127 resultados para Measuring parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Colonoscopy is generally performed with the patient sedated and receiving analgesics. However, the benefit of the most often used combination of intravenous midazolam and pethidine on patient tolerance and pain and its cardiorespiratory risk have not been fully defined. METHODS: In this double-blind prospective study, 150 outpatients undergoing routine colonoscopy were randomly assigned to receive either (1) low-dose midazolam (35 micrograms/kg) and pethidine (700 micrograms/kg in 48 patients, 500 micrograms/kg in 102 patients), (2) midazolam and placebo pethidine, or (3) pethidine and placebo midazolam. RESULTS: Tolerance (visual analog scale, 0 to 100 points: 0 = excellent; 100 = unbearable) did not improve significantly more in group 1 compared with group 2 (7 points; 95% confidence interval [-2-17]) and group 3 (2 points; 95% confidence interval [-7-12]). Similarly, pain was not significantly improved in group 1 as compared with the other groups. Male gender (p < 0.001) and shorter duration of the procedure (p = 0.004), but not amnesia, were associated with better patient tolerance and less pain. Patient satisfaction was similar in all groups. Oxygen desaturation and hypotension occurred in 33% and 11%, respectively, with a similar frequency in all three groups. CONCLUSIONS: In this study, the combination of low-dose midazolam and pethidine does not improve patient tolerance and lessen pain during colonoscopy as compared with either drug given alone. When applying low-dose midazolam, oxygen desaturation and hypotension do not occur more often after combined use of both drugs. For the individual patient, sedation and analgesia should be based on the endoscopist's clinical judgement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the power of various parameters of the vestibulo-ocular reflex (VOR) in detecting unilateral peripheral vestibular dysfunction and in characterizing certain inner ear pathologies. STUDY DESIGN: Prospective study of consecutive ambulatory patients presenting with acute onset of peripheral vertigo and spontaneous nystagmus. SETTING: Tertiary referral center. PATIENTS: Seventy-four patients (40 females, 34 males) and 22 normal subjects (11 females, 11 males) were included in the study. Patients were classified in three main diagnoses: vestibular neuritis: 40; viral labyrinthitis: 22; Meniere's disease: 12. METHODS: The VOR function was evaluated by standard caloric and impulse rotary tests (velocity step). A mathematical model of vestibular function was used to characterize the VOR response to rotational stimulation. The diagnostic value of the different VOR parameters was assessed by uni- and multivariable logistic regression. RESULTS: In univariable analysis, caloric asymmetry emerged as the most powerful VOR parameter in identifying unilateral vestibular deficit, with a boundary limit set at 20%. In multivariable analysis, the combination of caloric asymmetry and rotational time constant asymmetry significantly improved the discriminatory power over caloric alone (p&lt;0.0001) and produced a detection score with a correct classification of 92.4%. In discriminating labyrinthine diseases, different combinations of the VOR parameters were obtained for each diagnosis (p&lt;0.003) supporting that the VOR characteristics differ between the three inner ear disorders. However, the clinical usefulness of these characteristics in separating the pathologies was limited. CONCLUSION: We propose a powerful logistic model combining the indices of caloric and time constant asymmetries to detect a peripheral vestibular loss, with an accuracy of 92.4%. Based on vestibular data only, the discrimination between the different inner ear diseases is statistically possible, which supports different pathophysiologic changes in labyrinthine pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performing a complete blood count analysis is a daily routine necessary for a good care of patients. Nowadays, modern blood analyzers provide on top of classical blood values, several additional parameters. In this paper, using short case presentations, we discuss how to interpret these results and integrate them in the clinical context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe a method to obtain a profile of the duration and intensity (speed) of walking periods over 24 hours in women under free-living conditions. DESIGN: A new method based on accelerometry was designed for analyzing walking activity. In order to take into account inter-individual variability of acceleration, an individual calibration process was used. Different experiments were performed to highlight the variability of acceleration vs walking speed relationship, to analyze the speed prediction accuracy of the method, and to test the assessment of walking distance and duration over 24-h. SUBJECTS: Twenty-eight women were studied (mean+/-s.d.) age: 39.3+/-8.9 y; body mass: 79.7+/-11.1 kg; body height: 162.9+/-5.4 cm; and body mass index (BMI) 30.0+/-3.8 kg/m(2). RESULTS: Accelerometer output was significantly correlated with speed during treadmill walking (r=0.95, P<0.01), and short unconstrained walks (r=0.86, P<0.01), although with a large inter-individual variation of the regression parameters. By using individual calibration, it was possible to predict walking speed on a standard urban circuit (predicted vs measured r=0.93, P<0.01, s.e.e.=0.51 km/h). In the free-living experiment, women spent on average 79.9+/-36.0 (range: 31.7-168.2) min/day in displacement activities, from which discontinuous short walking activities represented about 2/3 and continuous ones 1/3. Total walking distance averaged 2.1+/-1.2 (range: 0.4-4.7) km/day. It was performed at an average speed of 5.0+/-0.5 (range: 4.1-6.0) km/h. CONCLUSION: An accelerometer measuring the anteroposterior acceleration of the body can estimate walking speed together with the pattern, intensity and duration of daily walking activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-noise ratio (SNR) and vessel sharpness were compared. It was found that for improved mage quality a short navigator evaluation time is of crucial importance. Navigator spatial resolution showed minimal influence on image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary : International comparisons in the area of victimization, particularly in the field of violence against women, are fraught with methodological problems that previous research has not systematically addressed, and whose answer does not seem to be agreed up~n. For obvious logistic and financial reasons, international studies on violence against women (i.e. studies that administer the same instrument in different countries). are seldom; therefore, researchers are bound to resort to secondary comparisons. Many studies simply juxtapose their results to the ones of previous wòrk or to findings obtained in different contexts, in order to offer an allegedly comparative perspective to their conclusions. If, most of the time, researchers indicate the methodological limitations of a direct comparison, it is not rare that these do not result in concrete methodological controls. Yet, many studies have shown the influence of surveys methodological parameters on findings, listing recommendations fora «best practice» of research. Although, over the past decades, violence against women surveys have become more and more similar -tending towards a sort of uniformization that could be interpreted as a passive consensus -these instruments retain more or less subtle differences that are still susceptible to influence the validity of a comparison. Yet, only a small number of studies have directly worked on the comparability of violence against women data, striving to control the methodological parameters of the surveys in order to guarantee the validity of their comparisons. The goal of this work is to compare data from two national surveys on violence against women: the Swiss component of the International Violence Against Women Survey [CH-IVAWS] and the National Violence Against Women Survey [NVAWS] administered in the United States. The choice of these studies certainly ensues from the author's affiliations; however, it is far from being trivial. Indeed, the criminological field currently endows American and Anglo-Saxon literature with a predominant space, compelling researchers from other countries to almost do the splits to interpret their results in the light of previous work or to develop effective interventions in their own context. Turning to hypotheses or concepts developed in a specific framework inevitably raises the issue of their applicability to another context, i.e. the Swiss context, if not at least European. This problematic then takes on an interest that goes beyond the particular topic of violence against women, adding to its relevance. This work articulates around three axes. First, it shows the way survey characteristics influence estimates. The comparability of the nature of the CH-IVAWS and NVAWS, their sampling design and the characteristics of their administration are discussed. The definitions used, the operationalization of variables based on comparable items, the control of reference periods, as well as the nature of the victim-offender relationship are included among controlled factors. This study establishes content validity within and across studies, presenting a systematic process destined to maximize the comparability of secondary data. Implications of the process are illustrated with the successive presentation of comparable and non-comparable operationalizations of computed variables. Measuring violence against. women in Switzerland and the United-States, this work compares the prevalence of different forms (threats, physical violence and sexual violence) and types of violence (partner and nonpartner violence). Second, it endeavors to analyze concepts of multivictimization (i.e. experiencing different forms of victimization), repeat victimization (i.e. experiencing the same form of violence more than once), and revictimization (i.e. the link between childhood and adulthood victimization) in a comparative -and comparable -approach. Third, aiming at understanding why partner violence appears higher in the United States, while victims of nonpartners are more frequent in Switzerland, as well as in other European countries, different victimization correlates are examined. This research contributes to a better understanding of the relevance of controlling methodological parameters in comparisons across studies, as it illustrates, systematically, the imposed controls and their implications on quantitative data. Moreover, it details how ignoring these parameters might lead to erroneous conclusions, statistically as well as theoretically. The conclusion of the study puts into a wider perspective the discussion of differences and similarities of violence against women in Switzerland and the United States, and integrates recommendations as to the relevance and validity of international comparisons, whatever the'field they are conducted in. Résumé: Les comparaisons internationales dans le domaine de la victimisation, et plus particulièrement en ce qui concerne les violences envers les femmes, se caractérisent par des problèmes méthodologiques que les recherches antérieures n'ont pas systématiquement adressés, et dont la réponse ne semble pas connaître de consensus. Pour des raisons logistiques et financières évidentes, les études internationales sur les violences envers les femmes (c.-à-d. les études utilisant un même instrument dans différents pays) sont rares, aussi les chercheurs sont-ils contraints de se tourner vers des comparaisons secondaires. Beaucoup de recherches juxtaposent alors simplement leurs résultats à ceux de travaux antérieurs ou à des résultats obtenus dans d'autres contextes, afin d'offrir à leurs conclusions une perspective prétendument comparative. Si, le plus souvent, les auteurs indiquent les limites méthodologiques d'une comparaison directe, il est fréquent que ces dernières ne se traduisent pas par des contrôles méthodologiques concrets. Et pourtant, quantité de travaux ont mis en évidence l'influence des paramètres méthodologiques des enquêtes sur les résultats obtenus, érigeant des listes de recommandations pour une «meilleure pratique» de la recherche. Bien que, ces dernières décennies, les sondages sur les violences envers les femmes soient devenus de plus en plus similaires -tendant, vers une certaine uniformisation que l'on peut interpréter comme un consensus passif-, il n'en demeure pas moins que ces instruments possèdent des différences plus ou moins subtiles, mais toujours susceptibles d'influencer la validité d'une comparaison. Pourtant, seules quelques recherches ont directement travaillé sur la comparabilité des données sur les violences envers les femmes, ayant à coeur de contrôler les paramètres méthodologiques des études utilisées afin de garantir la validité de leurs comparaisons. L'objectif de ce travail est la comparaison des données de deux sondages nationaux sur les violences envers les femmes: le composant suisse de l'International Violence Against Women Survey [CHIVAWSj et le National Violence Against Women Survey [NVAWS) administré aux États-Unis. Le choix de ces deux études découle certes des affiliations de l'auteure, cependant il est loin d'être anodin. Le champ criminologique actuel confère, en effet, une place prépondérante à la littérature américaine et anglo-saxonne, contraignant ainsi les chercheurs d'autres pays à un exercice proche du grand écart pour interpréter leurs résultats à la lumière des travaux antérieurs ou développer des interventions efficaces dans leur propre contexte. Le fait de recourir à des hypothèses et des concepts développés dans un cadre spécifique pose inévitablement la question de leur applicabilité à un autre contexte, soit ici le contexte suisse, sinon du moins européen. Cette problématique revêt alors un intérêt qui dépasse la thématique spécifique des violences envers les femmes, ce qui ajoute à sa pertinence. Ce travail s'articule autour de trois axes. Premièrement, il met en évidence la manière dont les caractéristiques d'un sondage influencent les estimations qui en découlent. La comparabilité de la nature du CH-IVAWS et du NVAWS, de leur processus d'échantillonnage et des caractéristiques de leur administration est discutée. Les définitions utilisées, l'opérationnalisation des variables sur la base d'items comparables, le contrôle des périodes de référence, ainsi que la nature de la relation victime-auteur figurent également parmi les facteurs contrôlés. Ce travail établit ainsi la validité de contenu intra- et inter-études, offrant un processus systématique destiné à maximiser la comparabilité des données secondaires. Les implications de cette démarche sont illustrées avec la présentation successive d'opérationnalisations comparables et non-comparables des variables construites. Mesurant les violences envers les femmes en Suisse et aux États-Unis, ce travail compare la prévalence de plusieurs formes (menaces, violences physiques et violences sexuelles) et types de violence (violences partenaires et non-partenaires). 11 s'attache également à analyser les concepts de multivictimisation (c.-à-d. le fait de subir plusieurs formes de victimisation), victimisation répétée (c.-à.-d. le fait de subir plusieurs incidents de même forme) et revictimisation (c.-à-d. le lien entre la victimisation dans l'enfance et à l'âge adulte) dans une approche comparative - et comparable. Dans un troisième temps, cherchant à comprendre pourquoi la violence des partenaires apparaît plus fréquente aux États-Unis, tandis que les victimes de non-partenaires sont plus nombreuses en Suisse, et dans d'autres pays européens, différents facteurs associés à la victimisation sont évalués. Cette recherche participe d'une meilleure compréhension de la pertinence du contrôle des paramètres méthodologiques dans les comparaisons entre études puisqu'elle illustre, pas à pas, les contrôles imposés et leurs effets sur les données quantitatives, et surtout comment l'ignorance de ces paramètres peut conduire à des conclusions erronées, tant statistiquement que théoriquement. La conclusion replace, dans un contexte plus large, la discussion des différences et des similitudes observées quant à la prévalence des violences envers les femmes en Suisse et aux États-Unis, et intègre des recommandations quant à la pertinence et à la validité des comparaisons internationales, cela quel que soit le domaine considéré.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.