171 resultados para valve flat organizzazione videogiochi computer distribuzione digitale steam


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stents have a long history in traditional valve surgery as both, porcine biological valves as well as pericardial valves are mounted on stents prior to implantation. Recently stent-mounted biological devices have been compressed up to the point, where they can be passed through a catheter. Various routes can be distinguished for implantation: open access, the trans-vascular route in antegrade or retrograde fashion, as well as direct trans-apical or trans-atrial access. Direct access has the potentialforvideo-endoscopic valve replacement. In theory, as well as in the experimental setting, valved stents have been implanted in tricuspid and caval position respectively, as well as in pulmonary, mitral and aortic locations. The largest clinical experience has been achieved in pulmonary position whereas current efforts target the aortic position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sophisticated magnetic resonance tagging techniques provide powerful tools for the non-invasive assessment of the local heartwall motion towards a deeper fundamental understanding of local heart function. For the extraction of motion data from the time series of magnetic resonance tagged images and for the visualization of the local heartwall motion a new image analysis procedure has been developed. New parameters have been derived which allows quantification of the motion patterns and are highly sensitive to any changes in these patterns. The new procedure has been applied for heart motion analysis in healthy volunteers and in patient collectives with different heart diseases. The achieved results are summarized and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Clinical practice does not always reflect best practice and evidence, partly because of unconscious acts of omission, information overload, or inaccessible information. Reminders may help clinicians overcome these problems by prompting the doctor to recall information that they already know or would be expected to know and by providing information or guidance in a more accessible and relevant format, at a particularly appropriate time. OBJECTIVES: To evaluate the effects of reminders automatically generated through a computerized system and delivered on paper to healthcare professionals on processes of care (related to healthcare professionals' practice) and outcomes of care (related to patients' health condition). SEARCH METHODS: For this update the EPOC Trials Search Co-ordinator searched the following databases between June 11-19, 2012: The Cochrane Central Register of Controlled Trials (CENTRAL) and Cochrane Library (Economics, Methods, and Health Technology Assessment sections), Issue 6, 2012; MEDLINE, OVID (1946- ), Daily Update, and In-process; EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ); EPOC Specialised Register, Reference Manager, and INSPEC, Engineering Village. The authors reviewed reference lists of related reviews and studies.  SELECTION CRITERIA: We included individual or cluster-randomized controlled trials (RCTs) and non-randomized controlled trials (NRCTs) that evaluated the impact of computer-generated reminders delivered on paper to healthcare professionals on processes and/or outcomes of care. DATA COLLECTION AND ANALYSIS: Review authors working in pairs independently screened studies for eligibility and abstracted data. We contacted authors to obtain important missing information for studies that were published within the last 10 years. For each study, we extracted the primary outcome when it was defined or calculated the median effect size across all reported outcomes. We then calculated the median absolute improvement and interquartile range (IQR) in process adherence across included studies using the primary outcome or median outcome as representative outcome. MAIN RESULTS: In the 32 included studies, computer-generated reminders delivered on paper to healthcare professionals achieved moderate improvement in professional practices, with a median improvement of processes of care of 7.0% (IQR: 3.9% to 16.4%). Implementing reminders alone improved care by 11.2% (IQR 6.5% to 19.6%) compared with usual care, while implementing reminders in addition to another intervention improved care by 4.0% only (IQR 3.0% to 6.0%) compared with the other intervention. The quality of evidence for these comparisons was rated as moderate according to the GRADE approach. Two reminder features were associated with larger effect sizes: providing space on the reminder for provider to enter a response (median 13.7% versus 4.3% for no response, P value = 0.01) and providing an explanation of the content or advice on the reminder (median 12.0% versus 4.2% for no explanation, P value = 0.02). Median improvement in processes of care also differed according to the behaviour the reminder targeted: for instance, reminders to vaccinate improved processes of care by 13.1% (IQR 12.2% to 20.7%) compared with other targeted behaviours. In the only study that had sufficient power to detect a clinically significant effect on outcomes of care, reminders were not associated with significant improvements. AUTHORS' CONCLUSIONS: There is moderate quality evidence that computer-generated reminders delivered on paper to healthcare professionals achieve moderate improvement in process of care. Two characteristics emerged as significant predictors of improvement: providing space on the reminder for a response from the clinician and providing an explanation of the reminder's content or advice. The heterogeneity of the reminder interventions included in this review also suggests that reminders can improve care in various settings under various conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 56-year-old patient admitted to hospital for the suspicion of an acute coronary syndrome underwent coronary angiography without detection of significant lesions. Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung volume reduction with valves is increasingly used to treat selected patients with severe emphysema. The indications for this procedure have been previously described; however, its contraindications have not yet been conclusively established. This case highlights the potentially severe complications of endobronchial one-way valve placement in the setting of a previous pleurodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ocular toxoplasmosis is the principal cause of posterior uveitis and a leading cause of blindness. Animal models are required to improve our understanding of the pathogenesis of this disease. The method currently used for the detection of retinal cysts in animals involves the observation, under a microscope, of all the sections from infected eyes. However, this method is time-consuming and lacks sensitivity. We have developed a rapid, sensitive method for observing retinal cysts in mice infected with Toxoplasma gondii. This method involves combining the flat-mounting of retina - a compromise between macroscopic observation and global analysis of this tissue - and the use of an avirulent recombinant strain of T. gondii expressing the Escherichia coli beta-galactosidase gene, visually detectable at the submacroscopic level. Single cyst unilateral infection was found in six out of 17 mice killed within 28 days of infection, whereas a bilateral infection was found in only one mouse. There was no correlation between brain cysts number and ocular infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected animals were followed for 3 d. ClfA-positive lactococci successfully colonized damaged valves, but were spontaneously eradicated over 48 h. In contrast, FnBPA-positive lactococci progressively increased bacterial titers in vegetations and spleens. At imaging, ClfA-positive lactococci were restricted to the vegetations, whereas FnBPA-positive lactococci also invaded the adjacent endothelium. This reflected the capacity of FnBPA to trigger cell internalization in vitro. Because FnBPA carries both fibrinogen- and fibronectin-binding domains, we tested the role of these functionalities by deleting the fibrinogen-binding domain of FnBPA and supplementing it with the fibrinogen-binding domain of ClfA in cis or in trans. Deletion of the fibrinogen-binding domain of FnBPA did not alter fibronectin binding and cell internalization in vitro. However, it totally abrogated valve infectivity in vivo. This ability was restored in cis by inserting the fibrinogen-binding domain of ClfA into truncated FnBPA, and in trans by coexpressing full-length ClfA and truncated FnBPA on two separate plasmids. Thus, fibrinogen and fibronectin binding could cooperate for S. aureus valve colonization and endothelial invasion in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stable carbon and oxygen isotope compositions of fossil ostracods are powerful tools to estimate past environmental and climatic conditions. The basis for such interpretations is that the calcite of the valves reflects the isotopic composition of water and its temperature of formation. However, calcite of ostracods is known not to form in isotopic equilibrium with water and different species may have different offsets from inorganic precipitates of calcite formed under the same conditions. To estimate the fractionation during ostracod valve calcification, the oxygen and carbon isotope compositions of 15 species living in Lake Geneva were related to their autoecology and the environmental parameters measured during their growth. The results indicate that: (1) Oxygen isotope fractionation is similar for all species of Candoninae with an enrichment in 18O of more than 30/00 relative to equilibrium values for inorganic calcite. Oxygen isotope fractionation for Cytheroidea is less discriminative relative to the heavy oxygen, with enrichments in 18O for these species of 1.7 to 2.30/00. Oxygen isotope fractionations for Cyprididae are in-between those of Candoninae and Cytheroidea. The difference in oxygen isotope fractionation between ostracods and inorganic calcite has been interpreted as resulting from a vital effect. (2) Comparison with previous work suggests that oxygen isotope fractionation may depend on the total and relative ion content of water. (3) Carbon isotope compositions of ostracod valves are generally in equilibrium with DIC. The specimens' δ13C values are mainly controlled by seasonal variations in δ13CDIC of bottom water or variation thereof in sediment pore water. (4) Incomplete valve calcification has an effect on carbon and oxygen isotope compositions of ostracod valves. Preferential incorporation of at the beginning of valve calcification may explain this effect. (5) Results presented here as well as results from synthetic carbonate growth indicate that different growth rates or low pH within the calcification site cannot be the cause of oxygen isotope 'vital effects' in ostracods. Two mechanisms that might enrich the 18O of ostracod valves are deprotonation of that may also contribute to valve calcification, and effects comparable to salt effects with high concentrations of Ca and/or Mg within the calcification site that may also cause a higher temperature dependency of oxygen isotope fractionation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Therapeutic drug monitoring (TDM) aims at optimizing treatment by individualizing dosage regimen based on measurement of blood concentrations. Maintaining concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculation represents a gold standard in TDM approach but requires computing assistance. In the last decades computer programs have been developed to assist clinicians in this assignment. The aim of this benchmarking was to assess and compare computer tools designed to support TDM clinical activities.¦Method: Literature and Internet search was performed to identify software. All programs were tested on common personal computer. Each program was scored against a standardized grid covering pharmacokinetic relevance, user-friendliness, computing aspects, interfacing, and storage. A weighting factor was applied to each criterion of the grid to consider its relative importance. To assess the robustness of the software, six representative clinical vignettes were also processed through all of them.¦Results: 12 software tools were identified, tested and ranked. It represents a comprehensive review of the available software's characteristics. Numbers of drugs handled vary widely and 8 programs offer the ability to the user to add its own drug model. 10 computer programs are able to compute Bayesian dosage adaptation based on a blood concentration (a posteriori adjustment) while 9 are also able to suggest a priori dosage regimen (prior to any blood concentration measurement), based on individual patient covariates, such as age, gender, weight. Among those applying Bayesian analysis, one uses the non-parametric approach. The top 2 software emerging from this benchmark are MwPharm and TCIWorks. Other programs evaluated have also a good potential but are less sophisticated (e.g. in terms of storage or report generation) or less user-friendly.¦Conclusion: Whereas 2 integrated programs are at the top of the ranked listed, such complex tools would possibly not fit all institutions, and each software tool must be regarded with respect to individual needs of hospitals or clinicians. Interest in computing tool to support therapeutic monitoring is still growing. Although developers put efforts into it the last years, there is still room for improvement, especially in terms of institutional information system interfacing, user-friendliness, capacity of data storage and report generation.