94 resultados para Light emitting device
Resumo:
Phytochromes are red/far-red photosensors that regulate numerous developmental programs in plants. Among them, phytochrome A (phyA) is essential to enable seedling de-etiolation under continuous far-red (FR) light, a condition that mimics the environment under a dense canopy. The ecological relevance of this response is demonstrated by the high mortality rate of phyA mutant plants that germinate in deep vegetational shade. phyA signaling involves direct interaction of the photoreceptor with phytochrome-interacting factors PIF1 and PIF3, members of the bHLH transcription factor family. Here we investigated the involvement of PIF4 and PIF5 in phyA signaling, and found that they redundantly control de-etiolation in FR light. The pif4 pif5 double mutant is hypersensitive to low fluence rates of FR light. This phenotype is dependent on FR light perception by phyA, but does not rely on alterations in the phyA level. Our microarray analysis shows that PIF4 and PIF5 are part of an inhibitory mechanism that represses the expression of some light-responsive genes in the dark, and that they are also needed for full expression of several growth-related genes in the light. Unlike PIF1 and PIF3, PIF4 and PIF5 are not degraded in response to FR light, indicating that they are light-regulated by a different mechanism. Our genetic analysis suggests that this is achieved through sequestration of these PIFs by the closely related bHLH transcription factor HFR1 (long hypocotyl in FR light).
Resumo:
CD44 is the major cell-surface receptor for hyaluronan, which is implicated in cell-cell and cell-matrix adhesion, cell migration, and signaling. Studies have shown that CD44-dependent migration requires CD44 to be shed from the cell surface and that matrix metalloproteinase-mediated cleavage may provide an underlying mechanism. However, the full spectrum of proteases that may participate in CD44 shedding has yet to be defined. In this issue, Anderegg et al. demonstrate that ADAM10, but not ADAM17 or MMP14, mediates constitutive shedding of CD44 in human melanoma cells and that knockdown of ADAM10 blocks the antiproliferative activity of the soluble proteolytic cleavage product of CD44.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
The OLS estimator of the intergenerational earnings correlation is biased towards zero, while the instrumental variables estimator is biased upwards. The first of these results arises because of measurement error, while the latter rests on the presumption that the education of the parent family is an invalid instrument. We propose a panel data framework for quantifying the asymptotic biases of these estimators, as well as a mis-specification test for the IV estimator. [Author]
Resumo:
BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.
Resumo:
Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.
Resumo:
An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
This article analyses and discusses issues that pertain to the choice of relevant databases for assigning values to the components of evaluative likelihood ratio procedures at source level. Although several formal likelihood ratio developments currently exist, both case practitioners and recipients of expert information (such as judiciary) may be reluctant to consider them as a framework for evaluating scientific evidence in context. The recent ruling R v T and ensuing discussions in many forums provide illustrative examples for this. In particular, it is often felt that likelihood ratio-based reasoning amounts to an application that requires extensive quantitative information along with means for dealing with technicalities related to the algebraic formulation of these approaches. With regard to this objection, this article proposes two distinct discussions. In a first part, it is argued that, from a methodological point of view, there are additional levels of qualitative evaluation that are worth considering prior to focusing on particular numerical probability assignments. Analyses will be proposed that intend to show that, under certain assumptions, relative numerical values, as opposed to absolute values, may be sufficient to characterize a likelihood ratio for practical and pragmatic purposes. The feasibility of such qualitative considerations points out that the availability of hard numerical data is not a necessary requirement for implementing a likelihood ratio approach in practice. It is further argued that, even if numerical evaluations can be made, qualitative considerations may be valuable because they can further the understanding of the logical underpinnings of an assessment. In a second part, the article will draw a parallel to R v T by concentrating on a practical footwear mark case received at the authors' institute. This case will serve the purpose of exemplifying the possible usage of data from various sources in casework and help to discuss the difficulty associated with reconciling the depth of theoretical likelihood ratio developments and limitations in the degree to which these developments can actually be applied in practice.
Resumo:
The basic photosynthetic unit containing the reaction centre and the light-harvesting I complex (RC-LHI) of the purple non-sulphur bacterium Rhodospirillum rubrum was purified and reconstituted into two-dimensional (2D) membrane crystals. Transmission electron microscopy using conventional techniques and cryoelectron microscopy of the purified single particles and of 2D crystals yielded a projection of the RC-LHI complex at a resolution of at least 1.6 nm. In this projection the LHI ring appears to have a square symmetry and packs in a square crystal lattice. The square geometry of the LHI ring was observed also in images of single isolated particles of the RC-LHI complex. However, although the LHI units are packed identically within the crystal lattice, a new rotational analysis developed here showed that the reaction centres take up one of four possible orientations within the ring. This fourfold disorder supports our interpretation of a square ring symmetry and suggests that a hitherto undetected component may be present within the photosynthetic unit.
Resumo:
ABSTRACTIn normal tissues, a balance between pro- and anti-angiogenic factors tightly controls angiogenesis. Alterations of this balance may have pathological consequences. For instance, concerning the retina, the vascular endothelial growth factor (VEGF) is a potent pro-angiogenic factor, and has been identified has a key player during ocular neovascularization implicated in a variety of retinal diseases. In the exudative form (wet-form) of age-related macular degeneration (AMD), neovascularizations occurring from the choroidal vessels are responsible for a quick and dramatic loss of visual acuity. In diabetic retinopathy and retinopathy of prematurity, sprouting from the retinal vessels leads to vision loss. Furthermore, the aging of the population, the increased- prevalence of diabetes and the better survival rate of premature infants will lead to an increasing rate of these conditions. In this way, anti-VEGF strategy represents an important therapeutic target to treat ocular neovascular disorders.In addition, the administration of Pigmented Epithelial growth factor, a neurotrophic and an anti- angiogenic factor, prevents photoreceptor cell death in a model of retinal degeneration induced by light. Previous results analyzing end point morphology reveal that the light damage (LD) model is used to mimic retinal degenerations arising from environmental insult, as well as aging and genetic disease such as advanced atrophic AMD. Moreover, light has been identified as a co-factor in a number of retinal diseases, speeding up the degeneration process. This protecting effect of PEDF in the LD retina raises the possibility of involvement of the balance between pro- and anti-angiogenic factors not only for angiogenesis, but also in cell survival and maintenance.The aim of the work presented here was to evaluate the importance of this balance in neurodegenerative processes. To this aim, a model of light-induced retinal degeneration was used and characterized, mainly focusing on factors simultaneously controlling neuron survival and angiogenesis, such as PEDF and VEGF.In most species, prolonged intense light exposure can lead to photoreceptor cell damage that can progress to cell death and vision loss. A protocol previously described to induce retinal degeneration in Balb/c mice was used. Retinas were characterized at different time points after light injury through several methods at the functional and molecular levels. Data obtained confirmed that toxic level of light induce PR cell death. Variations were observed in VEGF pathway players in both the neural retina and the eye-cup containing the retinal pigment epithelium (RPE), suggesting a flux of VEGF from the RPE towards the neuroretina. Concomitantly, the integrity of the outer blood-retinal-barrier (BRB) was altered, leading to extravascular albumin leakage from the choroid throughout the photoreceptor layer.To evaluate the importance of VEGF during light-induced retinal degeneration process, a lentiviral vector encoding the cDNA of a single chain antibody directed against all VEGF-A isoforms was developed (LV-V65). The bioactivity of this vector to block VEGF was validated in a mouse model of laser-induced choroidal neovascularization mediated by VEGF upregulation. The vector was then used in the LD model. The administration of the LV-V65 contributed to the maintenance of functional photoreceptors, which was assessed by ERG recording, visual acuity measurement and histological analyses. At the RPE level, the BRB integrity was preserved as shown by the absence of albumin leakage and the maintenance of RPE cell cohesion.These results taken together indicate that the VEGF is a mediator of light induced PR degeneration process and confirm the crucial role of the balance between pro- and anti-angiogenic factors in the PR cell survival. This work also highlights the prime importance of BRB integrity and functional coupling between RPE and PR cells to maintain the PR survival. VEGF dysregulation was already shown to be involved in wet AMD forms and our study suggests that VEGF dysregulation may also occur at early stages of AMD and could thus be a potential therapeutic target for several RPE related diseases.RESUMEDans les différents tissues de l'organisme, l'angiogenèse est strictement contrôlée par une balance entre les facteurs pro- et anti-angiogéniques. Des modifications survenant dans cette balance peuvent engendrer des conséquences pathologiques. Par exemple, concernant la rétine, le facteur de croissance de l'endothélium vasculaire (VEGF) est un facteur pro-angiogénique important. Ce facteur a été identifié comme un acteur majeur dans les néovascularisations oculaires et les processus pathologiques angiogéniques survenant dans l'oeil et responsables d'une grande variété de maladies rétiniennes. Dans la forme humide de la dégénérescence maculaire liée à l'âge (DMLA), la néovascularisation choroïdienne est responsable de la perte rapide et brutale de l'acuité visuelle chez les patients affectés. Dans la rétinopathie diabétique et celle lié à la prématurité, l'émergence de néovaisseaux rétiniens est la cause de la perte de la vision. Les néovascularisations oculaires représentent la principale cause de cécité dans les pays développés. De plus, l'âge croissant de la population, la progression de la prévalence du diabète et la meilleure survie des enfants prématurés mèneront sans doute à l'augmentation de ces pathologies dans les années futures. Dans ces conditions, les thérapies anti- angiogéniques visant à inhiber le VEGF représentent une importante cible thérapeutique pour le traitement de ces pathologies.Plusieurs facteurs anti-angiogéniques ont été identifiés. Parmi eux, le facteur de l'épithélium pigmentaire (PEDF) est à la fois un facteur neuro-trophique et anti-angiogénique, et l'administration de ce facteur au niveau de la rétine dans un modèle de dégénérescence rétinienne induite par la lumière protège les photorécepteurs de la mort cellulaire. Des études antérieures basées sur l'analyse morphologique ont révélé que les modifications survenant lors de la dégénération induite suite à l'exposition à des doses toxiques de lumière représente un remarquable modèle pour l'étude des dégénérations rétiniennes suite à des lésions environnementales, à l'âge ou encore aux maladies génétiques telle que la forme atrophique avancée de la DMLA. De plus, la lumière a été identifiée comme un co-facteur impliqué dans un grand nombre de maladies rétiniennes, accélérant le processus de dégénération. L'effet protecteur du PEDF dans les rétines lésées suite à l'exposition de des doses toxiques de lumière suscite la possibilité que la balance entre les facteurs pro- et anti-angiogéniques soit impliquée non seulement dans les processus angiogéniques, mais également dans le maintient et la survie des cellules.Le but de ce projet consiste donc à évaluer l'implication de cette balance lors des processus neurodégénératifs. Pour cela, un modèle de dégénération induite par la lumière à été utilisé et caractérisé, avec un intérêt particulier pour les facteurs comme le PEDF et le VEGF contrôlant simultanément la survie des neurones et l'angiogenèse.Dans la plupart des espèces, l'exposition prolongée à une lumière intense peut provoquer des dommages au niveau des cellules photoréceptrices de l'oeil, qui peut mener à leur mort, et par conséquent à la perte de la vision. Un protocole préalablement décrit a été utilisé pour induire la dégénération rétinienne dans les souris albinos Balb/c. Les rétines ont été analysées à différents moments après la lésion par différentes techniques, aussi bien au niveau moléculaire que fonctionnel. Les résultats obtenus ont confirmé que des doses toxiques de lumière induisent la mort des photorécepteurs, mais altèrent également la voie de signalisation du VEGF, aussi bien dans la neuro-rétine que dans le reste de l'oeil, contenant l'épithélium pigmentaire (EP), et suggérant un flux de VEGF provenant de ΙΈΡ en direction de la neuro-rétine. Simultanément, il se produit une altération de l'intégrité de la barrière hémato-rétinienne externe, menant à la fuite de protéine telle que l'albumine, provenant de la choroïde et retrouvée dans les compartiments extravasculaires de la rétine, telle que dans la couche des photorécepteurs.Pour déterminer l'importance et le rôle du VEGF, un vecteur lentiviral codant pour un anticorps neutralisant dirigée contre tous les isoformes du VEGF a été développé (LV-V65). La bio-activité de ce vecteur a été testé et validée dans un modèle de laser, connu pour induire des néovascularisations choroïdiennes chez la souris suite à l'augmentation du VEGF. Ce vecteur a ensuite été utilisé dans le modèle de dégénération induite par la lumière. Les résultats des électrorétinogrammes, les mesures de l'acuité visuelle et les analyses histologiques ont montré que l'injection du LV-V65 contribue à la maintenance de photorécepteurs fonctionnels. Au niveau de l'EP, l'absence d'albumine et la maintenance des jonctions cellulaires des cellules de l'EP ont démontré que l'intégrité de la barrière hémato-rétinienne externe est préservée suite au traitement.Par conséquent, tous les résultats obtenus indiquent que le VEGF est un médiateur important impliquée dans le processus de dégénération induit par la lumière et confirme le rôle cruciale de la balance entre les facteurs pro- et anti-angiogéniques dans la survie des photorécepteurs. Cette étude révèle également l'importance de l'intégrité de la barrière hémato-rétinienne et l'importance du lien fonctionnel et structurel entre l'EP et les photorécepteurs, essentiel pour la survie de ces derniers. Par ailleurs, Cette étude suggère que des dérèglements au niveau de l'équilibre du VEGF ne sont pas seulement impliqués dans la forme humide de la DMLA, comme déjà démontré dans des études antérieures, mais pourraient également contribuer et survenir dans des formes précoces de la DMLA, et par conséquent le VEGF représente une cible thérapeutique potentielle pour les maladies associées à des anomalies au niveau de l'EP.
Resumo:
INTRODUCTION: Intraosseous access is increasingly recognised as an effective alternative vascular access to peripheral venous access. We aimed to prospectively study the patients receiving prehospital intraosseous access with the EZ-IO(®), and to compare our results with those of the available literature. METHODS: Every patient who required an intraosseous access with the EZ-IO from January 1st, 2009 to December 31st, 2011 was included. The main data collected were: age, sex, indication for intraosseous access, localisation of insertion, success rate, drugs and fluids administered, and complications. All published studies concerning the EZ-IO device were systematically searched and reviewed for comparison. RESULTS: Fifty-eight patients representing 60 EZ-IO procedures were included. Mean age was 47 years (range 0.5-91), and the success rate was 90%. The main indications were cardiorespiratory arrest (74%), major trauma (12%), and shock (5%). The anterior tibia was the main route. The main drugs administered were adrenaline (epinephrine), atropine and amiodarone. No complications were reported. We identified 30 heterogeneous studies representing 1603 EZ-IO insertions. The patients' characteristics and success rate were similar to our study. Complications were reported in 13 cases (1.3%). CONCLUSION: The EZ-IO provides an effective way to achieve vascular access in the pre-hospital setting. Our results were similar to the cumulative results of all studies involving the use of the EZ-IO, and that can be used for comparison for further studies.
Resumo:
Light food and beverages are increasing on the market for many years, first for economic reasons and, more and more for aesthetisme, however without aimed a defined population. The interest of these products is not evident, reason why it is difficult to get a clear and objective opinion without being influenced by marketing messages. Under what circumstances can they be a solution? Can we advise them? Do they have an influence in the loss or weight control? This article offers some thoughts and suggestions on the use of these specific products.
Resumo:
In order to evaluate the influence of continental crustal rocks on trace element budgets of serpentinized peridotites incorporated into the continental crust, we have analyzed the chemical composition of whole rock samples and minerals of the Geisspfad ultramafic complex (Swiss-Italian Alps). This complex represents a relict oceanic succession composed of serpentinites, ophicarbonates and metabasic rocks, emplaced into crustal gneisses during Alpine collision. Following peak metamorphic amphibolite facies conditions, fluid flow modified some of the trace element contents of ophicarbonates and deformed serpentinites close to the contact with country rocks. The fluid originated from the surrounding continental crustal rocks as documented by the increase of Pb in the serpentinites, and by the strongly negative all) values (-112 parts per thousand) of some ultramafic rocks close to the contact with surrounding gneisses. Little or no modification of the fluid mobile elements Li, B or U was observed in the serpentinite. In-situ analysis of light elements of serpentinite minerals indicate redistribution of light elements coupled to changes of mineral modes towards the outer 100-150 m of the massif. In the centre of the massif, Li is preferentially concentrated in olivine, while Be and B are hosted by tremolite. In contrast, at the outer rim of the massif, Li and Be are preferentially incorporated into diopside, and B into antigorite. This redistribution of light elements among the different minerals is visible in the serpentinite, at a maximum distance of -100-150 m from the ophicarbonate-metabasite contact. Our results show that interaction of ultramafic rocks and crust-derived fluids can be easily detected by studies of Pb and partial derivative D in whole rocks. We argue that small ultramafic bodies potentially record an emplacement-related trace element signature, and that crustal light element values in ultramafic rocks are not necessarily derived from a subducting slab. (C) 2008 Elsevier B.V. All rights reserved.