79 resultados para 100-250 µm
Resumo:
BACKGROUND: Frequent emergency department users represent a small number of patients but account for a large number of emergency department visits. They should be a focus because they are often vulnerable patients with many risk factors affecting their quality of life (QoL). Case management interventions have resulted in a significant decrease in emergency department visits, but association with QoL has not been assessed. One aim of our study was to examine to what extent an interdisciplinary case management intervention, compared to standard emergency care, improved frequent emergency department users' QoL. METHODS: Data are part of a randomized, controlled trial designed to improve frequent emergency department users' QoL and use of health-care resources at the Lausanne University Hospital, Switzerland. In total, 250 frequent emergency department users (≥5 attendances during the previous 12 months; ≥ 18 years of age) were interviewed between May 2012 and July 2013. Following an assessment focused on social characteristics; social, mental, and somatic determinants of health; risk behaviors; health care use; and QoL, participants were randomly assigned to the control or the intervention group (n=125 in each group). The final sample included 194 participants (20 deaths, 36 dropouts, n=96 in the intervention group, n=99 in the control group). Participants in the intervention group received a case management intervention by an interdisciplinary, mobile team in addition to standard emergency care. The case management intervention involved four nurses and a physician who provided counseling and assistance concerning social determinants of health, substance-use disorders, and access to the health-care system. The participants' QoL was evaluated by a study nurse using the WHOQOL-BREF five times during the study (at baseline, and at 2, 5.5, 9, and 12 months). Four of the six WHOQOL dimensions of QoL were retained here: physical health, psychological health, social relationship, and environment, with scores ranging from 0 (low QoL) to 100 (high QoL). A linear, mixed-effects model with participants as a random effect was run to analyze the change in QoL over time. The effects of time, participants' group, and the interaction between time and group were tested. These effects were controlled for sociodemographic characteristics and health-related variables (i.e., age, gender, education, citizenship, marital status, type of financial resources, proficiency in French, somatic and mental health problems, and behaviors at risk).
Resumo:
Studies on the role of diet in the development of chronic diseases often rely on self-report surveys of dietary intake. Unfortunately, many validity studies have demonstrated that self-reported dietary intake is subject to systematic under-reporting, although the vast majority of such studies have been conducted in industrialised countries. The aim of the present study was to investigate whether or not systematic reporting error exists among the individuals of African ancestry (n 324) in five countries distributed across the Human Development Index (HDI) scale, a UN statistic devised to rank countries on non-income factors plus economic indicators. Using two 24 h dietary recalls to assess energy intake and the doubly labelled water method to assess total energy expenditure, we calculated the difference between these two values ((self-report - expenditure/expenditure) × 100) to identify under-reporting of habitual energy intake in selected communities in Ghana, South Africa, Seychelles, Jamaica and the USA. Under-reporting of habitual energy intake was observed in all the five countries. The South African cohort exhibited the highest mean under-reporting ( - 52·1% of energy) compared with the cohorts of Ghana ( - 22·5%), Jamaica ( - 17·9%), Seychelles ( - 25·0%) and the USA ( - 18·5%). BMI was the most consistent predictor of under-reporting compared with other predictors. In conclusion, there is substantial under-reporting of dietary energy intake in populations across the whole range of the HDI, and this systematic reporting error increases according to the BMI of an individual.
Resumo:
OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.