92 resultados para collaborative planning
Resumo:
A second collaborative exercise on RNA/DNA co-analysis for body fluid identification and STR profiling was organized by the European DNA Profiling Group (EDNAP). Six human blood stains, two blood dilution series (5-0.001 μl blood) and, optionally, bona fide or mock casework samples of human or non-human origin were analyzed by the participating laboratories using a RNA/DNA co-extraction or solely RNA extraction method. Two novel mRNA multiplexes were used for the identification of blood: a highly sensitive duplex (HBA, HBB) and a moderately sensitive pentaplex (ALAS2, CD3G, ANK1, SPTB and PBGD). The laboratories used different chemistries and instrumentation. All of the 18 participating laboratories were able to successfully isolate and detect mRNA in dried blood stains. Thirteen laboratories simultaneously extracted RNA and DNA from individual stains and were able to utilize mRNA profiling to confirm the presence of blood and to obtain autosomal STR profiles from the blood stain donors. The positive identification of blood and good quality DNA profiles were also obtained from old and compromised casework samples. The method proved to be reproducible and sensitive using different analysis strategies. The results of this collaborative exercise involving a RNA/DNA co-extraction strategy support the potential use of an mRNA based system for the identification of blood in forensic casework that is compatible with current DNA analysis methodology.
Resumo:
The burden of disease linked to mental disorders represents more than one-fifth of years lived with disability in the world. Less than half of people suffering from mental disorders are adequately treated. Three quarter of those who receive treatment are followed by primary care. Collaborative care aims to increase the efficiency of direct general practitioner's treatment. Main components are sustainable and individualized consultation-liaison relationship (1/2 day of psychiatrist by 15 days for 10-15 general practitioners), and support of a clinical case manager for complex situations. Collaboration is bidirectional: early or crisis access to specialist care and long-term followup by general practitioner. This model is a challenge for the doctor-patient dual relationship and requires incentives in a public health perspective.
Resumo:
We performed an international proficiency study of Human Papillomavirus (HPV) type 16 serology. A common methodology for serology based on virus-like particle (VLP) ELISA was used by 10 laboratories in 6 continents. The laboratories used the same VLP reference reagent, which was selected as the most stable, sensitive and specific VLP preparation out of VLPs donated from 5 different sources. A blinded proficiency panel consisting of 52 serum samples from women with PCR-verified HPV 16-infection, 11 control serum samples from virginal women and the WHO HPV 16 International Standard (IS) serum were distributed. The mean plus 3 standard deviations of the negative control serum samples was the most generally useful "cut-off" criterion for distinguishing positive and negative samples. Using sensitivity of at least 50% and a specificity of 100% as proficiency criteria, 6/10 laboratories were proficient. In conclusion, an international Standard Operating Procedure for HPV serology, an international reporting system in International Units (IU) and a common "cut-off" criterion have been evaluated in an international HPV serology proficiency study.
Resumo:
In this paper, we present the segmentation of the headand neck lymph node regions using a new active contourbased atlas registration model. We propose to segment thelymph node regions without directly including them in theatlas registration process; instead, they are segmentedusing the dense deformation field computed from theregistration of the atlas structures with distinctboundaries. This approach results in robust and accuratesegmentation of the lymph node regions even in thepresence of significant anatomical variations between theatlas-image and the patient's image to be segmented. Wealso present a quantitative evaluation of lymph noderegions segmentation using various statistical as well asgeometrical metrics: sensitivity, specificity, dicesimilarity coefficient and Hausdorff distance. Acomparison of the proposed method with two other state ofthe art methods is presented. The robustness of theproposed method to the atlas selection, in segmenting thelymph node regions, is also evaluated.
Resumo:
For radiotherapy treatment planning of retinoblastoma inchildhood, Computed Tomography (CT) represents thestandard method for tumor volume delineation, despitesome inherent limitations. CT scan is very useful inproviding information on physical density for dosecalculation and morphological volumetric information butpresents a low sensitivity in assessing the tumorviability. On the other hand, 3D ultrasound (US) allows ahigh accurate definition of the tumor volume thanks toits high spatial resolution but it is not currentlyintegrated in the treatment planning but used only fordiagnosis and follow-up. Our ultimate goal is anautomatic segmentation of gross tumor volume (GTV) in the3D US, the segmentation of the organs at risk (OAR) inthe CT and the registration of both. In this paper, wepresent some preliminary results in this direction. Wepresent 3D active contour-based segmentation of the eyeball and the lens in CT images; the presented approachincorporates the prior knowledge of the anatomy by usinga 3D geometrical eye model. The automated segmentationresults are validated by comparing with manualsegmentations. Then, for the fusion of 3D CT and USimages, we present two approaches: (i) landmark-basedtransformation, and (ii) object-based transformation thatmakes use of eye ball contour information on CT and USimages.
Resumo:
PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV).
Resumo:
La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.
Resumo:
BACKGROUND: Maternal-infant transmission of hepatitis B virus (HBV) during birth carries a high risk for chronic HBV infection in infants with frequent subsequent development of chronic disease. This can be efficiently prevented by early immunization of exposed newborns. The purpose of this study was to determine the compliance with official recommendations for prevention of perinatal HBV transmission in hepatitis B surface antigen (HBsAg) exposed infants. METHODS: Records of pregnant women at 4 sites in Switzerland, admitted for delivery in 2005 and 2006, were screened for maternal HBsAg testing. In HBsAg-exposed infants, recommended procedures (postnatal active and passive immunization, completion of immunization series, and serological success control) were checked. RESULTS: Of 27,131 women tested for HBsAg, 194 (0.73%) were positive with 196 exposed neonates. Of these neonates, 143 (73%) were enrolled and 141 (99%) received simultaneous active and passive HBV immunization within 24 hours of birth. After discharge, the HBV immunization series was completed in 83%. Only 38% of children were tested for anti-HBs afterwards and protective antibody values (>100 U/L) were documented in 27% of the study cohort. No chronically infected child was identified. Analysis of hospital discharge letters revealed significant quality problems. CONCLUSIONS: Intensified efforts are needed to improve the currently suboptimal medical care in HBsAg-exposed infants. We propose standardized discharge letters, as well as reminders to primary care physicians with precise instructions on the need to complete the immunization series in HBsAg-exposed infants and to evaluate success by determination of anti-HBs antibodies after the last dose.