114 resultados para Optical detector readout concepts
Resumo:
The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.
Resumo:
This paper presents a method to reconstruct 3D surfaces of silicon wafers from 2D images of printed circuits taken with a scanning electron microscope. Our reconstruction method combines the physical model of the optical acquisition system with prior knowledge about the shapes of the patterns in the circuit; the result is a shape-from-shading technique with a shape prior. The reconstruction of the surface is formulated as an optimization problem with an objective functional that combines a data-fidelity term on the microscopic image with two prior terms on the surface. The data term models the acquisition system through the irradiance equation characteristic of the microscope; the first prior is a smoothness penalty on the reconstructed surface, and the second prior constrains the shape of the surface to agree with the expected shape of the pattern in the circuit. In order to account for the variability of the manufacturing process, this second prior includes a deformation field that allows a nonlinear elastic deformation between the expected pattern and the reconstructed surface. As a result, the minimization problem has two unknowns, and the reconstruction method provides two outputs: 1) a reconstructed surface and 2) a deformation field. The reconstructed surface is derived from the shading observed in the image and the prior knowledge about the pattern in the circuit, while the deformation field produces a mapping between the expected shape and the reconstructed surface that provides a measure of deviation between the circuit design models and the real manufacturing process.
Resumo:
Intraclass correlation (ICC) is an established tool to assess inter-rater reliability. In a seminal paper published in 1979, Shrout and Fleiss considered three statistical models for inter-rater reliability data with a balanced design. In their first two models, an infinite population of raters was considered, whereas in their third model, the raters in the sample were considered to be the whole population of raters. In the present paper, we show that the two distinct estimates of ICC developed for the first two models can both be applied to the third model and we discuss their different interpretations in this context.
Resumo:
The topic of cardiorespiratory interactions is of extreme importance to the practicing intensivist. It also has a reputation for being intellectually challenging, due in part to the enormous volume of relevant, at times contradictory literature. Another source of difficulty is the need to simultaneously consider the interrelated functioning of several organ systems (not necessarily limited to the heart and lung), in other words, to adopt a systemic (as opposed to analytic) point of view. We believe that the proper understanding of a few simple physiological concepts is of great help in organizing knowledge in this field. The first part of this review will be devoted to demonstrating this point. The second part, to be published in a coming issue of Intensive Care Medicine, will apply these concepts to clinical situations. We hope that this text will be of some use, especially to intensivists in training, to demystify a field that many find intimidating.
Resumo:
The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility.
Resumo:
Endocarditis pathogens colonize valves with pre-existing sterile vegetations or valves with minimal endothelial lesions. Inflamed endothelia produce cytokines, integrins, and tissue factor, which in turn attract fibronectin, monocytes, and platelets. Bacteria attaching to such structures further activate the cascade, becoming embedded and protected from host defenses. Staphylococcus aureus also actively invade the endothelium, causing apoptosis and endothelial damage. Knowledge of this interplay identifies host factors as potential therapeutic targets. Blocking infection by modulating host factors might be opportune because host factors are conserved. In contrast, interfering with bacterial virulence factors might be more complicated because they vary among different bacteria.
Resumo:
PURPOSE OF REVIEW: Oculopalatal tremor (OPT) is an acquired disorder resulting from the interruption of a specific brainstem circuitry, the dentato-rubro-olivary pathway or Guillain-Mollaret triangle. The recent literature on OPT and olivary hypertrophy was reviewed with specific interest regarding causes, diagnostic procedures, physiopathology and therapies. RECENT FINDINGS: OPT is associated with inferior olivary hypertrophy, and recent findings have provided a better understanding of its intimate mechanisms. A dual-mechanism model, combining an oscillator (inferior olive) and a modulator/amplifier (cerebellum), best explains the development of OPT. Electrotonic coupling and specific Ca channels contribute to oscillations of inferior olivary nucleus neurons in OPT. Improvement of visual symptoms can be achieved with oral gabapentin or memantine. SUMMARY: Both the neuronal circuitry and the physiopathology of OPT are now better understood. This opens up an era of specific therapy for this rare cause of disabling oscillopsia.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
PURPOSE: To improve the traditional Nyquist ghost correction approach in echo planar imaging (EPI) at high fields, via schemes based on the reversal of the EPI readout gradient polarity for every other volume throughout a functional magnetic resonance imaging (fMRI) acquisition train. MATERIALS AND METHODS: An EPI sequence in which the readout gradient was inverted every other volume was implemented on two ultrahigh-field systems. Phantom images and fMRI data were acquired to evaluate ghost intensities and the presence of false-positive blood oxygenation level-dependent (BOLD) signal with and without ghost correction. Three different algorithms for ghost correction of alternating readout EPI were compared. RESULTS: Irrespective of the chosen processing approach, ghosting was significantly reduced (up to 70% lower intensity) in both rat brain images acquired on a 9.4T animal scanner and human brain images acquired at 7T, resulting in a reduction of sources of false-positive activation in fMRI data. CONCLUSION: It is concluded that at high B(0) fields, substantial gains in Nyquist ghost correction of echo planar time series are possible by alternating the readout gradient every other volume.
Resumo:
Astrocytes fulfill a central role in regulating K+ and glutamate, both released by neurons into the extracellular space during activity. Glial glutamate uptake is a secondary active process that involves the influx of three Na+ ions and one proton and the efflux of one K+ ion. Thus, intracellular K+ concentration ([K+]i) is potentially influenced both by extracellular K+ concentration ([K+]o) fluctuations and glutamate transport in astrocytes. We evaluated the impact of these K+ ion movements on [K+]i in primary mouse astrocytes by microspectrofluorimetry. We established a new noninvasive and reliable approach to monitor and quantify [K+]i using the recently developed K+ sensitive fluorescent indicator Asante Potassium Green-1 (APG-1). An in situ calibration procedure enabled us to estimate the resting [K+]i at 133±1 mM. We first investigated the dependency of [K+]i levels on [K+]o. We found that [K+]i followed [K+]o changes nearly proportionally in the range 3-10 mM, which is consistent with previously reported microelectrode measurements of intracellular K+ concentration changes in astrocytes. We then found that glutamate superfusion caused a reversible drop of [K+]i that depended on the glutamate concentration with an apparent EC50 of 11.1±1.4 µM, corresponding to the affinity of astrocyte glutamate transporters. The amplitude of the [K+]i drop was found to be 2.3±0.1 mM for 200 µM glutamate applications. Overall, this study shows that the fluorescent K+ indicator APG-1 is a powerful new tool for addressing important questions regarding fine [K+]i regulation with excellent spatial resolution.
Resumo:
The kinetics of binding of a glycolipid-anchored protein (the promastigote surface protease, PSP) to planar lecithin bilayers is studied by an integrated optics technique, in which the bilayer membrane is supported on an optical wave guide and the phase velocities of guided light modes in the wave guide are measured. From these velocities, the optical parameters of the membrane and PSP layers deposited on the waveguide are determined, yielding in particular the mass of PSP bound to the membrane, which is followed in real time. From a comparison of the binding rates of PSP and PSP from which the lipid moiety has been removed, it is shown that the lipid moiety plays a key role in anchoring the protein to the membrane. Specific and nonspecific binding of antibodies to membrane-anchored PSP is also investigated. As little as a fifth of a monolayer of PSP is sufficient to suppress the appreciable nonspecific binding of antibodies to the membrane.