113 resultados para Linear variable filters
Resumo:
In addition to the importance of sample preparation and extract separation, MS detection is a key factor in the sensitive quantification of large undigested peptides. In this article, a linear ion trap MS (LIT-MS) and a triple quadrupole MS (TQ-MS) have been compared in the detection of large peptides at subnanomolar concentrations. Natural brain natriuretic peptide, C-peptide, substance P and D-Junk-inhibitor peptide, a full D-amino acid therapeutic peptide, were chosen. They were detected by ESI and simultaneous MS(1) and MS(2) acquisitions. With direct peptide infusion, MS(2) spectra revealed that fragmentation was peptide dependent, milder on the LIT-MS and required high collision energies on the TQ-MS to obtain high-intensity product ions. Peptide adsorption on surfaces was overcome and peptide dilutions ranging from 0.1 to 25 nM were injected onto an ultra high-pressure LC system with a 1 mm id analytical column and coupled with the MS instruments. No difference was observed between the two instruments when recording in LC-MS(1) acquisitions. However, in LC-MS(2) acquisitions, a better sensitivity in the detection of large peptides was observed with the LIT-MS. Indeed, with the three longer peptides, the typical fragmentation in the TQ-MS resulted in a dramatic loss of sensitivity (> or = 10x).
Resumo:
We describe an improved multiple-locus variable-number tandem-repeat (VNTR) analysis (MLVA) scheme for genotyping Staphylococcus aureus. We compare its performance to those of multilocus sequence typing (MLST) and spa typing in a survey of 309 strains. This collection includes 87 epidemic methicillin-resistant S. aureus (MRSA) strains of the Harmony collection, 75 clinical strains representing the major MLST clonal complexes (CCs) (50 methicillin-sensitive S. aureus [MSSA] and 25 MRSA), 135 nasal carriage strains (133 MSSA and 2 MRSA), and 13 published S. aureus genome sequences. The results show excellent concordance between the techniques' results and demonstrate that the discriminatory power of MLVA is higher than those of both MLST and spa typing. Two hundred forty-two genotypes are discriminated with 14 VNTR loci (diversity index, 0.9965; 95% confidence interval, 0.9947 to 0.9984). Using a cutoff value of 45%, 21 clusters are observed, corresponding to the CCs previously defined by MLST. The variability of the different tandem repeats allows epidemiological studies, as well as follow-up of the evolution of CCs and the identification of potential ancestors. The 14 loci can conveniently be analyzed in two steps, based upon a first-line simplified assay comprising a subset of 10 loci (panel 1) and a second subset of 4 loci (panel 2) that provides higher resolution when needed. In conclusion, the MLVA scheme proposed here, in combination with available on-line genotyping databases (including http://mlva.u-psud.fr/), multiplexing, and automatic sizing, can provide a basis for almost-real-time large-scale population monitoring of S. aureus.
Resumo:
PURPOSE: The longitudinal relaxation rate (R1 ) measured in vivo depends on the local microstructural properties of the tissue, such as macromolecular, iron, and water content. Here, we use whole brain multiparametric in vivo data and a general linear relaxometry model to describe the dependence of R1 on these components. We explore a) the validity of having a single fixed set of model coefficients for the whole brain and b) the stability of the model coefficients in a large cohort. METHODS: Maps of magnetization transfer (MT) and effective transverse relaxation rate (R2 *) were used as surrogates for macromolecular and iron content, respectively. Spatial variations in these parameters reflected variations in underlying tissue microstructure. A linear model was applied to the whole brain, including gray/white matter and deep brain structures, to determine the global model coefficients. Synthetic R1 values were then calculated using these coefficients and compared with the measured R1 maps. RESULTS: The model's validity was demonstrated by correspondence between the synthetic and measured R1 values and by high stability of the model coefficients across a large cohort. CONCLUSION: A single set of global coefficients can be used to relate R1 , MT, and R2 * across the whole brain. Our population study demonstrates the robustness and stability of the model. Magn Reson Med, 2014. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. Magn Reson Med 73:1309-1314, 2015. © 2014 Wiley Periodicals, Inc.
Resumo:
Aims :¦Several studies have questioned the validity of separating the diagnosis of alcohol abuse from that of alcohol dependence, and the DSM-5 task force has proposed combining the criteria from these two diagnoses to assess a single category of alcohol use disorders (AUD). Furthermore, the DSM-5 task force has proposed including a new 2-symptom threshold and a severity scale based on symptom counts for the AUD diagnosis. The current study aimed to examine these modifications in a large population-based sample.¦Method :¦Data stemmed from an adult sample (N=2588 ; mean age 51.3 years (s.d.: 0.2), 44.9% female) of current and lifetime drinkers from the PsyCoLaus study, conducted in the Lausanne area in Switzerland. AUDs and validating variables were assessed using a semi-structured diagnostic interview for the assessment of alcohol¦and other major psychiatric disorders. First, the adequacy of the proposed 2- symptom threshold was tested by comparing threshold models at each possible cutoff and a linear model, in relation to different validating variables. The model with the smallest Akaike Criterion Information (AIC) value was established as the best¦model for each validating variable. Second, models with varying subsets of individual AUD symptoms were created to assess the associations between each symptom and the validating variables. The subset of symptoms with the smallest AIC value was established as the best subset for each validator.¦Results :¦1) For the majority of validating variables, the linear model was found to be the best fitting model. 2) Among the various subsets of symptoms, the symptoms most frequently associated with the validating variables were : a) drinking despite having knowledge of a physical or psychological problem, b) having had a persistent desire or unsuccessful efforts to cut down or control drinking and c) craving. The¦least frequent symptoms were : d) drinking in larger amounts or over a longer period than was intended, e) spending a great deal of time in obtaining, using or recovering from alcohol use and f) failing to fulfill major role obligations.¦Conclusions :¦The proposed DSM-5 2-symptom threshold did not receive support in our data. Instead, a linear AUD diagnosis was supported with individuals receiving an increasingly severe AUD diagnosis. Moreover, certain symptoms were more frequently associated with the validating variables, which suggests that these¦symptoms should be considered as more severe.
Resumo:
In humans, NK receptors are expressed by natural killer cells and some T cells, the latter of which are preferentially alphabetaTCR+ CD8+ cytolytic T lymphocytes (CTL). In this study we analyzed the expression of nine NK receptors (p58.1, p58.2, p70, p140, ILT2, NKRP1A, ZIN176, CD94 and CD94/NKG2A) in PBL from both healthy donors and melanoma patients. The percentages of NK receptor-positive T cells (NKT cells) varied strongly, and this variation was more important between individual patients than between individual healthy donors. In all the individuals, the NKT cells were preferentially CD28-, and a significant correlation was found between the percentage of CD28- T cells and the percentage of NK receptor+ T cells. Based on these data and the known activated phenotype of CD28- T cells, we propose that the CD28- CD8+ T cell pool represents or contains the currently active CTL population, and that the frequent expression of NK receptors reflects regulatory mechanisms modulating the extent of CTL effector function. Preliminary results indicate that some tumor antigen-specific T cells may indeed be CD28- and express NK receptors in vivo.
Resumo:
OBJECTIVE: (1) To quantify wear of two different denture tooth materials in vivo with two study designs, (2) to relate tooth variables to vertical loss. METHODS: Two different denture tooth materials had been used (experimental material=test; DCL=control). In study 1 (split-mouth, 6 test centers) 60 subjects received complete dentures, in study 2 (two-arm, 1 test center) 29 subjects. In study 1 the mandibular dentures were supported by implants in 33% of the subjects, in study 2 only in 3% of the subjects. Impressions of the dentures were taken and poured with improved stone at baseline and after 6, 12, 18 and 24 months. Each operator evaluated the wear subjectively. Wear analysis was carried out with a laser scanning device. Maximal vertical loss of the attrition zones was calculated for each tooth cusp and tooth. A mixed linear model was used to statistically analyse the logarithmically transformed wear data. RESULTS: Due to drop-outs and unmatchable casts, only 47 subjects of study 1 and 14 of study 2 completed the 2-year recall. Overall, 75% of all teeth present could be analysed. There was no statistically difference in the overall wear between the test and control material for either study 1 or study 2. The relative increase in wear over time was similar in both study designs. However, a strong subject effect and center effect were observed. The fixed factors included in the model (time, tooth, center, etc.) accounted for 43% of the variability, whereas the random subject effect accounted for another 30% of the variability, leaving about 28% of unexplained variability. More wear was consistently recorded in the maxillary teeth compared to the mandibular teeth and in the first molar teeth compared to the premolar teeth and the second molars. Likewise, the supporting cusps showed more wear than the non-supporting cusps. The amount of wear did not depend on whether or not the lower dentures were supported by implants. The subjective wear was correct in about 67% of the cases if it is postulated that a wear difference of 100μm should be subjectively detectable. SIGNIFICANCE: The clinical wear of denture teeth is highly variable with a strong patient effect. More wear can be expected in maxillary denture teeth compared to mandibular teeth, first molars compared to premolars and supported cusps compared to non-supported cusps. Laboratory data on the wear of denture tooth materials may not be confirmed in well-structured clinical trials probably due to the large inter-individual variability.
Resumo:
In dynamic models of energy allocation, assimilated energy is allocated to reproduction, somatic growth, maintenance or storage, and the allocation pattern can change with age. The expected evolutionary outcome is an optimal allocation pattern, but this depends on the environment experienced during the evolutionary process and on the fitness costs and benefits incurred by allocating resources in different ways. Here we review existing treatments which encompass some of the possibilities as regards constant or variable environments and their predictability or unpredictability, and the ways in which production rates and mortality rates depend on body size and composition and age and on the pattern of energy allocation. The optimal policy is to allocate resources where selection pressures are highest, and simultaneous allocation to several body subsystems and reproduction can be optimal if these pressures are equal. This may explain balanced growth commonly observed during ontogeny. Growth ceases at maturity in many models; factors favouring growth after maturity include non-linear trade-offs, variable season length, and production and mortality rates both increasing (or decreasing) functions of body size. We cannot yet say whether these are sufficient to account for the many known cases of growth after maturity and not all reasonable models have yet been explored. Factors favouring storage are also reviewed.
Resumo:
Significant progress has been made with regard to the quantitative integration of geophysical and hydrological data at the local scale. However, extending the corresponding approaches to the regional scale represents a major, and as-of-yet largely unresolved, challenge. To address this problem, we have developed an upscaling procedure based on a Bayesian sequential simulation approach. This method is then applied to the stochastic integration of low-resolution, regional-scale electrical resistivity tomography (ERT) data in combination with high-resolution, local-scale downhole measurements of the hydraulic and electrical conductivities. Finally, the overall viability of this upscaling approach is tested and verified by performing and comparing flow and transport simulation through the original and the upscaled hydraulic conductivity fields. Our results indicate that the proposed procedure does indeed allow for obtaining remarkably faithful estimates of the regional-scale hydraulic conductivity structure and correspondingly reliable predictions of the transport characteristics over relatively long distances.
Resumo:
The noise power spectrum (NPS) is the reference metric for understanding the noise content in computed tomography (CT) images. To evaluate the noise properties of clinical multidetector (MDCT) scanners, local 2D and 3D NPSs were computed for different acquisition reconstruction parameters.A 64- and a 128-MDCT scanners were employed. Measurements were performed on a water phantom in axial and helical acquisition modes. CT dose index was identical for both installations. Influence of parameters such as the pitch, the reconstruction filter (soft, standard and bone) and the reconstruction algorithm (filtered-back projection (FBP), adaptive statistical iterative reconstruction (ASIR)) were investigated. Images were also reconstructed in the coronal plane using a reformat process. Then 2D and 3D NPS methods were computed.In axial acquisition mode, the 2D axial NPS showed an important magnitude variation as a function of the z-direction when measured at the phantom center. In helical mode, a directional dependency with lobular shape was observed while the magnitude of the NPS was kept constant. Important effects of the reconstruction filter, pitch and reconstruction algorithm were observed on 3D NPS results for both MDCTs. With ASIR, a reduction of the NPS magnitude and a shift of the NPS peak to the low frequency range were visible. 2D coronal NPS obtained from the reformat images was impacted by the interpolation when compared to 2D coronal NPS obtained from 3D measurements.The noise properties of volume measured in last generation MDCTs was studied using local 3D NPS metric. However, impact of the non-stationarity noise effect may need further investigations.
Resumo:
Introduction: In children with cystic fibrosis (CF), low immunoglobulin (IgG) levels have been reported to be associated with significantly less severe lung disease. However, decreased IgG can be a sign for common variable immunodeficiency (CVID) and affect clinical outcome. The aim of this study was to analyze clinical and serological data of patients having low IgG levels in routine blood tests at annual assessment, particularly their antibody response to polysaccharide antigens. Method: Retrospective chart review of demographic data of CF patients followed at the pediatric CF clinic throughout 2009. Clinical parameters (genotype, pancreas sufficiency, FEV1), presence of Pseudomonas aeruginosa (PA) and number of exacerbations per year were correlated with immunoglobulin and vaccination antibodies levels (antibodies to pneumococcal serotypes 14, 19, 23, 1, 5 and 7F measured by enzyme-linked immune-sorbent assay). Results: 4 out of 60 patients (6.7%) had lower IgG-levels for age. Ages ranged from 1 year 8 months to 11 years, 2 boys, 2 girls. Three patients were delF508 homozygotes, one heterozygote composite delF508/G542X. All were pancreatic insufficient. FEV1 ranged from 74 to 108%. One patient never had colonization by PA, 2 had intermittent PA colonization and one was chronically infected. After conjugated vaccination all patients had protective antibodies against serotypes 14, 19, 23F. For serotypes not included in the vaccine, only one patient had protective titers for 1 out of 3 serotypes. None of the patients had received unconjugated pneumococcal vaccine. There was no significant clinical difference in FEV1, PA colonization or number of exacerbations according to IgG and vaccination antibody levels. Conclusion: Cystic Fibrosis patients with low immunoglobulin levels have normal antibody response to protein antigens. However, despite recurrent infections, there seems to be delayed or deficient antibody response to polysaccharide antigens. Prospective studies are needed to evaluate the development of polysaccharide antibody responses in CF-patients to monitor for CVID. With early detection of CF by newborn screening program, long term follow up could be started early in childhood.
Resumo:
A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.
Resumo:
Objectives: The purpose of this study was to analyze the debris captured in the distal protection filters used during carotid artery stenting (CAS). Background: CAS is an option available to high-risk patients requiring revascularization. Filters are suggested for optimal stroke prevention during CAS. Methods: From May 2005 to June 2007, filters from 59 asymptomatic patients who underwent CAS were collected and sent to a specialized laboratory for light-microscope and histological analysis. Peri- and postprocedural outcomes were assessed during 1-year follow-up. Results: On the basis of biomedical imaging of the filter debris, the captured material could not be identified as embolized particles from the carotid plaque. On histological analysis the debris consisted mainly of red blood cell aggregates and/ or platelets, occasionally accompanied by granulocytes. We found no consistent histological evidence of embolized particles originating from atherosclerotic plaques. Post-procedure, three neurological events were reported: two (3.4%) transient ischemic attacks (TIA) and one (1.7%) ipsilateral minor stroke. Conclusion: The filters used during CAS in asymptomatic patients planned for cardiac surgery often remained empty. These findings may be explained by assuming that asymptomatic patients feature a different atherosclerotic plaque composition or stabilization through antiplatelet medication. Larger, randomized trials are clearly warranted, especially in the asymptomatic population. © 2012 Wiley Periodicals, Inc.