235 resultados para Satisfaction measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Different routes of postoperative analgesia may be used after cesarean section: systemic, spinal or epidural [1]. Although the efficacy of these alternative analgesic regimen has already been studied [2, 3], very few studies have compared patients' satisfaction between them. Methodology: After ethical committee acceptation, 100 ASA 1 patients scheduled for an elective cesarean section were randomized in 4 groups. After a standardized spinal anesthesia (hyperbaric bupivacaine 10 mg and fentanyl 20 μg), each group had a different postoperative analgesic regimen: - Group 1: oral paracetamol 4x1 g/24 h, oral ibuprofene 3x600 mg/24 h and subcutaneous morphine on need (0.1 mg/kg 6x/24 h) - Group 2: intrathecal morphine (100 μg) and then same as Group 1 - Group 3: oral paracetamol 4x1 g/24 h, oral ibuprofene 3x600 mg/24 h and PCEA with fentanyl 5 μg/ml epidural solution - Group 4: oral paracetamol 4x1g/24 h, oral ibuprofene 3x600 mg/ 24 h and PCEA with bupivacaine 0.1% and fentanyl 2 μg/ml epidural solution After 48 hours, a specific satisfaction questionnaire was given to all patients which permitted to obtain 2 different scores concerning postoperative analgesia: a global satisfaction score (0-10) and a detailed satisfaction score (5 questions scored 0-10 with a summative score of 0-50). Both scores, expressed as mean ± SD, were compared between the 4 groups with a Kruskall-Wallis test and between each group with a Mann-Whitney test. A P-value <0.05 was considered significant. Results: Satisfaction scores Gr. 1 (n = 25) Gr. 2 (n = 25) Gr. 3 (n = 25) Gr. 4 (n = 25) P-value global (0-10) 8.2 ± 1.2 9.0 ± 1.0 7.8 ± 2.1 6.5 ± 2.5 0.0006 detailed (0-50) 40 ± 6 43 ± 5 38 ± 6 34 ± 8 0.0002 Conclusion: Satisfaction scores were significantly better in patients who received a systemic postoperative analgesia only (Groups 1 and 2) compared to patients who received systemic and epidural postoperative analgesia (Groups 3 and 4). The best scores were achieved with the combination of intrathecal morphine and multimodal systemic analgesia (Group 2) which allowed early ambulation without significant pain. Patients treated with postoperative epidural analgesia with combined local anesthetics and opioids (Group 4) obtained the worse scores (more restrictive nursing with less mobility, frequent asymmetrical block with insufficient analgesia on one side and motor block on the other)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study assessed whether breast cancer (BC) patients express similar levels of needs for equivalent severity of symptoms, functioning difficulties, or degrees of satisfaction with care aspects. BC patients who did (or not) report needs in spite of similar difficulties were identified among their sociodemographic or clinical characteristics. PATIENTS AND METHODS: Three hundred and eighty-four (73% response rate) BC patients recruited in ambulatory or surgery hospital services completed the European Organisation for Research and Treatment of Cancer Quality of Life questionnaire (EORTC QLQ)-C30 quality of life [health-related quality of life (HRQOL)], the EORTC IN-PATSAT32 (in-patient) or OUT-PATSAT35 (out-patient) satisfaction with care, and the supportive care needs survey short form 34-item (SCNS-SF34) measures. RESULTS: HRQOL or satisfaction with care scale scores explained 41%, 45%, 40% and 22% of variance in, respectively, psychological, physical/daily living needs, information/health system, and care/support needs (P < 0.001). BC patients' education level, having children, hospital service attendance, and anxiety/depression levels significantly predicted differences in psychological needs relative to corresponding difficulties (adjusted R(2) = 0.11). Medical history and anxiety/depression levels significantly predicted differences in information/health system needs relative to degrees of satisfaction with doctors, nurses, or radiotherapy technicians and general satisfaction (adjusted R(2) = 0.12). Unmet needs were most prevalent in the psychological domains across hospital services. CONCLUSIONS: Assessment of needs, HRQOL, and satisfaction with care highlights the subgroups of BC patients requiring better supportive care targeting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Even though there is evidence that both patients and oncology clinicians are affected by the quality of communication and that communication skills can be effectively trained, so-called Communication Skills Trainings (CSTs) remain heterogeneously implemented. METHODS: A systematic evaluation of the level of satisfaction of oncologists with the Swiss CST before (2000-2005) and after (2006-2012) it became mandatory. RESULTS: Levels of satisfaction with the CST were high, and satisfaction of physicians participating on a voluntary or mandatory basis did not significantly differ for the majority of the items. CONCLUSIONS: The evaluation of physicians' satisfaction over the years and after introduction of mandatory training supports recommendations for generalized implementation of CST and mandatory training for medical oncologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'activation des mastocytes se produit dans plusieurs conditions pathologiques et est principalement observée chez des patients développant une réaction anaphylactique. Dans la pratique clinique, la mesure de l'histamine et de ses métabolites dans le plasma et dans l'urine du patient peut être effectuée et montre parfois des résultats aussi précis que la mesure de la beta-tryptase dans le sang lorsqu'il est nécessaire de confirmer une activation mastocytaire. En revanche, la mesure de la beta tryptase dans l'urine dans un but diagnostic n'a que rarement été effectuée sur des personnes vivantes et a montré des résultats contradictoires. Dans le domaine de la médecine légale, la mesure de la beta-tryptase dans un but diagnostic est effectuée dans le sérum postmortem obtenu à partir de sang prélevé au niveau fémoral. Cependant, le sang peut être partiellement ou complètement indisponible dans certains cas spécifiques, dans les autopsies de nourrissons ou de corps sévèrement mutilés par exemple. Un des buts de notre étude est d'évaluer la pertinence de la mesure de la beta-tryptase dans des échantillons biologiques alternatifs, à savoir dans l'urine, l'humeur vitrée et le liquide péricardique. Pour cela nous avons sélectionné 94 cas d'autopsies comprenant 6 cas de réaction anaphylactique suite à l'administration de produits de contraste radiologique, 10 cas d'hypothermie, 10 cas d'acidocétose diabétique, 10 cas de suicide par arme à feu, 18 cas de décès consécutif à une injection d'héroïne, 10 cas de décès traumatiques, 10 cas de mort subite avec peu ou pas d'athérosclérose coronarienne, 10 cas de décès avec une athérosclérose coronarienne sévère mais sans signe d'infarctus du myocarde et 10 cas de décès consécutif à un infarctus du myocarde avec une athérosclérose coronarienne sévère. Dans tous les cas de réaction anaphylactique suite à l'administration de produit de contraste radiologique, les concentrations de beta-tryptase, mesurées dans le sérum postmortem et dans le liquide péricardique, ont montré des valeurs plus élevées que le seuil clinique de référence (11 ng/l) et le seuil postmortem de référence (45 ng/l). La concentration de beta-tryptase mesurée dans l'urine et l'humeur vitrée a montré des valeurs inférieures au seuil clinique dans tous les cas de notre étude. La mesure de la concentration de beta tryptase dans le liquide péricardique semble donc une alternative valable à la mesure dans le sérum postmortem, lorsque le sang fémoral n'est pas disponible durant l'autopsie, afin de poser un diagnostic de réaction anaphylactique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between 1986 and 1997, 13 shoulders in adult patients who had severe polyarticular juvenile idiopathic arthritis were treated with primary arthroplasty. Eleven shoulders were evaluated retrospectively by an independent observer with a mean follow-up of 9 years. Patient evaluation included pain Visual Analogue Scale, range of motion, Disabilities of the Arm, Shoulder and Hand score, and Short-Form 36. Patients' pain decreased significantly after surgery (mean 6.7). Forward elevation improved on average by 41.1 degrees and external rotation by 39.1 degrees , without evidence of shoulder instability. Final Short-Form 36 scores and Disabilities of the Arm, Shoulder and Hand results (mean, 44.7) were poor, but all patients rated themselves satisfied with the procedure. Shoulder arthroplasty provided pain relief for end-stage shoulder involvement in adult juvenile idiopathic arthritis. Improvement in external rotation in this severely affected group appears to have a beneficial effect on functional outcome.