245 resultados para Integration testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Replicative phenotypic HIV resistance testing (rPRT) uses recombinant infectious virus to measure viral replication in the presence of antiretroviral drugs. Due to its high sensitivity of detection of viral minorities and its dissecting power for complex viral resistance patterns and mixed virus populations rPRT might help to improve HIV resistance diagnostics, particularly for patients with multiple drug failures. The aim was to investigate whether the addition of rPRT to genotypic resistance testing (GRT) compared to GRT alone is beneficial for obtaining a virological response in heavily pre-treated HIV-infected patients. METHODS: Patients with resistance tests between 2002 and 2006 were followed within the Swiss HIV Cohort Study (SHCS). We assessed patients' virological success after their antiretroviral therapy was switched following resistance testing. Multilevel logistic regression models with SHCS centre as a random effect were used to investigate the association between the type of resistance test and virological response (HIV-1 RNA <50 copies/mL or ≥1.5 log reduction). RESULTS: Of 1158 individuals with resistance tests 221 with GRT+rPRT and 937 with GRT were eligible for analysis. Overall virological response rates were 85.1% for GRT+rPRT and 81.4% for GRT. In the subgroup of patients with >2 previous failures, the odds ratio (OR) for virological response of GRT+rPRT compared to GRT was 1.45 (95% CI 1.00-2.09). Multivariate analyses indicate a significant improvement with GRT+rPRT compared to GRT alone (OR 1.68, 95% CI 1.31-2.15). CONCLUSIONS: In heavily pre-treated patients rPRT-based resistance information adds benefit, contributing to a higher rate of treatment success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to practical difficulties in obtaining direct genetic estimates of effective sizes, conservation biologists have to rely on so-called 'demographic models' which combine life-history and mating-system parameters with F-statistics in order to produce indirect estimates of effective sizes. However, for the same practical reasons that prevent direct genetic estimates, the accuracy of demographic models is difficult to evaluate. Here we use individual-based, genetically explicit computer simulations in order to investigate the accuracy of two such demographic models aimed at investigating the hierarchical structure of populations. We show that, by and large, these models provide good estimates under a wide range of mating systems and dispersal patterns. However, one of the models should be avoided whenever the focal species' breeding system approaches monogamy with no sex bias in dispersal or when a substructure within social groups is suspected because effective sizes may then be strongly overestimated. The timing during the life cycle at which F-statistics are evaluated is also of crucial importance and attention should be paid to it when designing field sampling since different demographic models assume different timings. Our study shows that individual-based, genetically explicit models provide a promising way of evaluating the accuracy of demographic models of effective size and delineate their field of applicability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The question of where retroviral DNA becomes integrated in chromosomes is important for understanding (i) the mechanisms of viral growth, (ii) devising new anti-retroviral therapy, (iii) understanding how genomes evolve, and (iv) developing safer methods for gene therapy. With the completion of genome sequences for many organisms, it has become possible to study integration targeting by cloning and sequencing large numbers of host-virus DNA junctions, then mapping the host DNA segments back onto the genomic sequence. This allows statistical analysis of the distribution of integration sites relative to the myriad types of genomic features that are also being mapped onto the sequence scaffold. Here we present methods for recovering and analyzing integration site sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic polymorphisms have currently been described in more than 200 systems affecting pharmacological responses (cytochromes P450, conjugation enzymes, transporters, receptors, effectors of response, protection mechanisms, determinants of immunity). Pharmacogenetic testing, i.e. the profiling of individual patients for such variations, is about to become largely available. Recent progress in the pharmacogenetics of tamoxifen, oral anticoagulants and anti-HIV agents is reviewed to discuss critically their potential impact on prescription and contribution/limits for improving rational and safe use of pharmaceuticals. Prospective controlled trials are required to evaluate large-scale pharmacogenetic testing in therapeutics. Ethical, social and psychological issues deserve particular attention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Accurate characterization of the spatial distribution of hydrological properties in heterogeneous aquifers at a range of scales is a key prerequisite for reliable modeling of subsurface contaminant transport, and is essential for designing effective and cost-efficient groundwater management and remediation strategies. To this end, high-resolution geophysical methods have shown significant potential to bridge a critical gap in subsurface resolution and coverage between traditional hydrological measurement techniques such as borehole log/core analyses and tracer or pumping tests. An important and still largely unresolved issue, however, is how to best quantitatively integrate geophysical data into a characterization study in order to estimate the spatial distribution of one or more pertinent hydrological parameters, thus improving hydrological predictions. Recognizing the importance of this issue, the aim of the research presented in this thesis was to first develop a strategy for the assimilation of several types of hydrogeophysical data having varying degrees of resolution, subsurface coverage, and sensitivity to the hydrologic parameter of interest. In this regard a novel simulated annealing (SA)-based conditional simulation approach was developed and then tested in its ability to generate realizations of porosity given crosshole ground-penetrating radar (GPR) and neutron porosity log data. This was done successfully for both synthetic and field data sets. A subsequent issue that needed to be addressed involved assessing the potential benefits and implications of the resulting porosity realizations in terms of groundwater flow and contaminant transport. This was investigated synthetically assuming first that the relationship between porosity and hydraulic conductivity was well-defined. Then, the relationship was itself investigated in the context of a calibration procedure using hypothetical tracer test data. Essentially, the relationship best predicting the observed tracer test measurements was determined given the geophysically derived porosity structure. Both of these investigations showed that the SA-based approach, in general, allows much more reliable hydrological predictions than other more elementary techniques considered. Further, the developed calibration procedure was seen to be very effective, even at the scale of tomographic resolution, for predictions of transport. This also held true at locations within the aquifer where only geophysical data were available. This is significant because the acquisition of hydrological tracer test measurements is clearly more complicated and expensive than the acquisition of geophysical measurements. Although the above methodologies were tested using porosity logs and GPR data, the findings are expected to remain valid for a large number of pertinent combinations of geophysical and borehole log data of comparable resolution and sensitivity to the hydrological target parameter. Moreover, the obtained results allow us to have confidence for future developments in integration methodologies for geophysical and hydrological data to improve the 3-D estimation of hydrological properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Since the advent of combined antiretroviral therapy (ART), the incidence of non-AIDS-defining cancers (non-ADCs) among HIV-positive patients is rising. We previously described HIV testing rates of <5% in our oncology centre, against a local HIV prevalence of 0.4% (1). We have since worked with the Service of Oncology to identify, how HIV testing can be optimized, we have conducted a study on investigating barriers in HIV-testing oncology patients (IBITOP) among treating oncologists and their patients. METHODS: After an initial two-month pilot study to examine feasibility (2), we conducted the first phase of the IBITOP study between 1st July and 31st October 2013. Patients of unknown HIV status, newly diagnosed with solid-organ non-AIDS-defining cancer, and treated at Lausanne University Hospital were invited to participate. Patients were offered HIV testing as a part of their initial oncology work-up. Oncologist testing proposals and patient acceptance were the primary endpoints. RESULTS: Of 235 patients with a new oncology diagnosis, 10 were excluded (7 with ADCs and 3 of known HIV-positive status). Mean age was 62 years; 48% were men and 71% were Swiss. Of 225 patients, 75 (33%) were offered HIV testing. Of these, 56 (75%) accepted, of whom 52 (93%) were tested. A further ten patients were tested (without documentation of being offered a test), which gave a total testing rate of 28% (62/225). Among the 19 patients who declined testing, reasons cited included self-perceived absence of HIV risk, previous testing and palliative care. Of the 140 patients not offered HIV testing and not tested, reasons were documented for 35 (25%), the most common being previous testing and follow-up elsewhere. None of the 62 patients HIV tested had a reactive test. CONCLUSIONS: In this study, one third of patients seen were offered testing and the HIV testing rate was fivefold higher than that of previously observed in this service. Most patients accepted testing when offered. As HIV-positive status impacts on the medical management of cancer patients, we recommend that HIV screening should be performed in settings, where HIV prevalence is >0.1%. Phase II of the IBITOP study is now underway to explore barriers to HIV screening among oncologists and patients following the updated national HIV testing guidelines which recommend testing in non-ADC patients undergoing chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Bacteria form biofilms on the surface of orthopaedic devices, causing persistent infections. Monitoring biofilm formation on bone grafts and bone substitutes is challenging due to heterogeneous surface characteristics. We analyzed various bone grafts and bone substitutes regarding their propensity for in-vitro biofilm formation caused by S. aureus and S. epidermidis. Methods: Beta-tricalciumphosphate (b-TCP, ChronOsTM), processed human spongiosa (TutoplastTM) and PMMA (PalacosTM) were investigated. PE was added as a growth control. As test strains S. aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) were used. Test materials were incubated with 105 cfu/ml. After 24 h, test materials were removed and washed, followed by a standardised sonication protocol. The resulting sonication fluid was plated and bacterial counts were enumerated and expressed as cfu/sample. Sonicated samples were transferred to a microcalorimeter (TA Instrument) and heat flow monitored over a 24 h period with a precision of 0.0001°C and a sensitiviy of 200 μW. Experiments were performed in triplicates to calculate the mean ± SD. One-way ANOVA analysis was used for statistical analysis. Results: Bacterial counts (log10 cfu/sample) were highest on b-TCP (S. aureus 7.67 ± 0.17; S. epidermidis 8.14 ± 0.05) while bacterial density (log10 cfu/surface) was highest on PMMA (S. aureus 6.12 ± 0.2, S. epidermidis 7.65 ± 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (b-TCP and Tutoplast, p <0.001) compared to the smooth materials (PMMA and PE) with no differences between b-TCP and TutoplastTM (p >0.05) or PMMA and PE (p >0.05). In contrast, for S. epidermidis biofilms the detection time was different (p <0.001) between all materials except between Tutoplast and PE (p >0.05). Conclusion: Our results demonstrate biofilm formation with both strains on all tested materials. Microcalorimetry was able to detect quantitatively the amount of biofilm. Further studies are needed to see whether calorimetry is a suitable tool also to monitor approaches to prevent and treat infections associated with bone grafts and bone substitutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniature diffusion size classifiers (miniDiSC) are novel handheld devices to measure ultrafine particles (UFP). UFP have been linked to the development of cardiovascular and pulmonary diseases; thus, detection and quantification of these particles are important for evaluating their potential health hazards. As part of the UFP exposure assessments of highwaymaintenance workers in western Switzerland, we compared a miniDiSC with a portable condensation particle counter (P-TRAK). In addition, we performed stationary measurements with a miniDiSC and a scanning mobility particle sizer (SMPS) at a site immediately adjacent to a highway. Measurements with miniDiSC and P-TRAK correlated well (correlation of r = 0.84) but average particle numbers of the miniDiSC were 30%âeuro"60% higher. This difference was significantly increased for mean particle diameters below 40 nm. The correlation between theminiDiSC and the SMPSduring stationary measurements was very high (r = 0.98) although particle numbers from the miniDiSC were 30% lower. Differences between the three devices were attributed to the different cutoff diameters for detection. Correction for this size dependent effect led to very similar results across all counters.We did not observe any significant influence of other particle characteristics. Our results suggest that the miniDiSC provides accurate particle number concentrations and geometric mean diameters at traffic-influenced sites, making it a useful tool for personal exposure assessment in such settings.

Relevância:

20.00% 20.00%

Publicador: