61 resultados para REPOSITIONING PROCEDURE
Resumo:
BACKGROUND: The preservation of globe integrity has always been a major concern during the treatment of retinoblastoma for fear of extraocular or metastatic spread. Intravitreal chemotherapy has been attempted as a desperate salvage therapy only for eyes with refractory retinoblastoma. Published data on the safety and efficacy of this route are, however, limited. METHODS: A modified technique of intravitreal injection in eyes with retinoblastoma is described. All children with retinoblastoma who received one or more intravitreal injections using this technique were retrospectively reviewed concerning ocular complications of the injection procedure as well as clinical or histopathological evidence of tumour spread. RESULTS: 30 eyes of 30 children with retinoblastoma received a total of 135 intravitreal injections, with a median follw-up duration of 13.5 months. No extraocular spread was seen on clinical follow-up in any patients and there was no tumour contamination of the retrieved entry sites histopathologically analysed among the five enucleated eyes. No significant ocular side effects were observed except transient localised vitreous haemorrhage (3/135). CONCLUSION: This technique is potentially safe and effective at a low cost and may play a promising role, especially in the treatment of recurrent and/or resistant vitreous disease in retinoblastoma, as an alternative to enucleation and/or external beam radiotherapy. However, this treatment should not replace the primary standard of care of retinoblastoma and should not be considered in group E eyes. Its application should be approved by an ophthalmological-oncological team and it should be performed by an experienced eye surgeon in a tertiary referral centre after careful selection of a tumour-free injection site.
Resumo:
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Resumo:
This article describes the application of a recently developed general unknown screening (GUS) strategy based on LC coupled to a hybrid linear IT-triple quadrupole mass spectrometer (LC-MS/MS-LIT) for the simultaneous detection and identification of drug metabolites following in vitro incubation with human liver microsomes. The histamine H1 receptor antagonist loratadine was chosen as a model compound to demonstrate the interest of such approach, because of its previously described complex and extensive metabolism. Detection and mass spectral characterization were based on data-dependent acquisition, switching between a survey scan acquired in the ion-trapping Q3 scan mode with dynamic subtraction of background noise, and a dependent scan in the ion-trapping product ion scan mode of automatically selected parent ions. In addition, the MS(3) mode was used in a second step to confirm the structure of a few fragment ions. The sensitivity of the ion-trapping modes combined with the selectivity of the triple quadrupole modes allowed, with only one injection, the detection and identification of 17 phase I metabolites of loratadine. The GUS procedure used in this study may be applicable as a generic technique for the characterization of drug metabolites after in vitro incubation, as well as probably in vivo experiments.
Resumo:
Semi-automatic capillary gas chromatographic method with classical flame ionization detection, which satisfies the conditions for required performance and gave acceptable results within the framework of an interlaboratory certification programme for PAHs in sewage sludge, is described. The interesting feature of the procedure is that it incorporates automatic operations such as sample fractionation by semi-preparative HPLC, fraction collection at signal level recognition and evaporation under nitrogen flow. Multiple injections in the GC capillary column are performed in the on-column mode via an autosampler with temperature-programmable injector. Automatic data acquisition and chromatogram treatment are made via computer software. This partially automatic procedure releases personnel from tedious and time-consuming tasks and its robust character was validated through the certification of reference material for PAHs in sewage sludge, demonstrating its reliable performance.
Resumo:
BACKGROUND: Total orbital exenteration is a radical surgical procedure, which typically involves the removal of the entire contents of the orbit including the periorbita, leaving the patient with a deep orbital deformity and results in devastating cosmetic, functional, and psychological consequences requiring difficult and challenging procedures for oculoplastic surgeons. Oculofacial prostheses retained by endosseous dental implants present an attractive and viable alternative when aesthetic and functional demands are beyond the capacity of local reconstructive efforts. PATIENTS AND METHODS: A 72-year-old woman presenting a malignant melanoma of the right eyelids and a 77-year-old man presenting a sebaceous carcinoma of the left upper eyelid underwent a total exenteration followed by positioning of endosseous implants (Straumann system Dental implants) as an integrated one-step combined surgical procedure. The oculofacial prosthesis was placed after epithelialization of the orbital cavity. RESULTS: The implants were perfectly osseointegrated without any complications, providing sufficient retention of the prostheses. A satisfactory aesthetic outcome has been achieved for both patients. CONCLUSIONS: Oculofacial prostheses anchored by osseointegrated dental implants placed as one-step surgical procedure ensure an adequate aesthetic result as well as a considerably decreased rehabilitation time and present a satisfactory solution when reconstruction is not a suitable option.
Resumo:
Introduction: Ankle sprains affect 200'000 persons/year in Switzerland. Most incidences are successfully treated by conservative measures but 20% require reconstruction for symptomatic chronic lateral ankle instability. This study evaluates the functional outcome after a modified Broström-Gould technique as measured by different clinical scores and compares the functional outcome of this technique with other surgical treatments of ankle instability. Methods: This retrospective cohort study evaluates 47 patients who underwent a modified Broström-Gould procedure using suture anchors to refix the lateral ankle capsuloligamentary structures at our institution from 2005 to 2009 with a minimum follow-up of one year (13-72 Mo). All patients were operated by one single surgeon and evaluated by an independent examiner. The function was assessed using 4 scores including: the AOFAS (American Orthopaedic Foot and Ankle Society's Score) hindfoot score; the FAAM (Foot and Ankle Ability Measurement); the CAIT (Cumberland Ankle Instability Tool); the CAIS (Chronic Ankle Instability Scale). Results: Six patients were excluded leaving 41 patients for examination. 34 patients (83%) thought that their ankle was more stable after the surgery, 7 (17%) did not feel any difference. 27 patients were very satisfied, 11 satisfied and 3 not satisfied. Reasons for non satisfaction included persistent instability and pain. Ankle mobility returned to normal in 93% of patients. Five patients had transcient hypoesthesy in the area of the superficial peroneal nerve. One patient suffered from a superficial infection treated successfully by local measures. 80% had the perception of a normal ankle, 20% thought to be below normal. At follow-up the AOFAS was 89/100 (37-100), the FAAM 85/100% (35-100%), the CAIT 20/30 (5-30), and the CAIS 74/100% (27-100%). Conclusions: The modified Broström-Gould procedure, which belongs to the anatomic ankle stabilizations is relatively simple and offers good outcome that satisfied 93% of the patients in the present study. No active stabilisator is sacrificed. Preservation of the ankle mobility is better and the complication rate is lower than after non-anatomical procedures described in the literature. The CAIT appeared as the most severe score compared to the other scales used in our study.
Resumo:
The ideal reconstruction technique for complex defects of the lower limb consists of replacing tissue with similar tissue in an attempt to achieve a good functional result. A 23-year-old white male sustained a crush injury with a grade IIIB open ankle dislocation. After open reduction and fixation, the patient developed severe osteomyelitis at the tibiotalar joint requiring a staged and radical debridement with a substantial combined soft tissue and bony defect over the distal tibia, fibula, and talus area. The reconstructive approach consisted of a modified model of the propeller flap, implementing the spare part concept in a 2-stage procedure using a prefabricated and vascularized "double-barrel" fibular graft. At 17 months postoperatively, a plain radiograph showed bony union with complete and stable coverage of the soft tissue defect. The patient was fully weightbearing. In conclusion, there is evidence to suggest that the established concept of a soft tissue propeller flap can be implemented on bone.
Resumo:
We present the case of a 45-year-old woman with a history of multiple back surgeries to illustrate the feasibility of combining CT myelography (myeloCT) and Tc-HDP SPECT/CT bone scan in a 1-step procedure to realize a combined SPECT-myeloCT. Myelography CT and SPECT/CT were required to assess nerve root compression and pseudarthrosis, respectively. The proposed combined acquisition protocol provides information about nervous compression as well as pseudarthrosis in a 1 examination, optimizing radiation dose and patient comfort.