92 resultados para Routine formulas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Many patients may believe that HIV screening is included in routine preoperative work-ups. We examined what proportion of patients undergoing preoperative blood testing believed that they had been tested for HIV. METHODS: All patients hospitalized for elective orthopaedic surgery between January and December 2007 were contacted and asked to participate in a 15-min computer-assisted telephone interview (n = 1330). The primary outcome was to determine which preoperative tests patients believed had been performed from a choice of glucose, clotting, HIV serology and cholesterol, and what percentage of patients interpreted the lack of result communication as a normal or negative test. The proportion of patients agreeable to HIV screening prior to future surgery was also determined. RESULTS: A total of 991 patients (75%) completed the questionnaire. Three hundred and seventy-five of these 991 patients (38%) believed incorrectly that they had been tested for HIV preoperatively. Younger patients were significantly more likely to believe that an HIV test had been performed (mean age 46 vs. 50 years for those who did not believe that an HIV test had been performed; P < 0.0001). Of the patients who believed that a test had been performed but received no result, 96% interpreted lack of a result as a negative HIV test. Over 80% of patients surveyed stated that they would agree to routine HIV screening prior to future surgery. A higher acceptance rate was associated with younger age (mean age 47 years for those who would agree vs. 56 years for those who would not; P < 0.0001) and male sex ( P < 0.009). CONCLUSIONS: Many patients believe that a preoperative blood test routinely screens for HIV. The incorrect assumption that a lack of result communication indicates a negative test may contribute to delays in HIV diagnoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Only few countries have cohorts enabling specific and up-to-date cardiovascular disease (CVD) risk estimation. Individual risk assessment based on study samples that differ too much from the target population could jeopardize the benefit of risk charts in general practice. Our aim was to provide up-to-date and valid CVD risk estimation for a Swiss population using a novel record linkage approach. METHODS: Anonymous record linkage was used to follow-up (for mortality, until 2008) 9,853 men and women aged 25-74 years who participated in the Swiss MONICA (MONItoring of trends and determinants in CVD) study of 1983-92. The linkage success was 97.8%, loss to follow-up 1990-2000 was 4.7%. Based on the ESC SCORE methodology (Weibull regression), we used age, sex, blood pressure, smoking, and cholesterol to generate three models. We compared the 1) original SCORE model with a 2) recalibrated and a 3) new model using the Brier score (BS) and cross-validation. RESULTS: Based on the cross-validated BS, the new model (BS = 14107×10(-6)) was somewhat more appropriate for risk estimation than the original (BS = 14190×10(-6)) and the recalibrated (BS = 14172×10(-6)) model. Particularly at younger age, derived absolute risks were consistently lower than those from the original and the recalibrated model which was mainly due to a smaller impact of total cholesterol. CONCLUSION: Using record linkage of observational and routine data is an efficient procedure to obtain valid and up-to-date CVD risk estimates for a specific population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study aimed to explore the validity of an adaptation into French of the self-rated form of the Health of the Nation Outcome Scales for Children and Adolescents (F-HoNOSCA-SR) and to test its usefulness in a clinical routine use. One hundred and twenty nine patients, admitted into two inpatient units, were asked to participate in the study. One hundred and seven patients filled out the F-HoNOSCA-SR (for a subsample (N=17): at two occasions, one week apart) and the strengths and difficulties questionnaire (SDQ). In addition, the clinician rated the clinician-rated form of the HoNOSCA (HoNOSCA-CR, N=82). The reliability (assessed with split-half coefficient, item response theory (IRT) models and intraclass correlations (ICC) between the two occasions) revealed that the F-HoNSOCA-SR provides reliable measures. The concurrent validity assessed by correlating the F-HoNOSCA-SR and the SDQ revealed a good convergent validity of the instrument. The relationship analyses between the F-HoNOSCA-SR and the HoNOSCA-CR revealed weak but significant correlations. The comparison between the F-HoNOSCA-SR and the HoNOSCA-CR with paired sample t-tests revealed a higher score for the self-rated version. The F-HoNSOCA-SR was reported to provide reliable measures. In addition, it allows us to measure complementary information when used together with the HoNOSCA-CR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Estimation of glomerular filtration rate (eGFR) using a common formula for both adult and pediatric populations is challenging. Using inulin clearances (iGFRs), this study aims to investigate the existence of a precise age cutoff beyond which the Modification of Diet in Renal Disease (MDRD), the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), or the Cockroft-Gault (CG) formulas, can be applied with acceptable precision. Performance of the new Schwartz formula according to age is also evaluated. METHOD: We compared 503 iGFRs for 503 children aged between 33 months and 18 years to eGFRs. To define the most precise age cutoff value for each formula, a circular binary segmentation method analyzing the formulas' bias values according to the children's ages was performed. Bias was defined by the difference between iGFRs and eGFRs. To validate the identified cutoff, 30% accuracy was calculated. RESULTS: For MDRD, CKD-EPI and CG, the best age cutoff was ≥14.3, ≥14.2 and ≤10.8 years, respectively. The lowest mean bias and highest accuracy were -17.11 and 64.7% for MDRD, 27.4 and 51% for CKD-EPI, and 8.31 and 77.2% for CG. The Schwartz formula showed the best performance below the age of 10.9 years. CONCLUSION: For the MDRD and CKD-EPI formulas, the mean bias values decreased with increasing child age and these formulas were more accurate beyond an age cutoff of 14.3 and 14.2 years, respectively. For the CG and Schwartz formulas, the lowest mean bias values and the best accuracies were below an age cutoff of 10.8 and 10.9 years, respectively. Nevertheless, the accuracies of the formulas were still below the National Kidney Foundation Kidney Disease Outcomes Quality Initiative target to be validated in these age groups and, therefore, none of these formulas can be used to estimate GFR in children and adolescent populations.