165 resultados para delivery accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of acute intravenous dopamine (DA) administration at three sequential (but randomized) infusion rates was studied in eight young male volunteers. DA was infused at 2.5, 5, and 10 micrograms.kg-1.min-1. O2 consumption (VO2) and CO2 production (VCO2) were measured continuously by means of a computerized indirect calorimeter (blood system). In response to the 5- and 10-micrograms.kg-1.min-1 DA infusion rates, a significant increase (P less than 0.01) in VO2 corresponding to a 6% (range, 3-10) and 15% (range, 12-23) increase, respectively, of preinfusion values was observed. In contrast, at the low dose (2.5 micrograms.kg-1.min-1), DA induced no significant change in VO2. Cardiac output (Qc) increased significantly after the three DA administration rates [19% (range, 0-42), 34% (range, 17-71), and 25% (range, -3 to +47)] for the doses 2.5, 5, and 10 micrograms.-kg-1.min-1, respectively. The increase in O2 delivery (QO2) outweighed VO2 at all administration rates despite the relative drop in QO2 at the maximal DA administration rate. These results indicate that in humans DA improves net O2 supply to tissues proportionally more than it increases VO2 at all doses used in the present study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative effectiveness research (CER) allows evidence to be evaluated on the effectiveness, benefits, and detriments of management options, diagnostic tests, or ways to deliver health care. This process can be achieved in different ways, such as with well-designed randomized controlled trials or by meta-analyses. Several medical subspecialties are increasingly using CER, but CER remains underused by the neurosurgical community. Meta-analysis is a highly accurate method that permits results from multiple well-designed research studies to be quantitatively compared. Meta-analysis can be performed in many settings, such as the evaluation of treatment or of a diagnostic test or prognostic factor. Meta-analyses of randomized controlled treatment trials are well known, but there is a paucity of papers describing the ways to perform a meta-analysis of a diagnostic test. The aim of this paper is to improve neurosurgeons' familiarity with the meta-analysis of diagnostic test accuracy by describing and detailing each stage leading to publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cornea transplantation is one of the most performed graft procedures worldwide with an impressive success rate of 90%. However, for "high-risk" patients with particular ocular diseases in addition to the required surgery, the success rate is drastically reduced to 50%. In these cases, cyclosporin A (CsA) is frequently used to prevent the cornea rejection by a systemic treatment with possible systemic side effects for the patients. To overcome these problems, it is a challenge to prepare well-tolerated topical CsA formulations. Normally high amounts of oils or surfactants are needed for the solubilization of the very hydrophobic CsA. Furthermore, it is in general difficult to obtain ocular therapeutic drug levels with topical instillations due to the corneal barriers that efficiently protect the intraocular structures from foreign substances thus also from drugs. The aim of this study was to investigate in vivo the effects of a novel CsA topical aqueous formulation. This formulation was based on nanosized polymeric micelles as drug carriers. An established rat model for the prevention of cornea graft rejection after a keratoplasty procedure was used. After instillation of the novel formulation with fluorescent labeled micelles, confocal analysis of flat-mounted corneas clearly showed that the nanosized carriers were able to penetrate into all corneal layers. The efficacy of a 0.5% CsA micelle formulation was tested and compared to a physiological saline solution and to a systemic administration of CsA. In our studies, the topical CsA treatment was carried out for 14 days, and the three parameters (a) cornea transparency, (b) edema, and (c) neovascularization were evaluated by clinical observation and scoring. Compared to the control group, the treated group showed a significant higher cornea transparency and significant lower edema after 7 and 13 days of the surgery. At the end point of the study, the neovascularization was reduced by 50% in the CsA-micelle treated animals. The success rate of cornea graft transplantation was 73% in treated animals against 25% for the control group. This result was as good as observed for a systemic CsA treatment in the same animal model. This new formulation has the same efficacy like a systemic treatment but without the serious CsA systemic side effects. Ocular drug levels of transplanted and healthy rat eyes were dosed by UPLC/MS and showed a high CsA value in the cornea (11710 ± 7530 ng(CsA)/g(tissue) and 6470 ± 1730 ng(CsA)/g(tissue), respectively). In conclusion, the applied formulation has the capacity to overcome the ocular surface barriers, the micelles formed a drug reservoir in the cornea from, where a sustained release of CsA can take place. This novel formulation for topical application of CsA is clearly an effective and well-tolerated alternative to the systemic treatment for the prevention of corneal graft rejection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prevention of cardiovascular disease (CVD) at the individual level should rely on the assessment of absolute risk using population-specific risk tables. OBJECTIVE: To compare the predictive accuracy of the original and the calibrated SCORE functions regarding 10-year cardiovascular risk in Switzerland. DESIGN: Cross-sectional, population-based study (5773 participants aged 35-74 years). METHODS: The SCORE equation for low-risk countries was calibrated based on the Swiss CVD mortality rates and on the CVD risk factor levels from the study sample. The predicted number of CVD deaths after a 10-year period was computed from the original and the calibrated equations and from the observed cardiovascular mortality for 2003. RESULTS: According to the original and calibrated functions, 16.3 and 15.8% of men and 8.2 and 8.9% of women, respectively, had a 10-year CVD risk > or =5%. Concordance correlation coefficient between the two functions was 0.951 for men and 0.948 for women, both P<0.001. Both risk functions adequately predicted the 10-year cumulative number of CVD deaths: in men, 71 (original) and 74 (calibrated) deaths for 73 deaths when using the CVD mortality rates; in women, 44 (original), 45 (calibrated) and 45 (CVD mortality rates), respectively. Compared to the original function, the calibrated function classified more women and fewer men at high-risk. Moreover, the calibrated function gave better risk estimates among participants aged over 65 years. CONCLUSION: The original SCORE function adequately predicts CVD death in Switzerland, particularly for individuals aged less than 65 years. The calibrated function provides more reliable estimates for older individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The pre-treatment of tumor neo-vessels by photodynamic therapy (PDT) was shown to improve the distribution of chemotherapy administered subsequently. However, the precise mechanism by which PDT modifies the tumor vasculature is unknown. We have recently shown that leukocyteendothelial cell interaction was essential for PDT induced drug delivery to normal tissue. Our purpose was to determine if PDT could enhance drug distribution in malignant mesothelioma and if a comparable role for leucocytes existed.Methods: We grew human mesothelioma xenografts (H-meso-1) in the dorsal skinfold chambers of nude mice (n = 28). The rolling, sticking and recruitment of leucocytes was assessed in tumor and normal vessels following PDT (Visudyne 0?4 mg/kg, fluence rate 200 mW/cm2, fluence 60 J/cm2) using intravital microscopy. In parallel, the distribution of a macromolecule (FITC dextran, 2000 kDa) administered after PDT was determined. We compared these variables in control (no PDT), PDT + IgG (non specific antibody) and PDT + pan-selectin antibody (monoclonal P-E-L selectin antibody).Results: PDT significantly enhanced the distribution of FITC dextran in mesothelioma xenografts compared to controls. Interestingly, PDT enhanced the leukocyte-endothelial interaction significantly (rolling and recruitment)in tumor and surrounding normal vessels compared to controls. Leukocyte recruitment was significantly down-regulated by pan-selectin antibodies in tumor tissues. However, the suppression of leucocyte recruitement did not affect the extravasation of FITC-dextran in tumor tissue.Conclusion:PDTpre-treatment of the mesothelioma vasculature can enhance the distribution of macromolecular drugs administered subsequently. However, unlike normal vessels, leukocyte-endothelial cell interaction is not required for PDT induced leakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficient vaccination against infectious agents and tumors depends on specific antigen targeting to dendritic cells (DCs). We report here that biosafe coronavirus-based vaccine vectors facilitate delivery of multiple antigens and immunostimulatory cytokines to professional antigen-presenting cells in vitro and in vivo. Vaccine vectors based on heavily attenuated murine coronavirus genomes were generated to express epitopes from the lymphocytic choriomeningitis virus glycoprotein, or human Melan-A, in combination with the immunostimulatory cytokine granulocyte-macrophage colony-stimulating factor (GM-CSF). These vectors selectively targeted DCs in vitro and in vivo resulting in vector-mediated antigen expression and efficient maturation of DCs. Single application of only low vector doses elicited strong and long-lasting cytotoxic T-cell responses, providing protective antiviral and antitumor immunity. Furthermore, human DCs transduced with Melan-A-recombinant human coronavirus 229E efficiently activated tumor-specific CD8(+) T cells. Taken together, this novel vaccine platform is well suited to deliver antigens and immunostimulatory cytokines to DCs and to initiate and maintain protective immunity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sentinel or tumor-draining lymph node (tdLN) serves as a metastatic niche for many solid tumors and is altered via tumor-derived factors that support tumor progression and metastasis. tdLNs are often removed surgically, and therapeutic vaccines against tumor antigens are typically administered systemically or in non-tumor-associated sites. Although the tdLN is immune-suppressed, it is also antigen experienced through drainage of tumor-associated antigens (TAA), so we asked whether therapeutic vaccines targeting the tdLN would be more or less effective than those targeting the non-tdLN. Using LN-targeting nanoparticle (NP)-conjugate vaccines consisting of TAA-NP and CpG-NP, we compared delivery to the tdLN versus non-tdLN in two different cancer models, E.G7-OVA lymphoma (expressing the nonendogenous TAA ovalbumin) and B16-F10 melanoma. Surprisingly, despite the immune-suppressed state of the tdLN, tdLN-targeting vaccination induced substantially stronger cytotoxic CD8+ T-cell responses, both locally and systemically, than non-tdLN-targeting vaccination, leading to enhanced tumor regression and host survival. This improved tumor regression correlated with a shift in the tumor-infiltrating leukocyte repertoire toward a less suppressive and more immunogenic balance. Nanoparticle coupling of adjuvant and antigen was required for effective tdLN targeting, as nanoparticle coupling dramatically increased the delivery of antigen and adjuvant to LN-resident antigen-presenting cells, thereby increasing therapeutic efficacy. This work highlights the tdLN as a target for cancer immunotherapy and shows how its antigen-experienced but immune-suppressed state can be reprogrammed with a targeted vaccine yielding antitumor immunity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Co-morbidity information derived from administrative data needs to be validated to allow its regular use. We assessed evolution in the accuracy of coding for Charlson and Elixhauser co-morbidities at three time points over a 5-year period, following the introduction of the International Classification of Diseases, 10th Revision (ICD-10), coding of hospital discharges.METHODS: Cross-sectional time trend evaluation study of coding accuracy using hospital chart data of 3'499 randomly selected patients who were discharged in 1999, 2001 and 2003, from two teaching and one non-teaching hospital in Switzerland. We measured sensitivity, positive predictive and Kappa values for agreement between administrative data coded with ICD-10 and chart data as the 'reference standard' for recording 36 co-morbidities.RESULTS: For the 17 the Charlson co-morbidities, the sensitivity - median (min-max) - was 36.5% (17.4-64.1) in 1999, 42.5% (22.2-64.6) in 2001 and 42.8% (8.4-75.6) in 2003. For the 29 Elixhauser co-morbidities, the sensitivity was 34.2% (1.9-64.1) in 1999, 38.6% (10.5-66.5) in 2001 and 41.6% (5.1-76.5) in 2003. Between 1999 and 2003, sensitivity estimates increased for 30 co-morbidities and decreased for 6 co-morbidities. The increase in sensitivities was statistically significant for six conditions and the decrease significant for one. Kappa values were increased for 29 co-morbidities and decreased for seven.CONCLUSIONS: Accuracy of administrative data in recording clinical conditions improved slightly between 1999 and 2003. These findings are of relevance to all jurisdictions introducing new coding systems, because they demonstrate a phenomenon of improved administrative data accuracy that may relate to a coding 'learning curve' with the new coding system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liposomes are vesicular lipidic systems allowing encapsulation of drugs. This article reviews the relevant issues in liposome structure (composition and size), and their influence on intravitreal pharmacokinetics. Liposome-mediated drug delivery to the posterior segment of the eye via intravitreal administration has been addressed by several authors and remains experimental. Liposomes have been used for intravitreal delivery of antibiotics, antivirals, antifungal drugs, antimetabolites, and cyclosporin. Encapsulation of these drugs within liposomes markedly increased their intravitreal half-life, and reduced their retinal toxicity. Liposomes have also shown an attractive potential for retinal gene transfer by intravitreal delivery of plasmids or oligonucleotides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Most national guidelines for the prevention of mother-to-child transmission of HIV in Europe updated between 2001 and 2010 recommend vaginal deliveries for women with undetectable or very low viral load (VL). Our aim was to explore the impact of these new guidelines on the rates of vaginal deliveries among HIV-positive women in Europe. METHODS: In a pooled analysis of data on HIV-positive pregnant women enrolled in the Swiss Mother & Child HIV Cohort Study and the European Collaborative Study 2000 to 2010, deliveries were classified as occurring pre- or postpublication of national guidelines recommending vaginal delivery. RESULTS: Overall, 2663 women with 3013 deliveries were included from 10 countries; 28% women were diagnosed with HIV during pregnancy. Combination antiretroviral therapy was used in most pregnancies (2020, 73%), starting during the first or second trimester in 78% and during the third trimester in 22%; in 25% pregnancies, the woman conceived on combination antiretroviral therapy. Overall, in 86% pregnancies, a VL < 400 copies per milliliter was achieved before delivery. The proportion of vaginal deliveries increased from 17% (414/2377) before the change in guidelines to 52% (313/600) after; elective Caesarean section rates decreased from 65% to 27%. The proportion of women with undetectable VL having a Caesarean section was 55% after implementation of new guidelines. We observed a decrease of late preterm deliveries from 16% (377/2354) before to 7% (42/599) after the change in guidelines (P < 0.001). CONCLUSION: There are still missed opportunities for women with HIV to fully suppress their VL and to deliver vaginally in Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Up to now, the different uptake pathways and the subsequent intracellular trafficking of plasmid DNA have been largely explored. By contrast, the mode of internalization and the intracellular routing of an exogenous mRNA in transfected cells are poorly investigated and remain to be elucidated. The bioavailability of internalized mRNA depends on its intracellular routing and its potential accumulation in dynamic sorting sites for storage: stress granules and processing bodies. This question is of particular significance when a secure transposon-based system able to integrate a therapeutic transgene into the genome is used. Transposon vectors usually require two components: a plasmid DNA, carrying the gene of interest, and a source of transposase allowing the integration of the transgene. The principal drawback is the lasting presence of the transposase, which could remobilize the transgene once it has been inserted. Our study focused on the pharmacokinetics of the transposition process mediated by the piggyBac transposase mRNA transfection. Exogenous mRNA internalization and trafficking were investigated towards a better apprehension and fine control of the piggyBac transposase bioavailability. RESULTS: The mRNA prototype designed in this study provides a very narrow expression window of transposase, which allows high efficiency transposition with no cytotoxicity. Our data reveal that exogenous transposase mRNA enters cells by clathrin and caveolae-mediated endocytosis, before finishing in late endosomes 3 h after transfection. At this point, the mRNA is dissociated from its carrier and localized in stress granules, but not in cytoplasmic processing bodies. Some weaker signals have been observed in stress granules at 18 h and 48 h without causing prolonged production of the transposase. So, we designed an mRNA that is efficiently translated with a peak of transposase production 18 h post-transfection without additional release of the molecule. This confines the integration of the transgene in a very small time window. CONCLUSION: Our results shed light on processes of exogenous mRNA trafficking, which are crucial to estimate the mRNA bioavailability, and increase the biosafety of transgene integration mediated by transposition. This approach provides a new way for limiting the transgene copy in the genome and their remobilization by mRNA engineering and trafficking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.