186 resultados para MICRODISK INJECTION-LASER
Resumo:
Abstract Purpose: XG-102, a TAT-coupled dextrogyre peptide inhibiting the c-Jun N-terminal kinase, was shown efficient in the treatment of experimental uveitis. Preclinical studies are now performed to determine optimal XG-102 dose and route of administration in endotoxin-induced uveitis (EIU) in rats with the purpose of clinical study design. METHODS: EIU was induced in Lewis rats by lipopolysaccharides (LPS) injection. XG-102 was administered at the time of LPS challenge by intravenous (IV; 3.2, 35 or 355 μg/injection), intravitreal (IVT; 0.08, 0.2 or 2.2 μg/eye), or subconjunctival (SCJ; 0.2, 1.8 or 22 μg/eye) routes. Controls received either the vehicle (saline) or dexamethasone phosphate injections. Efficacy was assessed by clinical scoring, infiltrating cells count, and expression of inflammatory mediators [inducible nitric oxide synthase (iNOS), cytokine-induced neutrophil chemoattractant-1 (CINC-1)]. The effect of XG-102 on phosphorylation of c-Jun was evaluated by Western blot. RESULTS: XG-102 demonstrated a dose-dependent anti-inflammatory effect in EIU after IV and SCJ administrations. Respective doses of 35 and 1.8 μg were efficient as compared with the vehicle-injected controls, but only the highest doses, respectively 355 and 22 μg, were as efficient as dexamethasone phosphate. After IVT injections, the anti-inflammatory effect of XG-102 was clinically evaluated similar to the corticoid's effect with all the tested doses. Regardless of the administration route, the lowest efficient doses of XG-102 significantly decreased the ration of phospho c-Jun/total c-Jun, reduced cells infiltration in the treated eyes, and significantly downregulated iNOS and CINC-1 expression in the retina. CONCLUSION: These results confirm that XG-102 peptide has potential for treating intraocular inflammation. SCJ injection appears as a good compromise to provide a therapeutic effect while limiting side effects.
Resumo:
Risperidone is metabolized by polymorphic enzymes, and a large variability in plasma concentration and therapeutic response is observed. Risperidone long-acting injection (RLAI) avoids the first-pass effect, and little is known about the influence of gene polymorphisms involved in its pharmacokinetics. The influence on plasma concentrations of risperidone (RIS), its metabolite 9-hydroxy-risperidone, and on adverse effects were investigated for polymorphisms of cytochrome P450 2D6 (CYP2D6) (*3, *4, *5, *6), CYP3A (CYP3A4*1B, CYP3A4 rs4646437, CYP3A5*3, CYP3A7*1C), ABCB1 (1236C>T, 2677G>T, 3435C>T), NR1/2 coding for pregnane X receptor (rs1523130, rs2472677, rs7643645), and for CYP3A activity measured by a phenotyping test. Forty-two patients with at least 4 consecutive unchanged doses of RLAI were included in a multicenter cross-sectional study. A 55% lower dose-adjusted plasma levels of RIS were observed for CYP2D6 ultrarapid metabolizers (n = 5) as compared with CYP2D6 intermediate metabolizers (P < 0.007). NR1/2 polymorphism (rs7643645A>G) influenced RIS exposure with a 2.8-fold lower active moiety (P = 0.031) in GG compared with the AA genotype. This was confirmed in a second independent cohort (n = 16). Furthermore, high-density lipoprotein cholesterol was positively correlated with CYP3A activity (P = 0.01), and the NR1/2 (rs2472677) polymorphism was associated with different adverse effects including prolactin plasma levels adjusted for age and sex. In conclusion, our results confirmed the influence of CYP2D6 genotype on plasma levels of RIS. This is the first report on the influence of NR1/2 polymorphisms on RLAI exposure and on drug-induced adverse effects. These results should be validated in larger cohorts.
Resumo:
INTRODUCTION: Functional muscle recovery after peripheral nerve injury is far from optimal, partly due to atrophy of the muscle arising from prolonged denervation. We hypothesized that injecting regenerative cells into denervated muscle would reduce this atrophy. METHODS: A rat sciatic nerve lesion was performed, and Schwann cells or adipose-derived stem cells, untreated or induced to a "Schwann-cell-like" phenotype (dASC), were injected into the gastrocnemius muscle. Nerves were either repaired immediately or capped to prevent muscle reinnervation. One month later, functionality was measured using a walking track test, and muscle atrophy was assessed by examining muscle weight and histology. RESULTS: Schwann cells and dASC groups showed significantly better scores on functional tests when compared with injections of growth medium alone. Muscle weight and histology were also significantly improved in these groups. CONCLUSION: Cell injections may reduce muscle atrophy and could benefit nerve injury patients.
Resumo:
Normal rats were injected intravenously with 131I- and 125I-labeled intact murine and chimeric mouse-human monoclonal antibodies directed against carcinoembryonic antigen or with the corresponding F(ab')2 fragments. At different times after injection, individual animals were killed and radioactivity of blood and major organs, including bones and bone marrow, was determined. Ratios comparing radioactivity concentration in different tissues with that of bone marrow were calculated and found to remain stable during several effective half-lives of the antibodies. Mean bone marrow radioactivity was 35% (range, 29%-40%) of that of blood and 126% (range, 108%-147%) of that of liver after injection of intact Mabs or F(ab')2 fragments. In nude rats bearing human colon carcinoma xenografts producing carcinoembryonic antigen, relative bone marrow radioactivity was slightly lower than that in normal rats.
Resumo:
BACKGROUND: The objectives of the present study were to evaluate Aids prevention in drug users attending low threshold centres providing sterile injection equipment in Switzerland, to identify the characteristics of these users, and to monitor the progress of indicators of drug-related harm. METHODS: This paper presents results from a cross-sectional survey carried out in 1994. RESULTS: The mean age of attenders was 28 years, and women represented 27% of the sample. 75% of attenders used a combination of hard drugs (heroin and cocaine). Mean duration of heroin consumption was 8 years, and of cocaine 7 years; 76% of attenders had a fixed abode, but only 34% had stable employment; 45% were being treated with methadone; 9% had shared their injection material in the last 6 months; 24% always used condoms in the case of a stable relationship, and 71% in casual relationships. In a cluster analysis constructed on the basis of multiple correspondence analysis, two distinct profiles of users emerge: highly marginalised users with a high level of consumption (21%); irregular users, better integrated socially, of which the majority are under methadone treatment (79%). CONCLUSION: Theses centres play a major role in Aids prevention. Nevertheless, efforts to improve the hygiene conditions of drug injection in Switzerland should be pursued and extended. At the same time, prevention of HIV sexual transmissions should be reinforced.
Resumo:
A statistical methodology for the objective comparison of LDI-MS mass spectra of blue gel pen inks was evaluated. Thirty-three blue gel pen inks previously studied by RAMAN were analyzed directly on the paper using both positive and negative mode. The obtained mass spectra were first compared using relative areas of selected peaks using the Pearson correlation coefficient and the Euclidean distance. Intra-variability among results from one ink and inter-variability between results from different inks were compared in order to choose a differentiation threshold minimizing the rate of false negative (i.e. avoiding false differentiation of the inks). This yielded a discriminating power of up to 77% for analysis made in the negative mode. The whole mass spectra were then compared using the same methodology, allowing for a better DP in the negative mode of 92% using the Pearson correlation on standardized data. The positive mode results generally yielded a lower differential power (DP) than the negative mode due to a higher intra-variability compared to the inter-variability in the mass spectra of the ink samples.
Resumo:
The effect of a synthetic atrial natriuretic peptide (h-ANP, 25 amino acids, Wy-47.663) on blood pressure, renal electrolyte excretion, plasma catecholamines, and plasma renin activity was studied in nine patients with cirrhosis of the liver and ascites. The peptide was infused intravenously at 24-h intervals for 2 h in groups of four patients each in two different doses (0.015 and 0.075 micrograms/kg/min or 0.06 and 0.3 micrograms/kg/min). A control experiment with the vehicle was performed in all patients. In three patients h-ANP (1 and 2 micrograms/kg i.v.) was administered as an intravenous bolus injection. Consistent falls in blood pressure were observed during h-ANP infusion only with the two higher doses. The two lower infused doses induced a consistent natriuresis; this renal response was abolished when the two larger doses were used. When given as a bolus, h-ANP had a natriuretic effect comparable to that of the two lower doses of infused h-ANP. Plasma catecholamines and plasma renin activity increased during infusion of the two higher doses of h-ANP. It thus appears that in patients with cirrhosis and ascites, the natriuretic effect of infused h-ANP decreases rather than increases when the doses are raised. Bolus administration of h-ANP may be less prone to trigger counterbalancing responses and side-effects.
Resumo:
Purpose: To investigate the differences between Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: 105 eyes of 56 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter/500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter/695nm barrier filter) before and after FFA. The quality of the FAF images was compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo-and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior resolution in 18, while Topcon images were estimated superior in 29 eyes. No difference was found in 58 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found associated with better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (72%), but showed mild autofluorescence on Topcon (85%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 53% Iso-FAF, in 43% mild Hypo-FAF, and in 4% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to serous exudation showed better on HRA. Cystic edema was visible only on HRA in a petaloid hyper-FAF pattern in 83%, while only two eyes (17%) showed similar behavior in both HRA- and Topcon images. Hard exudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blockage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract and poor fixation respectively. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behavior, there are differences between the 2 systems which need to be taken into account when interpreting the images.
Resumo:
Background. Early identification of pathogens from blood cultures using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry may optimize the choice of empirical antibiotic therapy in the setting of bloodstream infections. We aimed to assess the impact of this new technology on the use of antibiotic treatment in patients with gram-negative bacteremia. Methods. We conducted a prospective observational study from January to December 2010 to evaluate the sequential and separate impacts of Gram stain reporting and MALDI-TOF bacterial identification performed on blood culture pellets in patients with gram-negative bacteremia. The primary outcome was the impact of MALDI-TOF on empirical antibiotic choice. Results. Among 202 episodes of gram-negative bacteremia, Gram stain reporting had an impact in 42 cases (20.8%). MALDI-TOF identification led to a modification of empirical therapy in 71 of all 202 cases (35.1%), and in 16 of 27 cases (59.3%) of monomicrobial bacteremia caused by AmpC-producing Enterobacteriaceae. The most frequently observed impact was an early appropriate broadening of the antibiotic spectrum in 31 of 71 cases (43.7%). In total, 143 of 165 episodes (86.7%) of monomicrobial bacteremia were correctly identified at genus level by MALDI-TOF. Conclusions. In a low prevalence area for extended spectrum betalactamases (ESBL) and multiresistant gram-negative bacteria, MALDI-TOF performed on blood culture pellets had an impact on the clinical management of 35.1% of all gram-negative bacteremia cases, demonstrating a greater impact than Gram stain reporting. Thus, MALDI-TOF could become a vital second step beside Gram stain in guiding the empirical treatment of patients with bloodstream infection.
Resumo:
Abstract Purpose: We aimed to investigate the safety, tolerability, and systemic diffusion of a single escalating dose of XG-102 (a 31-D-amino-acid peptide inhibiting JNK pathway activation), administered subconjunctivally in the treatment of post-surgery or post-trauma intraocular inflammation. Methods: This is a dose-escalating, tolerance Phase Ib study. Twenty patients with post-surgery or post-traumatic intraocular inflammation were assigned to 1 of the 4 dose escalating (45, 90, 450, or 900 μg XG-102) groups of 5 patients each. Patients were evaluated at 24, 48 h, 8, and 28 days following the administration of XG-102, including laboratory tests, standard eye examinations, vital signs, and occurrence of adverse events. A single plasma quantification of XG-102 was performed 30 min after administration, according to previous pharmacokinetics studies performed on volunteers. Results: A total of 17 non-serious adverse events, considered unrelated to the study treatment, were reported for 10 patients. The adverse event incidence was not related to the drug dose. All patients experienced a decrease in intraocular inflammation as of 24 h post-administration and this decrease was sustained up to 28 days thereafter. No patient required local injection or systemic administration of corticoids following the administration of XG-102. XG-102 was undetectable in the first 3 dose groups. In the fourth-dose group (900 μg) the XG-102 plasma levels were above the limit of detection for 3 patients and above the limit of quantification for 1 patient. Conclusions: In this first clinical trial using XG-102, administered as a single subconjunctival injection as adjunct therapy, in patients with recent post-surgery or post-trauma intraocular inflammation is safe and well tolerated. Further studies are required to evaluate its efficacy.
Resumo:
Neonatal treatment of A/J mice with DNP-Ficoll reduced or eliminated indirect anti-DNP PFC normally produced in response to adult challenge with DNP-keyhole limpet hemocyanin. The remaining direct anti-DNP PFC response was of low avidity. Spleen cells from neonatal A/J mice inhibited the in vitro but not the in vivo response of adult spleen cells to DNP-Ficoll.
Resumo:
Silver has been demonstrated to be a powerful cationization agent in mass spectrometry (MS) for various olefinic species such as cholesterol and fatty acids. This work explores the utility of metallic silver sputtering on tissue sections for high resolution imaging mass spectrometry (IMS) of olefins by laser desorption ionization (LDI). For this purpose, sputtered silver coating thickness was optimized on an assorted selection of mouse and rat tissues including brain, kidney, liver, and testis. For mouse brain tissue section, the thickness was adjusted to 23 ± 2 nm of silver to prevent ion suppression effects associated with a higher cholesterol and lipid content. On all other tissues, a thickness of at 16 ± 2 nm provided the best desorption/ionization efficiency. Characterization of the species by MS/MS showed a wide variety of olefinic compounds allowing the IMS of different lipid classes including cholesterol, arachidonic acid, docosahexaenoic acid, and triacylglyceride 52:3. A range of spatial resolutions for IMS were investigated from 150 μm down to the high resolution cellular range at 5 μm. The applicability of direct on-tissue silver sputtering to LDI-IMS of cholesterol and other olefinic compounds presents a novel approach to improve the amount of information that can be obtained from tissue sections. This IMS strategy is thus of interest for providing new biological insights on the role of cholesterol and other olefins in physiological pathways or disease.
Resumo:
Purpose: Fluoroscopy-guided sacroiliac joint (SIJ) injections are technically difficult to perform because of the complex anatomy with helicoidal conformation of the joint. Our study describes the procedure of CT-guided SIJ injection, its feasibility and its rate of success. Methods and materials: Retrospective study included 46 consecutive patients. The procedure was performed by 3 MSK radiologists and consisted in a puncture with a posterior approach in the inferior articular part of SIJ, then in an injection of iodinated contrast agent (1ml) with CT control of SIJ space opacification and finally in an injection of slowacting corticosteroid. The SIJ approach was noticed as correct if there was an inferior articular puncture and if the needle was in the articular space, and as impossible if there was ankylosis or osteophytosis. The study was divided in two successive periods: period 1 (4 first months) and period 2 (12 last months). Results: SIJ opacification was successful in 57% (26/46). We observed a learning curve: opacification was succeeded in 66% (23/35) and there was incorrect approach in 9% (3/35) during period 2 versus respectively 27% (3/11) and 45% (5/11) during period 1. Causes of failure were incorrect approach in 40% (6/20 too low, 2/20 too high), impossible approach in 30% (6/20) and unexplained in 30% (6/20). Mean duration of procedure was about 28 minutes. No complication occurred. Conclusion: CT guided SIJ injection is safe and successful in 66% after a training period. The success depends on SIJ correct approach and also on anatomical lesions.