87 resultados para semiconductor measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The increase of apparent diffusion coefficient (ADC) in treated hepatic malignancies compared to pre-therapeutic values has been interpreted as treatment success; however, the variability of ADC measurements remains unknown. Furthermore, ADC has been usually measured in the whole lesion, while measurements should be probably centered on the area with the most restricted diffusion (MRDA) as it represents potential tumoral residue. Our objective was to compare the inter/intraobserver variability of ADC measurements in the whole lesion and in MRDA. Material and methods: Forty patients previously treated with chemoembolization or radiofrequency were evaluated (20 on 1.5T and 20 on 3.0T). After consensual agreement on the best ADC image, two readers measured the ADC values using separate regions of interest that included the whole lesion and the whole MRDA without exceeding their borders. The same measurements were repeated two weeks later. Spearman test and the Bland-Altman method were used. Results: Interobserver correlation in ADC measurements in the whole lesion and MRDA was as follows: 0.962 and 0.884. Intraobserver correlation was, respectively, 0.992 and 0.979. Interobserver limits of variability (mm2/sec*10-3) were between -0.25/+0.28 in the whole lesion and between -0.51/+0.46 in MRDA. Intraobserver limits of variability were, respectively: -0.25/+0.24 and -0.43/+0.47. Conclusion: We observed a good inter/intraobserver correlation in ADC measurements. Nevertheless, a limited variability does exist, and it should be considered when interpreting ADC values of hepatic malignancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study telomere length dynamics in hematopoietic cells with age, we analyzed the average length of telomere repeat sequences in diverse populations of nucleated blood cells. More than 500 individuals ranging in age from 0 to 90 yr, including 36 pairs of monozygous and dizygotic twins, were analyzed using quantitative fluorescence in situ hybridization and flow cytometry. Granulocytes and naive T cells showed a parallel biphasic decline in telomere length with age that most likely reflected accumulated cell divisions in the common precursors of both cell types: hematopoietic stem cells. Telomere loss was very rapid in the first year, and continued for more than eight decades at a 30-fold lower rate. Memory T cells also showed an initial rapid decline in telomere length with age. However, in contrast to naive T cells, this decline continued for several years, and in older individuals lymphocytes typically had shorter telomeres than did granulocytes. Our findings point to a dramatic decline in stem cell turnover in early childhood and support the notion that cell divisions in hematopoietic stem cells and T cells result in loss of telomeric DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant progress has been made with regard to the quantitative integration of geophysical and hydrological data at the local scale. However, extending the corresponding approaches to the regional scale represents a major, and as-of-yet largely unresolved, challenge. To address this problem, we have developed an upscaling procedure based on a Bayesian sequential simulation approach. This method is then applied to the stochastic integration of low-resolution, regional-scale electrical resistivity tomography (ERT) data in combination with high-resolution, local-scale downhole measurements of the hydraulic and electrical conductivities. Finally, the overall viability of this upscaling approach is tested and verified by performing and comparing flow and transport simulation through the original and the upscaled hydraulic conductivity fields. Our results indicate that the proposed procedure does indeed allow for obtaining remarkably faithful estimates of the regional-scale hydraulic conductivity structure and correspondingly reliable predictions of the transport characteristics over relatively long distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the influence of pore space characteristics on the hydraulic conductivity and spectral induced polarization (SIP) response is critical for establishing relationships between the electrical and hydrological properties of surficial sedimentary deposits. Here, we present the results of laboratory SIP measurements on saturated quartz samples with granulometric characteristics ranging from fine sand to fine gravel. We alter the pore characteristics using three principal methods: (i) variation of the grain sizes, (ii) changing the degree of compaction, and (iii) changing the level of sorting. We then examine how these changes affect both the SIP response and the hydraulic conductivity. In general, the results indicate a clear connection between the applied changes in pore characteristics and the SIP response. In particular, we observe a systematic correlation between the hydraulic conductivity and the relaxation time of the Cole-Cole model describing the observed SIP effect for the whole range of considered grain sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibrin glue products and collagen patches are frequently used as a sealing product, preventing surgical side bleedings. This is especially true in the field of cardiovascular surgery, where increasing numbers of patients are being operated with antiplatelet and anticoagulation therapy. The aim of this report was, in an in vitro hemodynamic setting, to examine the sealant properties of the TachoSil (Nycomed Pharma, Linz, Austria) patch. Burst pressure and normal force of 15 TachoSil sealed defects were measured. This was determined in a closed hydraulic system. Mean burst pressure load for a 5-mm defect was 69+/-11.4 mmHg; for a 7-mm defect was 63+/-16 mmHg; and, 62+/-16 mmHg for the defect with a diameter of 10 mm (P>0.05). The mean calculated normal force was as follows: 0.91+/-0.15 N for the 5 mm defect, 6.5+/-1.6 N for the 7 mm, and 8.1+/-0.75 N for the 10 mm defect. The TachoSil patch has the capability to seal small defects. However, at the larger defects the seal character was significantly reduced. These results suggest that the device may be a good alternative for hemostasis for small defects. The capacity to curtail or stop hemorrhage at the larger defects is unlikely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. METHODS: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. RESULTS: There was a good agreement between virtual and real volumes for brain (mean difference: -0.03% (-13.6 to +7.1)), liver (+8.3% (-9.6 to +26.2)) and lungs (+5.5% (-26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). CONCLUSIONS: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nous présontons l'étalonnage d'un test mnésique de recognition dans un échantillon de 180 adultes francophones de la Suisse Romande. Le test comprend trois formes utilisant un matériel verbal (mots) ou non verbal (visages ou paysages). Une attention particulière est accordée à l'âge dans la présentation des résultats. Celui-ci affecte plus précocement et plus intensément la performance aux formes non verbales qu'à la forme verbale du test. Il induit également une importante augmentation du nombre de fausses reconnaissances pour les formes non verbales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Most studies assess the prevalence of hypertension in pediatric populations based on blood pressure (BP) readings taken on a single visit. We determined the prevalence of hypertension measured on up to three visits in a Swiss pediatric population and examined the association between hypertension and overweight and selected other factors. METHODS: Anthropometric data and BP were measured in all children of the sixth school grade of the Vaud canton (Switzerland) in 2005-2006. 'Elevated BP' was defined according to sex-specific, age-specific and height-specific US reference data. BP was measured on up to two additional visits in children with elevated BP. 'Hypertension' was defined as 'elevated BP' on all three visits. RESULTS: Out of 6873 children, 5207 (76%) participated [2621 boys, 2586 girls; mean (SD) age, 12.3 (0.5) years]. The prevalence of elevated BP was 11.4, 3.8 and 2.2% on first, second and thirds visits, respectively; hence 2.2% had hypertension. Among hypertensive children, 81% had isolated systolic hypertension. Hypertension was associated with excess body weight, elevated heart rate and parents' history of hypertension. Of the children, 16.1% of boys and 12.4% of girls were overweight or obese (CDC criteria, body mass index >or= 85th percentile). Thirty-seven percent of cases of hypertension could be attributed to overweight or obesity. CONCLUSIONS: The proportion of children with elevated BP based on one visit was five times higher than based on three measurements taken at few-week intervals. Our data re-emphasize the need for prevention and control of overweight in children to curb the global hypertension burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.