133 resultados para ANGIOTENSIN-(1-12)
Resumo:
OBJECTIVES: We examined the social distribution of a comprehensive range of cardiovascular risk factors (CVRF) in a Swiss population and assessed whether socioeconomic differences varied by age and gender. METHODS: Participants were 2960 men and 3343 women aged 35-75 years from a population-based survey conducted in Lausanne, Switzerland (CoLaus study). Educational level was the indicator of socioeconomic status used in this study. Analyses were stratified by gender and age group (35-54 years; 55-75 years). RESULTS: There were large educational differences in the prevalence of CVRF such as current smoking (Δ = absolute difference in prevalence between highest and lowest educational group:15.1%/12.6% in men/women aged 35-54 years), physical inactivity (Δ = 25.3%/22.7% in men/women aged 35-54 years), overweight and obesity (Δ = 14.6%/14.8% in men/women aged 55-75 years for obesity), hypertension (Δ = 16.7%/11.4% in men/women aged 55-75 years), dyslipidemia (Δ = 2.8%/6.2% in men/women aged 35-54 years for high LDL-cholesterol) and diabetes (Δ = 6.0%/2.6% in men/women aged 55-75 years). Educational inequalities in the distribution of CVRF were larger in women than in men for alcohol consumption, obesity, hypertension and dyslipidemia (p<0.05). Relative educational inequalities in CVRF tended to be greater among the younger (35-54 years) than among the older age group (55-75 years), particularly for behavioral CVRF and abdominal obesity among men and for physiological CVRF among women (p<0.05). CONCLUSION: Large absolute differences in the prevalence of CVRF according to education categories were observed in this Swiss population. The socioeconomic gradient in CVRF tended to be larger in women and in younger persons.
Resumo:
Mutations of the TP53 and Ki-ras genes have been reported to be of prognostic importance in colorectal carcinomas. An increased intracellular concentration of the p53 protein, although not identical to, is sometimes seen in tumours with TP53 mutation and has been correlated with poor prognosis in some tumour types. Previous colorectal cancer studies, addressing the prognostic importance of Ki-ras mutation and TP53 aberrations, yielded contradictory results. The aim of this study was to determine in a clinically and therapeutically homogeneous group of 122 sporadic Dukes' B colorectal carcinomas with a median follow-up of 67 months (3-144 months) whether or not p53 protein expression, TP53 mutation and K-ras mutation correlated with prognosis. p53 staining was performed by immunohistochemistry, using the monoclonal antibody DO7 on paraffin-embedded tissue. Mutations in exons 5-8 of the TP53 gene and in codons 12 and 13 of the K-ras gene were assayed in paraffin-embedded tissue by the single-strand conformation polymorphism (SSCP) assay. Nuclear p53 staining was found in 57 (47%) tumours. Aberrant migration patterns indicating mutation of the TP53 gene were found in 39 (32%) tumours. Forty-six carcinomas (38%) showed a mutation of the Ki-ras codons 12 or 13. In a univariate analysis, patients with wild-type TP53 status showed a trend towards better survival, compared with those with mutated TP53 (log-rank test, P = 0.051). Likewise, tumours immunohistochemically positive for p53 showed a worse prognosis than p53-negative tumours (P = 0.010). The presence or absence of mutations in Ki-ras did not correlate with prognosis (P = 0.703). In multivariate analysis, only p53 immunoreactivity emerged as an independent marker for prognosis hazard ratio (HR) = 2.16, 95% confidence interval (CI) 1.12-4.11, P = 0.02). Assessment of p53 protein expression is more discriminative than TP53 mutation to predict the outcome of Dukes' stage B tumours and could be a useful tool to identify patients who might benefit from adjuvant therapy.
Resumo:
OBJECTIVE: This study aimed to assess the impact of individual comorbid conditions as well as the weight assignment, predictive properties and discriminating power of the Charlson Comorbidity Index (CCI) on outcome in patients with acute coronary syndrome (ACS). METHODS: A prospective multicentre observational study (AMIS Plus Registry) from 69 Swiss hospitals with 29 620 ACS patients enrolled from 2002 to 2012. The main outcome measures were in-hospital and 1-year follow-up mortality. RESULTS: Of the patients, 27% were female (age 72.1 ± 12.6 years) and 73% were male (64.2 ± 12.9 years). 46.8% had comorbidities and they were less likely to receive guideline-recommended drug therapy and reperfusion. Heart failure (adjusted OR 1.88; 95% CI 1.57 to 2.25), metastatic tumours (OR 2.25; 95% CI 1.60 to 3.19), renal diseases (OR 1.84; 95% CI 1.60 to 2.11) and diabetes (OR 1.35; 95% CI 1.19 to 1.54) were strong predictors of in-hospital mortality. In this population, CCI weighted the history of prior myocardial infarction higher (1 instead of -0.4, 95% CI -1.2 to 0.3 points) but heart failure (1 instead of 3.7, 95% CI 2.6 to 4.7) and renal disease (2 instead of 3.5, 95% CI 2.7 to 4.4) lower than the benchmark, where all comorbidities, age and gender were used as predictors. However, the model with CCI and age has an identical discrimination to this benchmark (areas under the receiver operating characteristic curves were both 0.76). CONCLUSIONS: Comorbidities greatly influenced clinical presentation, therapies received and the outcome of patients admitted with ACS. Heart failure, diabetes, renal disease or metastatic tumours had a major impact on mortality. CCI seems to be an appropriate prognostic indicator for in-hospital and 1-year outcomes in ACS patients. ClinicalTrials.gov Identifier: NCT01305785.
Resumo:
Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.
Resumo:
BACKGROUND: Hyperhomocysteinaemia has been identified as an independent cardiovascular risk factor and is found in more than 85% of patients on maintenance haemodialysis. Previous studies have shown that folic acid can lower circulating homocysteine in dialysis patients. We evaluated prospectively the effect of increasing the folic acid dosage from 1 to 6 mg per dialysis on plasma total homocysteine levels of haemodialysis patients with and without a history of occlusive vascular artery disease (OVD). METHODS: Thirty-nine stable patients on high-flux dialysis were studied. Their mean age was 63 +/-11 years and 17 (43%) had a history of OVD, either coronary and/or cerebral and/or peripheral occlusive disease. For several years prior to the study, the patients had received an oral post-dialysis multivitamin supplement including 1 mg of folic acid per dialysis. After baseline determinations, the folic acid dose was increased from 1 to 6 mg/dialysis for 3 months. RESULTS: After 3 months, plasma homocysteine had decreased significantly by approximately 23% from 31.1 +/- 12.7 to 24.5 +/- 9 micromol/l (P = 0.0005), while folic acid concentrations had increased from 6.5 +/- 2.5 to 14.4+/-2.5 microg/l (P < 0.0001). However, the decrease of homocysteine was quite different in patients with and in those without OVD. In patients with OVD, homocysteine decreased only marginally by approximately 2.5% (from 29.0 +/- 10.3 to 28.3 +/- 8.4 micromol/l, P = 0.74), whereas in patients without OVD there was a significant reduction of approximately 34% (from 32.7+/-14.4 to 21.6+/-8.6 micromol/l, P = 0.0008). Plasma homocysteine levels were reduced by > 15% in three patients (18%) in the group with OVD compared with 19 (86%) in the group without OVD (P = 0.001), and by > 30% in none of the patients (0%) in the former group compared with 13 (59%) in the latter (P = 0.001). CONCLUSIONS: These results indicate that the homocysteine-lowering effect of folic acid administration appears to be less effective in haemodialysis patients having occlusive vascular disease than in those without evidence of such disease.
Resumo:
One of the key challenges in the field of nanoparticle (NP) analysis is in producing reliable and reproducible characterisation data for nanomaterials. This study looks at the reproducibility using a relatively new, but rapidly adopted, technique, Nanoparticle Tracking Analysis (NTA) on a range of particle sizes and materials in several different media. It describes the protocol development and presents both the data and analysis of results obtained from 12 laboratories, mostly based in Europe, who are primarily QualityNano members. QualityNano is an EU FP7 funded Research Infrastructure that integrates 28 European analytical and experimental facilities in nanotechnology, medicine and natural sciences with the goal of developing and implementing best practice and quality in all aspects of nanosafety assessment. This study looks at both the development of the protocol and how this leads to highly reproducible results amongst participants. In this study, the parameter being measured is the modal particle size.
Resumo:
A high heart rate (HR) predicts future cardiovascular events. We explored the predictive value of HR in patients with high-risk hypertension and examined whether blood pressure reduction modifies this association. The participants were 15,193 patients with hypertension enrolled in the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial and followed up for 5 years. The HR was assessed from electrocardiographic recordings obtained annually throughout the study period. The primary end point was the interval to cardiac events. After adjustment for confounders, the hazard ratio of the composite cardiac primary end point for a 10-beats/min of the baseline HR increment was 1.16 (95% confidence interval 1.12 to 1.20). Compared to the lowest HR quintile, the adjusted hazard ratio in the highest quintile was 1.73 (95% confidence interval 1.46 to 2.04). Compared to the pooled lower quintiles of baseline HR, the annual incidence of primary end point in the top baseline quintile was greater in each of the 5 study years (all p <0.05). The adjusted hazard ratio for the primary end point in the highest in-trial HR heart rate quintile versus the lowest quintile was 1.53 (95% confidence interval 1.26 to 1.85). The incidence of primary end points in the highest in-trial HR group compared to the pooled 4 lower quintiles was 53% greater in patients with well-controlled blood pressure (p <0.001) and 34% greater in those with uncontrolled blood pressure (p = 0.002). In conclusion, an increased HR is a long-term predictor of cardiovascular events in patients with high-risk hypertension. This effect was not modified by good blood pressure control. It is not yet known whether a therapeutic reduction of HR would improve cardiovascular prognosis.
Resumo:
The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS: Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS: CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P <or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P < 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P <or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION: The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.
Resumo:
The progression of liver fibrosis in chronic hepatitis C has long been considered to be independent from viral genotypes. However, recent studies suggest an association between Hepatitis C virus (HCV) genotype 3 and accelerated liver disease progression. We completed a systematic review and meta-analysis of studies evaluating the association between HCV genotypes and fibrosis progression. PubMed, Embase and ISI Web of Knowledge databases were searched for cohort, cross-sectional and case-control studies on treatment-naïve HCV-infected adults in which liver fibrosis progression rate (FPR) was assessed by the ratio of fibrosis stage in one single biopsy to the duration of infection (single-biopsy studies) or from the change in fibrosis stage between two biopsies (paired biopsies studies). A random effect model was used to derive FPR among different HCV genotypes. Eight single-biopsy studies (3182 patients, mean/median duration of infection ranging from 9 to 21 years) and eight paired biopsies studies (mean interval between biopsies 2-12 years) met the selection criteria. The odds ratio for the association of genotype 3 with accelerated fibrosis progression was 1.52 (95% CI 1.12-2.07, P = 0.007) in single-biopsy studies and 1.37 (95% CI 0.87-2.17, P = 0.17) in paired biopsy studies. In conclusion, viral genotype 3 was associated with faster fibrosis progression in single-biopsy studies. This observation may have important consequences on the clinical management of genotype 3-infected patients. The association was not significant in paired biopsies studies, although the latter may be limited by important indication bias, short observation time and small sample size.
Resumo:
Background: Publications from the International Breast Screening Network (IBSN) have shown that varying definitions create hurdles for comparison of screening performance. Interval breast cancer rates are particularly affected. Objective: to test whether variations in definition of interval cancer rates (ICR) affect comparisons of international ICR, specific to a comparison of ICR in Norway and North Carolina (NC). Methods: An interval cancer (IC) was defined as a cancer diagnosed following a negative screening mammogram in a defined follow-up period. ICR was calculated for women ages 50-69, at subsequent screening in Norway and NC, during the time period 1996 - 2002. ICR was defined using three different denominators (negative screens, negative final assessments and all screens) and three different numerators (DCIS, invasive cancer and all cancers). ICR was then calculated with two methods: 1) number of ICs divided by the number of screens, and ICs divided by the number of women-years at risk for IC. Results: There were no differences in ICR depending on the definition used. In the 1-12 month follow up period ICR (based on number of screens) were: 0.53, 0.54, and 0.54 for Norway; and 1.20, 1.25 and 1.17 for NC, for negative screens, negative final assessment and all screens, respectively: The same trend was seen for 13-24 and 1-24 months follow-up. Using women-years for the analysis did not change the trend. ICR was higher in NC compared to Norway under all definitions and in all follow-up time periods, regardless of calculation method. Conclusion: The ICR within or between Norway and NC did not differ by definition used. ICR were higher in NC than Norway. There are many potential explanations for the difference.
Resumo:
AIMS: In patients with alcohol dependence, health-related quality of life (QOL) is reduced compared with that of a normal healthy population. The objective of the current analysis was to describe the evolution of health-related QOL in adults with alcohol dependence during a 24-month period after initial assessment for alcohol-related treatment in a routine practice setting, and its relation to drinking pattern which was evaluated across clusters based on the predominant pattern of alcohol use, set against the influence of baseline variables METHODS: The Medical Outcomes Study 36-Item Short-Form Survey (MOS-SF-36) was used to measure QOL at baseline and quarterly for 2 years among participants in CONTROL, a prospective observational study of patients initiating treatment for alcohol dependence. The sample consisted of 160 adults with alcohol dependence (65.6% males) with a mean (SD) age of 45.6 (12.0) years. Alcohol use data were collected using TimeLine Follow-Back. Based on the participant's reported alcohol use, three clusters were identified: 52 (32.5%) mostly abstainers, 64 (40.0%) mostly moderate drinkers and 44 (27.5%) mostly heavy drinkers. Mixed-effect linear regression analysis was used to identify factors that were potentially associated with the mental and physical summary MOS-SF-36 scores at each time point. RESULTS: The mean (SD) MOS-SF-36 mental component summary score (range 0-100, norm 50) was 35.7 (13.6) at baseline [mostly abstainers: 40.4 (14.6); mostly moderate drinkers 35.6 (12.4); mostly heavy drinkers 30.1 (12.1)]. The score improved to 43.1 (13.4) at 3 months [mostly abstainers: 47.4 (12.3); mostly moderate drinkers 44.2 (12.7); mostly heavy drinkers 35.1 (12.9)], to 47.3 (11.4) at 12 months [mostly abstainers: 51.7 (9.7); mostly moderate drinkers 44.8 (11.9); mostly heavy drinkers 44.1 (11.3)], and to 46.6 (11.1) at 24 months [mostly abstainers: 49.2 (11.6); mostly moderate drinkers 45.7 (11.9); mostly heavy drinkers 43.7 (8.8)]. Mixed-effect linear regression multivariate analyses indicated that there was a significant association between a lower 2-year follow-up MOS-SF-36 mental score and being a mostly heavy drinker (-6.97, P < 0.001) or mostly moderate drinker (-3.34 points, P = 0.018) [compared to mostly abstainers], being female (-3.73, P = 0.004), and having a Beck Inventory scale score ≥8 (-6.54, P < 0.001), at baseline. The mean (SD) MOS-SF-36 physical component summary score was 48.8 (10.6) at baseline, remained stable over the follow-up and did not differ across the three clusters. Mixed-effect linear regression univariate analyses found that the average 2-year follow-up MOS-SF-36 physical score was increased (compared with mostly abstainers) in mostly heavy drinkers (+4.44, P = 0.007); no other variables tested influenced the MOS-SF-36 physical score. CONCLUSION: Among individuals with alcohol dependence, a rapid improvement was seen in the mental dimension of QOL following treatment initiation, which was maintained during 24 months. Improvement was associated with the pattern of alcohol use, becoming close to the general population norm in patients classified as mostly abstainers, improving substantially in mostly moderate drinkers and improving only slightly in mostly heavy drinkers. The physical dimension of QOL was generally in the normal range but was not associated with drinking patterns.
Resumo:
There is a need for more efficient methods giving insight into the complex mechanisms of neurotoxicity. Testing strategies including in vitro methods have been proposed to comply with this requirement. With the present study we aimed to develop a novel in vitro approach which mimics in vivo complexity, detects neurotoxicity comprehensively, and provides mechanistic insight. For this purpose we combined rat primary re-aggregating brain cell cultures with a mass spectrometry (MS)-based metabolomics approach. For the proof of principle we treated developing re-aggregating brain cell cultures for 48h with the neurotoxicant methyl mercury chloride (0.1-100muM) and the brain stimulant caffeine (1-100muM) and acquired cellular metabolic profiles. To detect toxicant-induced metabolic alterations the profiles were analysed using commercial software which revealed patterns in the multi-parametric dataset by principal component analyses (PCA), and recognised the most significantly altered metabolites. PCA revealed concentration-dependent cluster formations for methyl mercury chloride (0.1-1muM), and treatment-dependent cluster formations for caffeine (1-100muM) at sub-cytotoxic concentrations. Four relevant metabolites responsible for the concentration-dependent alterations following methyl mercury chloride treatment could be identified using MS-MS fragmentation analysis. These were gamma-aminobutyric acid, choline, glutamine, creatine and spermine. Their respective mass ion intensities demonstrated metabolic alterations in line with the literature and suggest that the metabolites could be biomarkers for mechanisms of neurotoxicity or neuroprotection. In addition, we evaluated whether the approach could identify neurotoxic potential by testing eight compounds which have target organ toxicity in the liver, kidney or brain at sub-cytotoxic concentrations. PCA revealed cluster formations largely dependent on target organ toxicity indicating possible potential for the development of a neurotoxicity prediction model. With such results it could be useful to perform a validation study to determine the reliability, relevance and applicability of this approach to neurotoxicity screening. Thus, for the first time we show the benefits and utility of in vitro metabolomics to comprehensively detect neurotoxicity and to discover new biomarkers.
Resumo:
Peak metamorphic temperatures for the coesite-pyrope-bearing whiteschists from the Dora Maira Massif, western Alps were determined with oxygen isotope thermometry. The deltaO-18(SMOW) values of the quartz (after coesite) (delta O-18 = 8.1 to 8.6 parts per thousand, n = 6), phengite (6.2 to 6.4 parts per thousand, n = 3), kyanite (6.1 parts per thousand, n = 2), garnet (5.5 to 5.8 parts per thousand, n = 9), ellenbergerite (6.3 parts per thousand, n = 1) and rutile (3.3. to 3.6 parts per thousand, n = 3) reflect isotopic equilibrium. Temperature estimates based on quartz-garnet-rutile fractionation are 700-750-degrees-C. Minimum pressures are 31-32 kb based on the pressure-sensitive reaction pyrope + coesite = kyanite + enstatite. In order to stabilize pyrope and coesite by the temperature-sensitive dehydration reaction talc + kyanite = pyrope + coesite + H2O, the a(H2O) must be reduced to 0.4-0.75 at 700 750-degrees-C. The reduced a(H2O) cannot be due to dilution by CO2, as pyrope is not stable at X (CO2) > 0.02 (T = 750-degrees-C; P = 30 kb). In the absence of a more exotic fluid diluent (e.g. CH4 or N2), a melt phase is required. Granite solidus temperatures are approximately 680-degrees-C/30 kb at a(H2O) = 1.0 and are calculated to be approximately 70-degrees-C higher at a(H2O) = 0.7, consistent with this hypothesis. Kyanite-jadeite-quartz bands may represent a relict melt phase. Peak P-T-f(H2O) estimates for the whiteschist are 34 +/- 2 kb, 700-750-degrees-C and 0.4-0.75. The oxygen isotope fractionation between quartz (deltaO-18 = 11.6%.) and garnet (deltaO-18 = 8.7 parts per thousand) in the surrounding orthognesiss is identical to that in the coesite-bearing unit, suggesting that the two units shared a common, final metamorphic history. Hydrogen isotope measurements were made on primary talc and phengite (deltaD(smow) = -27 to -32 parts per thousand), on secondary talc and chlorite after pyrope (deltaD = - 39 to - 44 parts per thousand) and on the surrounding biotite (deltaD = -64 parts per thousand) and phengite (deltaD = -44 parts per thousand) gneiss. All phases appear to be in near-equilibrium. The very high deltaD values for the primary hydrous phases is consistent with an initial oceanic-derived/connate fluid source. The fluid source for the retrograde talc + chlorite after pyrope may be fluids evolved locally during retrograde melt crystallization. The similar deltaD, but dissimilar deltaO-18 values of the coesite-bearing whiteschists and hosting orthogneiss suggest that the two were in hydrogen isotope equilibrium, but not oxygen isotope equilibrium. The unusual hydrogen and oxygen isotope compositions of the coesite-bearing unit can be explained as the result of metasomatism from slab-derived fluids at depth.
Resumo:
Rapport de synthèseLe syndrome d'apnées obstructives du sommeil (SAOS) est une pathologie respiratoire fréquente. Sa prévalence est estimée entre 2 et 5% de la population adulte générale. Ses conséquences sont importantes. Notamment, une somnolence diurne, des troubles de la concentration, des troubles de la mémoire et une augmentation du risque d'accident de la route et du travail. Il représente également un facteur de risque cardiovasculaire indépendant.Ce syndrome est caractérisé par la survenue durant le sommeil d'obstructions répétées des voies aériennes supérieures. L'arrêt ou la diminution d'apport en oxygène vers les poumons entraîne des épisodes de diminution de la saturation en oxygène de l'hémoglobine. Les efforts ventilatoires visant à lever l'obstacle présent sur les voies aériennes causent de fréquents réveils à l'origine d'une fragmentation du sommeil.La polysomnographie (PSG) représente le moyen diagnostic de choix. Il consiste en l'enregistrement dans un laboratoire du sommeil et en présence d'un technicien diplômé, du tracé électroencéphalographique (EEG), de l'électrooculogramme (EOG), de l'électromyogramme mentonnier (EMG), du flux respiratoire nasal, de l'oxymétrie de pouls, de la fréquence cardiaque, de l'électrocardiogramme (ECG), des mouvements thoraciques et abdominaux, de la position du corps et des mouvements des jambes. L'examen est filmé par caméra infrarouge et les sons sont enregistrés.Cet examen permet entre autres mesures, de déterminer les événements respiratoires obstructifs nécessaires au diagnostic de syndrome d'apnée du sommeil. On définit une apnée lors d'arrêt complet du débit aérien durant au moins 10 secondes et une hypopnée en cas, soit de diminution franche de l'amplitude du flux respiratoire supérieure à 50% durant au moins 10 secondes, soit de diminution significative (20%) de l'amplitude du flux respiratoire pendant au minimum 10 secondes associée à un micro-éveil ou à une désaturation d'au moins 3% par rapport à la ligne de base. La détection des micro-éveils se fait en utilisant les dérivations électroencéphalographiques, électromyographiques et électrooculographiques. Il existe des critères visuels de reconnaissance de ces éveils transitoire: apparition de rythme alpha (8.1 à 12.0 Hz) ou beta (16 à 30 Hz) d'une durée supérieure à 3 secondes [20-21].Le diagnostic de S AOS est retenu si l'on retrouve plus de 5 événements respiratoires obstructifs par heure de sommeil associés soit à une somnolence diurne évaluée selon le score d'Epworth ou à au moins 2 symptômes parmi les suivants: sommeil non réparateur, étouffements nocturne, éveils multiples, fatigue, troubles de la concentration. Le S AOS est gradué en fonction du nombre d'événements obstructifs par heure de sommeil en léger (5 à 15), modéré (15 à 30) et sévère (>30).La polysomnographie (PSG) comporte plusieurs inconvénients pratiques. En effet, elle doit être réalisée dans un laboratoire du sommeil avec la présence permanente d'un technicien, limitant ainsi son accessibilité et entraînant des délais diagnostiques et thérapeutiques. Pour ces mêmes raisons, il s'agit d'un examen onéreux.La polygraphie respiratoire (PG) représente l'alternative diagnostique au gold standard qu'est l'examen polysomnographique. Cet examen consiste en l'enregistrement en ambulatoire, à savoir au domicile du patient, du flux nasalrespiratoire, de l'oxymétrie de pouls, de la fréquence cardiaque, de la position du corps et du ronflement (par mesure de pression).En raison de sa sensibilité et sa spécificité moindre, la PG reste recommandée uniquement en cas de forte probabilité de SAOS. Il existe deux raisons principales à l'origine de la moindre sensibilité de l'examen polygraphique. D'une part, du fait que l'état de veille ou de sommeil n'est pas déterminé avec précision, il y a dilution des événements respiratoires sur l'ensemble de l'enregistrement et non sur la période de sommeil uniquement. D'autre part, en l'absence de tracé EEG, la quantification des micro-éveils est impossible. Il n'est donc pas possible dans l'examen poly graphique, de reconnaître une hypopnée en cas de diminution de flux respiratoire de 20 à 50% non associée à un épisode de désaturation de l'hémoglobine de 3% au moins. Alors que dans l'examen polysomnographique, une telle diminution du flux respiratoire pourrait être associée à un micro-éveil et ainsi comptabilisée en tant qu'hypopnée.De ce constat est né la volonté de trouver un équivalent de micro-éveil en polygraphie, en utilisant les signaux à disposition, afin d'augmenter la sensibilité de l'examen polygraphique.Or plusieurs études ont démontrés que les micro-éveils sont associés à des réactions du système nerveux autonome. Lors des micro-éveils, on met en évidence la survenue d'une vasoconstriction périphérique. La variation du tonus sympathique associée aux micro-éveils peut être mesurée par différentes méthodes. Les variations de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie représentant un marqueur fiable de la vasoconstriction périphérique associée aux micro-réveils, il paraît donc opportun d'utiliser ce marqueur autonomique disponible sur le tracé des polygraphies ambulatoires afin de renforcer la sensibilité de cet examen.Le but de l'étude est d'évaluer la sensibilité des variations de l'amplitude de l'onde de pouls pour détecter des micro-réveils corticaux afin de trouver un moyen d'augmenter la sensibilité de l'examen polygraphique et de renforcer ainsi sont pouvoir diagnostic.L'objectif est de démontrer qu'une diminution significative de l'amplitude de l'onde pouls est concomitante à une activation corticale correspondant à un micro¬réveil. Cette constatation pourrait permettre de déterminer une hypopnée, en polygraphie, par une diminution de 20 à 50% du flux respiratoire sans désaturation de 3% mais associée à une baisse significative de l'amplitude de pouls en postulant que l'événement respiratoire a entraîné un micro-réveil. On retrouve par cette méthode les mêmes critères de scoring d'événements respiratoires en polygraphie et en polysomnographie, et l'on renforce la sensibilité de la polygraphie par rapport au gold standard polysomnographique.La méthode consiste à montrer en polysomnographie qu'une diminution significative de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie est associée à une activation du signal électroencéphalographique, en réalisant une analyse spectrale du tracé EEG lors des baisses d'amplitude du signal d'onde de pouls.Pour ce faire nous avons réalisé une étude rétrospective sur plus de 1000 diminutions de l'amplitude de l'onde de pouls sur les tracés de 10 sujets choisis de manière aléatoire parmi les patients référés dans notre centre du sommeil (CIRS) pour suspicion de trouble respiratoire du sommeil avec somnolence ou symptomatologie diurne.Les enregistrements nocturnes ont été effectués de manière standard dans des chambres individuelles en utilisant le système d'acquisition Embla avec l'ensemble des capteurs habituels. Les données ont été par la suite visuellement analysées et mesurées en utilisant le software Somnologica version 5.1, qui fournit un signal de l'amplitude de l'onde de pouls (puise wave amplitude - PWA).Dans un premier temps, un technicien du sommeil a réalisé une analyse visuelle du tracé EEG, en l'absence des données du signal d'amplitude d'onde de pouls. Il a déterminé les phases d'éveil et de sommeil, les stades du sommeil et les micro¬éveils selon les critères standards. Les micro-éveils sont définis lors d'un changement abrupt dans la fréquence de l'EEG avec un pattern d'ondes thêta-alpha et/ou une fréquence supérieure à 16 Hz (en l'absence de fuseau) d'une durée d'au minimum trois secondes. Si cette durée excède quinze secondes, l'événement correspond à un réveil.Puis, deux investigateurs ont analysé le signal d'amplitude d'onde de pouls, en masquant les données du tracé EEG qui inclut les micro-éveils. L'amplitude d'onde de pouls est calculée comme la différence de valeur entre le zénith et le nadir de l'onde pour chaque cycle cardiaque. Pour chaque baisse de l'amplitude d'onde de pouls, la plus grande et la plus petite amplitude sont déterminées et le pourcentage de baisse est calculé comme le rapport entre ces deux amplitudes. On retient de manière arbitraire une baisse d'au moins 20% comme étant significative. Cette limite a été choisie pour des raisons pratiques et cliniques, dès lors qu'elle représentait, à notre sens, la baisse minimale identifiable à l'inspection visuelle. Chaque baisse de PWA retenue est divisée en 5 périodes contiguës de cinq secondes chacune. Deux avant, une pendant et deux après la baisse de PWA.Pour chaque période de cinq secondes, on a pratiqué une analyse spectrale du tracé EEG correspondant. Le canal EEG C4-A1 est analysé en utilisant la transformée rapide de Fourier (FFT) pour chaque baisse de PWA et pour chaque période de cinq secondes avec une résolution de 0.2 Hz. La distribution spectrale est catégorisée dans chaque bande de fréquence: delta (0.5 à 4.0 Hz); thêta (4.1 à 8.0Hz); alpha (8.1 à 12.0 Hz); sigma (12.1 à 16 Hz) et beta (16.1 à 30.0 Hz). La densité de puissance (power density, en μΥ2 ) pour chaque bande de fréquence a été calculée et normalisée en tant que pourcentage de la puissance totale. On a déterminé, ensuite, la différence de densité de puissance entre les 5 périodes par ANOVA on the rank. Un test post hoc Tukey est été utilisé pour déterminer si les différences de densité de puissance étaient significatives. Les calculs ont été effectués à l'aide du software Sigmastat version 3.0 (Systat Software San Jose, California, USA).Le principal résultat obtenu dans cette étude est d'avoir montré une augmentation significative de la densité de puissance de l'EEG pour toutes les bandes de fréquence durant la baisse de l'amplitude de l'onde de pouls par rapport à la période avant et après la baisse. Cette augmentation est par ailleurs retrouvée dans la plupart des bande de fréquence en l'absence de micro-réveil visuellement identifié.Ce résultat témoigné donc d'une activation corticale significative associée à la diminution de l'onde de pouls. Ce résulat pourrait permettre d'utiliser les variations de l'onde de pouls dans les tracés de polygraphie comme marqueur d'une activation corticale. Cependant on peut dire que ce marqueur est plus sensible que l'analyse visuelle du tracé EEG par un technicien puisque qu'on notait une augmentation de lactivité corticale y compris en l'absence de micro-réveil visuellement identifié. L'application pratique de ces résultats nécessite donc une étude prospective complémentaire.