78 resultados para Solvent replacement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Key factors of Fast Track (FT) programs are fluid restriction and epidural analgesia (EDA). We aimed to challenge the preconception that the combination of fluid restriction and EDA might induce hypotension and renal dysfunction. METHODS: A recent randomized trial (NCT00556790) showed reduced complications after colectomy in FT patients compared with standard care (SC). Patients with an effective EDA were compared with regard to hemodynamics and renal function. RESULTS: 61/76 FT patients and 59/75 patients in the SC group had an effective EDA. Both groups were comparable regarding demographics and surgery-related characteristics. FT patients received significantly less i.v. fluids intraoperatively (1900 mL [range 1100-4100] versus 2900 mL [1600-5900], P < 0.0001) and postoperatively (700 mL [400-1500] versus 2300 mL [1800-3800], P < 0.0001). Intraoperatively, 30 FT compared with 19 SC patients needed colloids or vasopressors, but this was statistically not significant (P = 0.066). Postoperative requirements were low in both groups (3 versus 5 patients; P = 0.487). Pre- and postoperative values for creatinine, hematocrit, sodium, and potassium were similar, and no patient developed renal dysfunction in either group. Only one of 82 patients having an EDA without a bladder catheter had urinary retention. Overall, FT patients had fewer postoperative complications (6 versus 20 patients; P = 0.002) and a shorter median hospital stay (5 [2-30] versus 9 d [6-30]; P< 0.0001) compared with the SC group. CONCLUSIONS: Fluid restriction and EDA in FT programs are not associated with clinically relevant hemodynamic instability or renal dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The last decade has seen a proliferation in options for testosterone replacement. However, little is known as to the benefits of different treatment modalities. Our objective was to determine the testosterone prescription pattern and to examine the impact on various outcome measures. SUBJECTS AND METHODS: A total of 816 adult-onset hypopituitary males on stable pituitary replacement for at least 1 year were identified from the KIMS database. Patients were classified as either eugonadal (n = 106), or hypogonadal (n = 710) on intramuscular (IM, n = 558), oral (n = 74), transdermal (n = 61), and depot (n = 17) testosterone. RESULTS: After 1 year of stable pituitary replacement therapy, body composition, cardiovascular parameters, GH replacement and quality of life were not significantly different in androgen-replaced hypogonadal patients compared to eugonadal patients. There were no differences in outcome variables within the hypogonadal group according to the testosterone replacement regimen used and no difference in response to GH therapy. CONCLUSIONS: The majority of hypopituitary patients in the last decade have received IM testosterone. Body composition, cardiovascular parameters, GH replacement and quality of life were not different between eugonadal and hypogonadal patients and were not differentially affected by the mode of testosterone replacement. These findings are reassuring that there is no major difference in response to different testosterone replacement regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Valanginian is marked by a major platform demise inducing a hiatus in the northern Tethyan neritic carbonate record from the top of the lower Valanginian to the lower Hauterivian. New biostratigraphic and chemostratigraphic data from the Ollioules section (Provence Platform, southern France) are presented here, demonstrating that a large part of the upper Valanginian is preserved in an inner platform environment. The thick, upper Valanginian, aggrading carbonate succession is observed in an aborted rift domain, implying relatively low subsidence. In this context, a relatively long-term sea-level rise was required to sustain a keep-up style of carbonate production. Like the Apulian Platform, the remarkable preservation of the Provence Platform may have been favored by its remoteness from terrigenous source areas, as suggested by the low clastic inputs and low P-accumulation rates. Two main biotic community replacements are observed in Ollioules. The first saw the development of abundant microbialites and algae at the onset of the late Valanginian. A Tubiphytes concentration occurred during the coolest climatic conditions and the transition towards arid conditions, whereas the subsequent Lithocodium-Bacinella and orbitolinids assemblages developed under low nutrient conditions during a warmer interval. Both assemblages may have been triggered by increased alkalinity. The second community replacement saw the installation of coral- and rudist-dominated communities during the latest Valanginian to early Hauterivian. They indicate a change to oligotrophic, open marine conditions. Six medium-scale sequences have been defined in Ollioules, indicating short-term transgressive-regressive trends superimposed on a long-term transgression. Low nutrient inputs and relatively low subsidence in an aggradational context may explain the survival of the isolated Provence Carbonate Platform during a time of widespread drowning episodes and platform demise in the northern Tethyan domain. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine whether valganciclovir 450 mg every 48 h for cytomegalovirus (CMV) prophylaxis provides appropriate ganciclovir exposure in solid organ transplant recipients during continuous renal replacement therapy (CRRT). PATIENTS AND METHODS: Ganciclovir pharmacokinetics was intensively studied in two lung transplant recipients under valganciclovir 450 mg every 48 h over one dosing interval. In vitro experiments using blank whole blood spiked with ganciclovir further investigated exchanges between plasma and erythrocytes. RESULTS: Ganciclovir disposition was characterized by apparent total body clearance of 3.3 and 5.8 L/h, terminal half-life of 16.9 and 14.1 h, and apparent volume of distribution of 60.3 and 104.9 L in Patients 1 and 2, respectively. The observed sieving coefficient was 1.05 and 0.96, and the haemofiltration clearance was 3.3 and 3.1 L/h. In vitro experiments confirmed rapid efflux of ganciclovir from red blood cells into plasma, increasing the apparent efficacy of haemofiltration. CONCLUSIONS: A valganciclovir dosage of 450 mg every 48 h appears adequate for patients under CRRT requiring prophylaxis for CMV infection, providing concentration levels in the range reported for 900 mg once daily dosing outside renal failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies assessed the outcome of ankle arthrodesis (AA) and total ankle replacement (TAR) surgeries; however, the extent of postoperative recovery towards bilateral gait mechanics (BGM) is unknown. We evaluated the outcome of the two surgeries at least 2 years post rehabilitation, focusing on BGM. 36 participants, including 12 AA patients, 12 TAR patients, and 12 controls were included. Gait assessment over 50 m distance was performed utilizing pressure insoles and 3D inertial sensors, following which an intraindividual comparison was performed. Most spatiotemporal and kinematic parameters in the TAR group were indicative of good gait symmetry, while the AA group presented significant differences. Plantar pressure symmetry among the AA group was also significantly distorted. Abnormality in biomechanical behavior of the AA unoperated, contralateral foot was observed. In summary, our results indicate an altered BGM in AA patients, whereas a relatively fully recovered BGM is observed in TAR patients, despite the quantitative differences in several parameters when compared to a healthy population. Our study supports a biomechanical assessment and rehabilitation of both operated and unoperated sides after major surgeries for ankle osteoarthrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). METHODS: We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. RESULTS: The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. CONCLUSION: Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.