'aide de huitante-six composés. Sur la base de la comparaison statistique des profils chimiques obtenus, il a pu être montré qu'une trace de pneumatique n'est pas différenciable du pneumatique à son origine mais est, généralement, différenciable des pneumatiques qui ne sont pas à son origine. Par la suite, un échantillonnage comprenant soixante pneumatiques a été analysé afin d'évaluer le potentiel de discrimination de la méthodologie développée. Les méthodes statistiques appliquées ont mis en évidence que des pneumatiques de marques et modèles différents sont, majoritairement, différenciables entre eux. La méthodologie développée présente ainsi un bon potentiel de discrimination. Toutefois, des pneumatiques de la même marque et du même modèle qui présentent des caractéristiques PTD (i.e. pays de fabrication, taille et numéro DOT) identiques ne sont pas différenciables. Un modèle d'évaluation, basé sur une approche dite du likelihood ratio, a été adopté pour apporter une signification au résultat des comparaisons entre les profils chimiques des traces et des pneumatiques. La méthodologie mise en place a finalement été testée à l'aveugle à l'aide de la simulation de trois scénarios. Chaque scénario impliquait une trace de pneumatique inconnue et deux pneumatiques suspectés d'être à l'origine de cette trace. Les résultats corrects obtenus pour les trois scénarios ont permis de valider la méthodologie développée. Les différentes étapes de ce travail ont permis d'acquérir les informations nécessaires au test et à la validation de l'hypothèse fondamentale selon laquelle il est possible d'aider à déterminer si un pneumatique incriminé est ou n'est pas à l'origine d'une trace, par le biais d'une comparaison statistique de leur profil chimique. Cette aide a été formalisée par une mesure de la force probante de l'indice, qui est représenté par le profil chimique de la trace de pneumatique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 2004, cannabis has been prohibited by the World Anti-Doping Agency for all sports competitions. In the years since then, about half of all positive doping cases in Switzerland have been related to cannabis consumption. In doping urine analysis, the target analyte is 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), the cutoff being 15 ng/mL. However, the wide urinary detection window of the long-term metabolite of Delta(9)-tetrahydrocannabinol (THC) does not allow a conclusion to be drawn regarding the time of consumption or the impact on the physical performance. The purpose of the present study on light cannabis smokers was to evaluate target analytes with shorter urinary excretion times. Twelve male volunteers smoked a cannabis cigarette standardized to 70 mg THC per cigarette. Plasma and urine were collected up to 8 h and 11 days, respectively. Total THC, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and THC-COOH were determined after hydrolysis followed by solid-phase extraction and gas chromatography/mass spectrometry. The limits of quantitation were 0.1-1.0 ng/mL. Eight puffs delivered a mean THC dose of 45 mg. Plasma levels of total THC, THC-OH, and THC-COOH were measured in the ranges 0.2-59.1, 0.1-3.9, and 0.4-16.4 ng/mL, respectively. Peak concentrations were observed at 5, 5-20, and 20-180 min. Urine levels were measured in the ranges 0.1-1.3, 0.1-14.4, and 0.5-38.2 ng/mL, peaking at 2, 2, and 6-24 h, respectively. The times of the last detectable levels were 2-8, 6-96, and 48-120 h. Besides high to very high THC-COOH levels (245 +/- 1,111 ng/mL), THC (3 +/- 8 ng/mL) and THC-OH (51 +/- 246 ng/mL) were found in 65 and 98% of cannabis-positive athletes' urine samples, respectively. In conclusion, in addition to THC-COOH, the pharmacologically active THC and THC-OH should be used as target analytes for doping urine analysis. In the case of light cannabis use, this may allow the estimation of more recent consumption, probably influencing performance during competitions. However, it is not possible to discriminate the intention of cannabis use, i.e., for recreational or doping purposes. Additionally, pharmacokinetic data of female volunteers are needed to interpret cannabis-positive doping cases of female athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Totalp-Platta-Malenco ophiolites in the Eastern Central Alps offer a unique opportunity to study the behaviour of Li, Be and B in ultramafic rocks in response to serpentinization and to progressive Alpine metamorphism. These units represent the remnants of a former ocean-continent transition that was intensely serpentinized during exposure on the Jurassic seafloor of the Ligurian Tethys. From north to the south, three isograd reactions (lizardite double right arrow antigorite + brucite; lizardite + talc double right arrow antigorite; lizardite + tremolite double right arrow antigorite + diopside) have been used to quantify the evolution of the light element content of metamorphic minerals. We determined the Li, Be and B concentrations in major silicate minerals from the ultramafic bodies of Totalp, Platta and Malenco by secondary ion mass spectrometry. Mantle minerals have Be concentrations (e.g. <0.001-0.009 mu g/g in olivine) similar to the metamorphic minerals that replace them (e.g. <0.001-0.016 mu g/g in serpentine). The mantle signature of Be is thus neither erased during seafloor alteration nor by progressive metamorphism from prehnite-pumpellyite to epidote-amphibolite facies. In contrast, the Li and B inventories of metamorphic minerals are related to the lizardite-to-antigorite transition. Both elements display higher concentrations in the low-temperature serpentine polymorph lizardite (max. 156 mu/g Li, max. 318 mu g/g B) than in antigorite (max. 0.11 mu g/g Li, max. 12 mu g/g B). Calculated average B/Li ratios for lizardite (similar to 1395) and antigorite (similar to 115) indicate that Li fractionates from B during the lizardite-to-antigorite transition during prograde metamorphism in ultramafic rocks. In subduction zones, this signature is likely to be recorded in the B-rich nature of forearc fluids. Relative to oceanic mantle the Be content of mantle clinopyroxene is much higher, but similar to Be values from mantle xenoliths and subduction-related peridotite massifs. These data support previous hypothesis that the mantle rocks from the Eastern Central Alps have a subcontinental origin. We conclude that Be behaves conservatively during subduction metamorphism of ultramafic rocks, at least at low-temperature, and thus retains the fingerprint of ancient subduction-related igneous events in mantle peridotites. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. However, hydrogen (H2) detection after a GC separation is only possible with a Thermal Conductivity Detector (TCD), a Helium Ionisation Detector (HID) or expensive Atomic Emission Detector (AED). Recently, indirect H2 detection by GC coupled to mass spectrometry (MS) was demonstrated but the mechanism of carrier gas protonation remained unclear. With electron impact as ionisation source of MS and helium (He) as GC carrier gas, H2 is not ionised according the expected Penning ionisation neither according to the Associative ionisation. Rearrangement ionisation (RI) was found to be the main channel for H2 and D2 ionisation under GC-MS conditions used in most of laboratories using GC-MS, leading to the formation of [He−H]+ and [He−D]+ ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Citalopram, a new bicyclic antidepressant, is the most selective serotonin reuptake inhibitor. In a number of double-blind controlled studies, citalopram was compared to placebo and to known tricyclic antidepressants. These studies have shown their efficacy and good safety. The inefficacy of a psychotropic treatment in at least 20% of depressives has led a number of authors to propose original drug combinations and associations, like antidepressant/lithium (Li), antidepressant/sleep deprivation (agrypnia), antidepressant/ECT, or antidepressant/LT3. The aim of this investigation is to evaluate the clinical effectiveness and safety of a combined citalopram/lithium treatment in therapy-resistant patients, taking account of serotonergic functions, as tested by the fenfluramine/prolactin test, and of drug pharmacokinetics and pharmacogenetics of metabolism. DESIGN OF THE STUDY: A washout period of 3 days before initiating the treatment is included. After an open treatment phase of 28 days (D) with citalopram (20 mg D1-D3; 40 mg D4-D14; 40 or 60 mg D15-D28; concomitant medication allowed: chloral, chlorazepate), the nonresponding patients [less than 50% improvement in the total score on the 21 item-Hamilton Depression Rating Scale (HDRS)] are selected and treated with or without Li (randomized in double-blind conditions: citalopram/Li or citalopram/placebo) during the treatment (D29-D35). Thereafter, all patients included in the double-blind phase subsequently receive an open treatment with citalopram/Li for 7 days (D36-D42). The hypothesis of a relationship between serotoninergic functions in patients using the fenfluramine/prolactin test (D1) and the clinical response to citalopram (and Li) is assessed. Moreover, it is evaluated whether the pharmacogenetic status of the patients, as determined by the mephenytoin/dextromethorphan test (D0-D28), is related to the metabolism of fenfluramine and citalopram, and also to the clinical response. CLINICAL ASSESSMENT: Patients with a diagnosis of major depressive disorders according to DSM III are submitted to a clinical assessment of D1, D7, D14, D28, D35, D42: HDRS, CGI (clinical global impression), VAS (visual analog scales for self-rating of depression), HDRS (Hamilton depression rating scale, 21 items), UKU (side effects scale), and to clinical laboratory examens, as well as ECG, control of weight, pulse, blood pressure at D1, D28, D35. Fenfluramine/prolactin test: A butterfly needle is inserted in a forearm vein at 7 h 45 and is kept patent with liquemine. Samples for plasma prolactin, and d- and l-fenfluramine determinations are drawn at 8 h 15 (base line). Patients are given 60 mg fenfluramine (as a racemate) at 8 h 30. Kinetic points are determined at 9 h 30, 10 h 30, 11 h 30, 12 h 30, 13 h 30. Plasma levels of d- and l-fenfluramine are determined by gas chromatography and prolactin by IRNA. Mephenytoin/dextromethorphan test: Patients empty their bladders before the test; they are then given 25 mg dextropethorphan and 100 mg mephenytoin (as a racemate) at 8 h 00. They collect all urines during the following 8 hours. The metabolic ratio is determined by gas chromatography (metabolic ratio dextromethorphan/dextrorphan greater than 0.3 = PM (poor metabolizer); mephenytoin/4-OH-mephenytoin greater than 5.6, or mephenytoin S/R greater than 0.8 = PM). Citalopram plasma levels: Plasma levels of citalopram, desmethylcitalopram and didesmethylcitalopram are determined by gas chromatography--mass spectrometry. RESULTS OF THE PILOT STUDY. The investigation has been preceded by a pilot study including 14 patients, using the abovementioned protocol, except that all nonresponders were medicated with citalopram/Li on D28 to D42. The mean total score (n = 14) on the 21 item Hamilton scale was significantly reduced after the treatment, ie from 26.93 +/- 5.80 on D1 to 8.57 +/- 6.90 on D35 (p less than 0.001). A similar patCitalopram, a new bicyclic antidepressant, is the most selective serotonin reu

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stimulants are banned in-competition for all categories of sports by the World Anti-Doping Agency. A simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay employing electrospray ionisation in positive mode was developed in that work for the quantification in urine specimens of 4-methyl-2-hexaneamine, a primary amine exhibiting sympathomimetic properties. Following a simple pretreatment procedure, the analyte was separated using a gradient mobile phase on reverse phase C8 column. Selected reaction monitoring m/z 116.2-->57.3 was specific for detection of 4-methyl-2-hexaneamine and the assay exhibited a linear dynamic range of 50-700 ng/mL. The validated method has been successfully applied to analyze the target compound in food supplements as well as in urine specimens. The administered drug (40 mg) was detected at the level of 350 ng/mL in the urine up to 4 days.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'exposition aux poussières de bois est associé à un risque accru d'adénocarcinomes des fosses nasales et des sinus paranasaux (SNC, 'Sinonasal cancer') chez les travailleurs du bois. Les poussières de bois sont ainsi reconnues comme cancérogènes avérés pour l'homme par le Centre international de Recherche sur le Cancer (CIRC). Toutefois, l'agent causal spécifique et le mécanisme sous-jacent relatifs au cancer lié aux poussières de bois demeurent inconnus. Une possible explication est une co-exposition aux poussières de bois et aux Hydrocarbures Aromatiques Polycycliques (HAP), ces derniers étant potentiellement cancérogènes. Dans les faits, les travailleurs du bois sont non seulement exposés aux poussières de bois naturel, mais également à celles générées lors d'opérations effectuées à l'aide de machines (ponceuses, scies électriques, etc.) sur des finitions de bois (bois traités) ou sur des bois composites, tels que le mélaminé et les panneaux de fibres à densité moyenne (MDF, 'Medium Density Fiberboard'). Des HAP peuvent en effet être générés par la chaleur produite par l'utilisation de ces machines sur la surface du bois. Les principaux objectifs de cette thèse sont les suivants: (1) quantifier HAP qui sont présents dans les poussières générées lors de diverses opérations courantes effectuées sur différents bois (2) quantifier l'exposition individuelle aux poussières de bois et aux HAP chez les travailleurs, et (3) évaluer les effets génotoxiques (dommages au niveau de l'ADN et des chromosomes) due à l'exposition aux poussières de bois et aux HAP. Cette thèse est composée par une étude en laboratoire (objectif 1) et par une étude de terrain (objectifs 2 et 3). Pour l'étude en laboratoire, nous avons collecté des poussières de différents type de bois (sapin, MDF, hêtre, sipo, chêne, bois mélaminé) générées au cours de différentes opérations (comme le ponçage et le sciage), et ceci dans une chambre expérimentale et dans des conditions contrôlées. Ensuite, pour l'étude de terrain, nous avons suivi, dans le cadre de leur activité professionnelle, 31 travailleurs de sexe masculin (travailleurs du bois et ébenistes) exposés aux poussières de bois pendant deux jours de travail consécutifs. Nous avons également recruté, comme groupe de contrôle, 19 travailleurs non exposés. Pour effectuer une biosurveillance, nous avons collecté des échantillons de sang et des échantillons de cellules nasales et buccales pour chacun des participants. Ces derniers ont également rempli un questionnaire comprenant des données démographiques, ainsi que sur leur style de vie et sur leur exposition professionnelle. Pour les travailleurs du bois, un échantillonnage individuel de poussière a été effectué sur chaque sujet à l'aide d'une cassette fermée, puis nous avons évalué leur exposition à la poussière de bois et aux HAP, respectivement par mesure gravimétrique et par Chromatographie en phase gazeuse combinée à la spectrométrie de masse. L'évaluation des dommages induits à l'ADN et aux chromosomes (génotoxicité) a été, elle, effectuée à l'aide du test des micronoyaux (MN) sur les cellules nasales et buccales et à l'aide du test des comètes sur les échantillons de sang. Nos résultats montrent dans la poussière de la totalité des 6 types de bois étudiés la présence de HAP (dont certains sont cancérogènes). Des différences notoires dans les concentrations ont été néanmoins constatées en fonction du matériau étudié : les concentrations allant de 0,24 ppm pour la poussière de MDF à 7.95 ppm pour le mélaminé. Nos résultats montrent également que les travailleurs ont été exposés individuellement à de faibles concentrations de HAP (de 37,5 à 119,8 ng m-3) durant les opérations de travail du bois, alors que les concentrations de poussières inhalables étaient relativement élevés (moyenne géométrique de 2,8 mg m-3). En ce qui concerne la génotoxicité, les travailleurs exposés à la poussière de bois présentent une fréquence significativement plus élevée en MN dans les cellules nasales et buccales que les travailleurs du groupe témoin : un odds ratio de 3.1 a été obtenu pour les cellules nasales (IC 95% : de 1.8 à 5.1) et un odds ratio de 1,8 pour les cellules buccales (IC 95% : de 1.3 à 2.4). En outre, le test des comètes a montré que les travailleurs qui ont déclaré être exposés aux poussières de MDF et/ou de mélaminé avaient des dommages à l'ADN significativement plus élevés que les deux travailleurs exposés à la poussière de bois naturel (sapin, épicéa, hêtre, chêne) et que les travailleurs du groupe témoin (p <.01). Enfin, la fréquence des MN dans les cellules nasales et buccales augmentent avec les années d'exposition aux poussières de bois. Par contre, il n'y a pas de relation dose-réponse concernant la génotoxicité due à l'exposition journalière à la poussière et aux HAP. Cette étude montre qu'une exposition aux HAP eu bien lieu lors des opérations de travail du bois. Les travailleurs exposés aux poussières de bois, et donc aux HAP, courent un risque plus élevé (génotoxicité) par rapport au groupe témoin. Étant donné que certains des HAP détectés sont reconnus potentiellement cancérogènes, il est envisageable que les HAP générés au cours du travail sur les matériaux de bois sont un des agents responsables de la génotoxicité de la poussière de bois et du risque élevé de SNC observé chez les travailleurs du secteur. Etant donné la corrélation entre augmentation de la fréquence des MN, le test des micronoyaux dans les cellules nasales et buccales constitue sans conteste un futur outil pour la biosurveillance et pour la détection précoce du risque de SNC chez les travailleurs. - Exposures to wood dust have been associated with an elevated risk of adenocarcinomas of the Dasal cavity and the paranasal sinuses (sinonasal cancer or SNC) among wood workers. Wood dust is recognized as a human carcinogen by the International Agency for Research on Cancer. However, the specific cancer causative agent(s) and the mechanism(s) behind wood dust related carcinogenesis remains unknown. One possible explanation is a co-exposure to wood dust and polycyclic aromatic hydrocarbons (PAH), the latter being carcinogenic. In addition, wood workers are not only exposed to natural wood but also to wood finishes and composite woods such as wood melamine and medium density fiber (MDF) boards during the manipulation with power tools. The heat produced by the use of power tools can cause the generation of PAH from wood materials. The main objectives of the present thesis are to: (1) quantify possible PAH concentrations in wood dust generated during various common woodworking operations using different wood materials; (2) quantify personal wood dust concentrations and PAH exposures among wood workers; and (3) assess genotoxic effects (i.e., DNA and chromosomal damage) of wood dust and PAH exposure in wood workers. This thesis is composed by a laboratory study (objective 1) and a field study (objectives 2 and 3). In the laboratory study we collected wood dust from different wood materials (fir, MDF, beech, mahagany, oak, and wood melamine) generated during different wood operations (e.g., sanding and sawing) in an experimental chamber under controlled conditions. In the following field study, we monitored 31 male wood workers (furniture and construction workers) exposed to wood dust during their professional activity for two consecutive work shifts. Additionally, we recruited 19 non exposed workers as a control group. We collected from each participant blood samples, and nasal and buccal cell samples. They answered a questionnaire including demographic and life-style data and occupational exposure (current and past). Personal wood dust samples were collected using a closed-face cassette. We used gravimetrie analysis to determine the personal wood dust concentrations and capillary gas chromatography - mass spectrometry analysis to determine PAH concentrations. Genotoxicity was assessed with the micronucleus (MN) assay for nasal and buccal cells and with the comet assay for blood samples. Our results show that PAH (some of them carcinogenic) were present in dust from all six wood materials tested, yet at different concentrations depending on the material. The highest concentration was found in dust from wood melamine (7.95 ppm) and the lowest in MDF (0.24 ppm). Our results also show that workers were individually exposed to low concentrations of PAHs (37.5-119.8 ng m"3) during wood working operations, whereas the concentrations of inhalable dust were relatively high (geometric mean 2.8 mg m"3). Concerning the genotoxicity, wood workers had a significantly higher MN frequency in nasal and buccal cells than the workers in the control group (odds ratio for nasal cells 3.1 (95%CI 1.8-5.1) and buccal cells 1.8 (95%CI 1.3-2.4)). Furthermore, the comet assay showed that workers who reported to be exposed to dust from wooden boards (MDF and wood melamine) had significantly higher DNA damage than both the workers exposed to natural woods (fir, spruce, beech, oak) and the workers in the control group (p < 0.01). Finally, MN frequency in nasal and buccal cells increased with increasing years of exposure to wood dust. However, there was no genotoxic dose-response relationship with the per present day wood dust and PAH exposure. This study shows that PAH exposure occurred during wood working operations. Workers exposed to wood dust, and thus to PAH, had a higher risk for genotoxicity compared to the control group. Since some of the detected PAH are potentially carcinogenic, PAH generated from operations on wood materials may be one of the causative agents for the observed increased genotoxicity in wood workers. Since increased genotoxicity is manifested in an increased MN frequency, the MN assay in nasal and buccal cells may become a relevant biomonitoring tool in the future for early detection of SNC risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.