104 resultados para pharmaceutical samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The population of elderly persons is increasing andnegative outcomes due to polymedication are frequent. Discrepanciesin information about medication are frequent when older persons aretransitioning from hospital to home, increasing the risk of hospitalreadmission. The aims of this study were a) to determine discrepanciesin medical regimen indicated in two official discharge documents(DS = discharge summary, DP=discharge prescription); b) to characterizethe pharmacotherapy prescribed in older patients dischargedfrom a geriatric service.Materials & Methods Elderly patients (N=230) discharged from thegeriatric service (CHUV, Lausanne) over a 6-month period (January toJune 2009) were selected. Community pharmacists compared DS andDP to identify discrepancies including (a) drugs' name; (b) schedule ofadministration, dosage, frequency, prn prescription, treatment durationand galenic formulation. Beers' criteria were applied to identifypotentially inappropriate drugs and a descriptive analysis of drug costs,prescription profiles and generics were also performed.Results On average, patients were 82 ± 7 years old and stayed23.0 ± 11.6 days in the geriatric service. The delay between the datesof patient's discharge with the DP and the sending of the DS to hisgeneral physician averaged 14.0 ± 7.5 days (range 1-55). The DPhad an average of 10.0 ± 3.3 drugs (range 2-19). 77% of patients hadat least one discrepancy. A drug was missing on the DS in 57.8% ofpatients and 19.6% had a missing prn prescription. Among the 2312drugs prescribed, 3% belonged to Beers' list. They were prescribed to61 patients (26.5%), with 6 patients cumulating two Beers' potentiallyinappropriate drugs in their treatment. Analgesics (85% of thepatients), anticoagulants (80%), mineral supplements (77%), laxatives(52%) and antihypertensives (46%) were the drug classes most frequentlyprescribed. Mean costs of treatment as per DP was160.4 ± 179.4 Euros. Generic prescription represented more than 5%of the costs for 3 therapeutic classes (cholesterol-lowering agents(64%), antihypertensives (50%) and antidepressants (47%)).Discussion & Conclusion The high discrepancy rate between medicationlisted in the DP and the DS highlights a need for safetyimprovement. Potential benefits are expected from reinforced pharmacist-physician collaboration in transition from hospital to primarycare. In addition, even though Beers' criteria are questionable, thedrugs prescribed in this already fragile population, and the potentialopportunities of economical optimizations, are advocating thedevelopment and the scientific evaluation of a structured advancedcollaborative pharmacy practice service. This foresees improvedeffectiveness, safety and efficiency in the medication management ofelderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the transit pulse method, we have determined compressional wave velocities of rocks from various geological units belonging to the Penninic zone along the NFP20-West profiles of the Swiss western Alps. The velocities have been measured at confining pressures up to 400 MPa, along three orthogonal axes defined by the macrostructure of the rocks. The samples analysed show a degree of metamorphism ranging from greenschist to eclogite facies. This collection includes schists, dolomites, gneisses and ophiolitic rocks. The mean velocities range from 5.9 km/s for a quartzitic calcschist to 7.9 km/s for an eclogitic metagabbro. The velocity anisotropy is as high as 20 %. The range of acoustic impedance is wide, from 15 to 27 10(6) kg/m2s. From these measurements, normal incident reflection coefficients for likely rock assemblages within and between geological units were estimated in order to interpret zone of the strong reflections recorded along the seismic profiles. Reflection coefficients as high as 0.17 could be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The epithelial sodium channel (ENaC) is composed of three homologous subunits: alpha, beta, and gamma. Mutations in the Scnn1b and Scnn1g genes, which encode the beta and the gamma subunits of ENaC, cause a severe form of hypertension (Liddle syndrome). The contribution of genetic variants within the Scnn1a gene, which codes for the alpha subunit, has not been investigated. METHODS: We screened for mutations in the COOH termini of the alpha and beta subunits of ENaC. Blood from 184 individuals from 31 families participating in a study on the genetics of hypertension were analyzed. Exons 13 of Scnn1a and Scnn1b, which encode the second transmembrane segment and the COOH termini of alpha- and beta-ENaC, respectively, were amplified from pooled DNA samples of members of each family by PCR. Constant denaturant capillary electrophoresis (CDCE) was used to detect mutations in PCR products of the pooled DNA samples. RESULTS: The detection limit of CDCE for ENaC variants was 1%, indicating that all members of any family or up to 100 individuals can be analyzed in one CDCE run. CDCE profiles of the COOH terminus of alpha-ENaC in pooled family members showed that the 31 families belonged to four groups and identified families with genetic variants. Using this approach, we analyzed 31 rather than 184 samples. Individual CDCE analysis of members from families with different pooled CDCE profiles revealed five genotypes containing 1853G-->T and 1987A-->G polymorphisms. The presence of the mutations was confirmed by DNA sequencing. For the COOH terminus of beta-ENaC, only one family showed a different CDCE profile. Two members of this family (n = 5) were heterozygous at 1781C-->T (T594M). CONCLUSION: CDCE rapidly detects point mutations in these candidate disease genes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the low sensitivity of amoebal coculture, we developed a specific real-time PCR for the detection of Parachlamydia. The analytical sensitivity was high, and the inter- and intrarun variabilities were low. When the PCR was applied to nasopharyngeal aspirates, it was positive for six patients with bronchiolitis. Future studies should assess the role of Parachlamydia in bronchiolitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PRINCIPLES: The literature has described opinion leaders not only as marketing tools of the pharmaceutical industry, but also as educators promoting good clinical practice. This qualitative study addresses the distinction between the opinion-leader-as-marketing-tool and the opinion-leader-as-educator, as it is revealed in the discourses of physicians and experts, focusing on the prescription of antidepressants. We explore the relational dynamic between physicians, opinion leaders and the pharmaceutical industry in an area of French-speaking Switzerland. METHODS: Qualitative content analysis of 24 semistructured interviews with physicians and local experts in psychopharmacology, complemented by direct observation of educational events led by the experts, which were all sponsored by various pharmaceutical companies. RESULTS: Both physicians and experts were critical of the pharmaceutical industry and its use of opinion leaders. Local experts, in contrast, were perceived by the physicians as critical of the industry and, therefore, as a legitimate source of information. Local experts did not consider themselves opinion leaders and argued that they remained intellectually independent from the industry. Field observations confirmed that local experts criticised the industry at continuing medical education events. CONCLUSIONS: Local experts were vocal critics of the industry, which nevertheless sponsor their continuing education. This critical attitude enhanced their credibility in the eyes of the prescribing physicians. We discuss how the experts, despite their critical attitude, might still be beneficial to the industry's interests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to imbalance in genetic material contribution, gynecological samples collected following a sexual assault are challenging to process in order to resolve the male contributor's DNA profile. We set up a new and fast procedure for the recovery and separation of cells from cotton swabs, or other supports. Using spermatozoa specific CD52 antibody coupled to magnetic beads along with magnetic columns, this procedure was first developed and optimized by flow cytometry. It allows the recovery of two enriched cell fractions: a sperm fraction, mostly enriched with the alleged offender's spermatozoa, and a non-sperm fraction, mostly enriched with cells from the victim. Processing fresh as well as six months old mock samples, made of buccal swabs loaded with sperm dilutions, resulted in full single NGM SElect DNA profiles of the sperm donors, respectively the epithelial cells donors, for the sperm and the non-sperm fractions. Untreated duplicate samples processed in parallel only provided the autosomal DNA profiles of the epithelial cells donors. This new procedure can be rapidly tested and adopted by forensic laboratories worldwide as it uses material already commercially available. Moreover it can be easily automated with existing platform, and could therefore provide a mean to rapidly reduce existing backlogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Candida albicans adaptation to the host requires a profound reprogramming of the fungal transcriptome as compared to in vitro laboratory conditions. A detailed knowledge of the C. albicans transcriptome during the infection process is necessary in order to understand which of the fungal genes are important for host adaptation. Such genes could be thought of as potential targets for antifungal therapy. The acquisition of the C. albicans transcriptome is, however, technically challenging due to the low proportion of fungal RNA in host tissues. Two emerging technologies were used recently to circumvent this problem. One consists of the detection of low abundance fungal RNA using capture and reporter gene probes which is followed by emission and quantification of resulting fluorescent signals (nanoString). The other is based first on the capture of fungal RNA by short biotinylated oligonucleotide baits covering the C. albicans ORFome permitting fungal RNA purification. Next, the enriched fungal RNA is amplified and subjected to RNA sequencing (RNA-seq). Here we detail these two transcriptome approaches and discuss their advantages and limitations and future perspectives in microbial transcriptomics from host material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since routine eubacterial 16S rRNA PCR does not amplify members of the Chlamydiales order, we tested all samples received in our laboratory during a 10 months period using a pan-Chlamydiales real-time PCR. 3 of 107 samples (2.8%) revealed to be positive, suggesting a role of some Chlamydiales in the pathogenesis of chronic bronchial stenosis or bronchial stenosis superinfection and as agents of orthopaedic prosthesis infections.