78 resultados para coefficient of nutrient utilization


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glucose exerts inverse effects upon the secretory function of islet alpha- and beta-cells, suppressing glucagon release and increasing insulin release. This diverse action may result from differences in glucose transport and metabolism between the two cell types. The present study compares glucose transport in rat alpha- and beta-cells. beta-Cells transcribed GLUT2 and, to a lesser extent, GLUT 1; alpha-cells contained GLUT1 but no GLUT2 mRNA. No other GLUT-like sequences were found among cDNAs from alpha- or beta-cells. Both cell types expressed 43-kDa GLUT1 protein which was enhanced by culture. The 62-kDa beta-cell GLUT2 protein was converted to a 58-kDa protein after trypsin treatment of the cells without detectable consequences upon glucose transport kinetics. In beta-cells, the rates of glucose transport were 10-fold higher than in alpha-cells. In both cell types, glucose uptake exceeded the rates of glucose utilization by a factor of 10 or more. Glycolytic flux, measured as D-[5(3)H]glucose utilization, was comparable in alpha- and beta-cells between 1 and 10 mmol/liter substrate. In conclusion, differences in glucose transporter gene expression between alpha- and beta-cells can be correlated with differences in glucose transport kinetics but not with different glucose utilization rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various site-specific recombination enzymes produce different types of knots or catenanes while acting on circular DNA in vitro and in vivo. By analysing the types of knots or links produced, it is possible to reconstruct the order of events during the reaction and to deduce the molecular "architecture" of the complexes that different enzymes form with DNA. Until recently it was necessary to use laborious electron microscopy methods to identify the types of knots or catenanes that migrate in different bands on the agarose gels used to analyse the products of the reaction. We reported recently that electrophoretic migration of different knots and catenanes formed on the same size DNA molecules is simply related to the average crossing number of the ideal representations of the corresponding knots and catenanes. Here we explain this relation by demonstrating that the expected sedimentation coefficient of randomly fluctuating knotted or catenated DNA molecules in solution shows approximately linear correlation with the average crossing number of ideal configurations of the corresponding knots or catenanes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single amino acid substitution is the type of protein alteration most related to human diseases. Current studies seek primarily to distinguish neutral mutations from harmful ones. Very few methods offer an explanation of the final prediction result in terms of the probable structural or functional effect on the protein. In this study, we describe the use of three novel parameters to identify experimentally-verified critical residues of the TP53 protein (p53). The first two parameters make use of a surface clustering method to calculate the protein surface area of highly conserved regions or regions with high nonlocal atomic interaction energy (ANOLEA) score. These parameters help identify important functional regions on the surface of a protein. The last parameter involves the use of a new method for pseudobinding free-energy estimation to specifically probe the importance of residue side-chains to the stability of protein fold. A decision tree was designed to optimally combine these three parameters. The result was compared to the functional data stored in the International Agency for Research on Cancer (IARC) TP53 mutation database. The final prediction achieved a prediction accuracy of 70% and a Matthews correlation coefficient of 0.45. It also showed a high specificity of 91.8%. Mutations in the 85 correctly identified important residues represented 81.7% of the total mutations recorded in the database. In addition, the method was able to correctly assign a probable functional or structural role to the residues. Such information could be critical for the interpretation and prediction of the effect of missense mutations, as it not only provided the fundamental explanation of the observed effect, but also helped design the most appropriate laboratory experiment to verify the prediction results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A genome-wide association study (GWAS) of educational attainment was conducted in a discovery sample of 101,069 individuals and a replication sample of 25,490. Three independent single-nucleotide polymorphisms (SNPs) are genome-wide significant (rs9320913, rs11584700, rs4851266), and all three replicate. Estimated effects sizes are small (coefficient of determination R(2) ≈ 0.02%), approximately 1 month of schooling per allele. A linear polygenic score from all measured SNPs accounts for ≈2% of the variance in both educational attainment and cognitive function. Genes in the region of the loci have previously been associated with health, cognitive, and central nervous system phenotypes, and bioinformatics analyses suggest the involvement of the anterior caudate nucleus. These findings provide promising candidate SNPs for follow-up work, and our effect size estimates can anchor power analyses in social-science genetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RÉSUMÉ Les protéines d'ancrage de la protéine kinase A (AKAPs) constituent une grande famille de protéines qui ciblent la protéine kinase A (PKA) à proximité de ses substrats physiologiques pour assurer leur régulation. Une nouvelle protéine de cette famille, appelée AKAP-Lbc, a été récemment caractérisée et fonctionne comme un facteur d'échange de nucléotides guanine (GEF) pour la petite GTPase Rho. AKAP-Lbc est régulée par différents signaux qui activent et désactivent son activité Rho-GEF. Son activation est assurée par la sous-unité alpha de la protéine G hétérotrimérique G12, tandis que son inhibition dépend de son interaction avec la PKA et 14-3-3. AKAP-Lbc est principalement exprimée dans le coeur et pourrait réguler des processus importants tels que l'hypertrophie et la différenciation des cardiomyocytes. Ainsi, il est crucial d'élucider les mécanismes moléculaires impliqués dans la régulation de son activité Rho-GEF. Le but général de ce travail de thèse est la caractérisation de deux nouveaux mécanismes impliqués dans la régulation de l'activité de AKAP-Lbc. Le premier mécanisme consiste en la régulation de l'activité de AKAP-Lbc par son homo-oligomérisation. Mes travaux montrent que l'homo-oligomérisation maintient AKAP-Lbc inactive, dans une conformation permettant à la PKA ancrée et à 14-3-3 d'exercer leur effet inhibiteur sur l'activité de AKAP-Lbc. Le second mécanisme concerne la régulation de l'activité de AKAP-Lbc via une nouvelle interaction entre AKAP-Lbc et la protéine LC3. LC3 joue un rôle crucial dans l'autophagie, un processus cellulaire qui adresse les protéines cytoplasmiques au lysosome pour leur dégradation. Ce mécanisme est particulièrement important pour le survie des cardiomyocytes durant les périodes d'absence de nutriments. Mes travaux mettent en évidence que LC3 inhibe l'activité Rho-GEF de AKAP-Lbc, ce qui suggère que, au-delà son rôle bien établi dans l'autophagie, LC3 participerait à la régulation de la signalisation de Rho. Prises ensembles, ces études contribuent à comprendre comment le complexe de signalisation formé par AKAP-Lbc régule la signalisation de Rho dans les cellules. Au-delà de leur intérêt au niveau biochimique, ces travaux pourraient aussi contribuer à élucider les réseaux de signalisation qui régulent des phénomènes physiologiques dans le coeur. ABSTRACT A-kinase anchoring proteins (AKAPs) are a group of functionally related proteins, which target the cAMP dependent protein kinase A (PKA) in close proximity to its physiological substrates for ensuring their regulation. A novel PKA anchoring protein, termed AKAP-Lbc, has been recently characterized, which also functions as a guanine nucleotide exchange factor (GEF) for the small GTPase Rho. AKAP-Lbc is regulated in a bi-directional manner by signals which activate or deactivate its Rho-GEF activity. Activation is mediated by the alpha subunit of the heterotrimeric G protein G12, whereas inhibition occurs following its interaction with PKA and 14-3-3. AKAP-Lbc is predominantly expressed in the heart and might regulate important processes such as hypertrophy and differentiation of cardiomyocytes. Therefore ít is crucial to elucidate the molecular mechanisms involved in the regulation of the Rho-GEF activity of AKAP-Lbc. The general aim of the present thesis work is the characterization of two novel molecular mechanisms involved in the regulation of the Rho-GEF activity of AKAP-Lbc. The first mechanism consists of the. regulation of AKAP-Lbc activity through its homooligomerization. I report here that homo-oligomerization maintains AKAP-Lbc inactive, under a conformation suitable for ensuring the inhibitory effect of anchored PKA and 14-33 on AKAP-Lbc activity. The second mechanism concerns the regulation of AKAP-Lbc activity through a novel interaction between AKAP-Lbc and ubiquitin-like protein LC3. LC3 is a key mediator of autophagy, which is a cellular process that targets cytosolic proteins to the lysosome for degradation. This process is particularly important for cardiomyocyte survival during conditions of nutrient starvation. Here, I show that LC3 is a negative regulator of the Rho-GEF activity of AKAP-Lbc, which suggests that, beyond its well established role in autophagy, LC3 can participate in the regulation of Rho signaling in cells. Overall, these findings contribute to understand how the AKAP-Lbc signaling complex can regulate the Rho signaling in cells. Beyond its interest at the biochemical level, this work might also contribute to elucidate the signaling network that regulate physiological events in the heart.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM) was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1 mm high-resolution maps of the longitudinal relaxation rate (R1 = 1/T1), effective proton density (PD(*)), magnetization transfer saturation (MT) and effective transverse relaxation rate (R2(*) = 1/T2(*)). MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV) for typical morphometric measures [i.e., gray matter (GM) probability maps used in voxel-based morphometry] and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1 and 8%, respectively, except for the inter-site CoV of R2(*) (<20%). The GM probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived GM probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Permian Chert Event (PCE) was a 30 Ma long episode of unusual chert accumulation along the northwest margin of Pangea, and possibly worldwide. The onset of the PCE occurred at about the Sakmarian-Artinskian boundary in the Sverdrup Basin, Canadian Arctic, where it coincides with a maximum flooding event, the ending of high-frequency/high-amplitude shelf cyclicity, the onset of massive biogenic chert deposition in deep-water distal areas, and a long-term shift from warm- to cool-water carbonate sedimentation in shallow-water proximal areas. A similar and coeval shift is observed from the Barents Sea to the northwestern USA. A landward and southward expansion of silica factories occurred during the Middle and Late Permian at which time warm-water carbonate producers disappeared completely from the northwest margin of Pangea. Biotically impoverished and increasingly narrow cold-water carbonate factories (characterised by non-cemented bioclasts of sponges, bryozoans, echinoderms and brachiopods) were then progressively replaced by silica factories. By Late Permian time, little carbonate sediments accumulated in the Barents Sea and in the Sverdrup Basin. where the deep- to shallow-water sedimentary spectrum was occupied by siliceous sponge spicules. By that time, biogenic silica sedimentation was common throughout the world. Silica factories collapsed in the Late Permian, abruptly bringing the PCE to an end. In northwest Pangea, the end- Permian collapse of the PCE was associated with a major transgression and with a return to much warmer oceanic and continental climatic conditions. Chert deposition resumed in the distal oceanic areas during the early Middle Triassic (Anisian) after a 8-10 Ma interruption (Early Triassic Chert Gap). The conditions necessary for the onset, expansion and zenith of the PCE were provided by the thermohaline circulation of nutrient-rich cold waters along the northwestern and western margin of Pangea, and possibly throughout the world oceans. These conditions provided an efficient transportation mechanism that constantly replenished the supply of silica in the area, created a nutrient- and oxygen-rich environment favouring siliceous biogenic productivity. established cold sea-floor conditions, hindering silica dissolution, while increasing calcium carbonate solubility, and provided conditions adverse to organic and inorganic carbonate production, The northwest margin of Pangea was, for nearly 30 Ma. bathed by cold waters presumably derived from the seasonal melting of northern sea ice, the assumed engine for thermohaline circulation. This process started near the Sakmarian-Artinskian boundary. intensified throughout Middle and Late Permian time and ceased suddenly in latest Permian time, It led to oceanic conditions much colder than normally expected from the palaeolatitudes. and the influence of cold northerly-derived water was felt as far south southern Nevada. The demise of silica factories was caused by the rapid breakdown of these conditions and the establishment of a much warmer marine environment accompanied by sluggish circulation and perhaps a reduced input of dissolved silica to the ocean. Complete thawing of northern sea ice would have ended thermohaline circulation and led to warm and sluggish oceanic conditions inimical to the production. accumulation and preservation of biogenic silica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.