86 resultados para Concentration minimale inhibitrice


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have recently shown that at isotopic steady state (13)C NMR can provide a direct measurement of glycogen concentration changes, but that the turnover of glycogen was not accessible with this protocol. The aim of the present study was to design, implement and apply a novel dual-tracer infusion protocol to simultaneously measure glycogen concentration and turnover. After reaching isotopic steady state for glycogen C1 using [1-(13)C] glucose administration, [1,6-(13)C(2)] glucose was infused such that isotopic steady state was maintained at the C1 position, but the C6 position reflected (13)C label incorporation. To overcome the large chemical shift displacement error between the C1 and C6 resonances of glycogen, we implemented 2D gradient based localization using the Fourier series window approach, in conjunction with time-domain analysis of the resulting FIDs using jMRUI. The glycogen concentration of 5.1 +/- 1.6 mM measured from the C1 position was in excellent agreement with concomitant biochemical determinations. Glycogen turnover measured from the rate of label incorporation into the C6 position of glycogen in the alpha-chloralose anesthetized rat was 0.7 micromol/g/h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This study assessed whether a cycle of "routine" therapeutic drug monitoring (TDM) for imatinib dosage individualization, targeting an imatinib trough plasma concentration (C min) of 1,000 ng/ml (tolerance: 750-1,500 ng/ml), could improve clinical outcomes in chronic myelogenous leukemia (CML) patients, compared with TDM use only in case of problems ("rescue" TDM). METHODS: Imatinib concentration monitoring evaluation was a multicenter randomized controlled trial including adult patients in chronic or accelerated phase CML receiving imatinib since less than 5 years. Patients were allocated 1:1 to "routine TDM" or "rescue TDM." The primary endpoint was a combined outcome (failure- and toxicity-free survival with continuation on imatinib) over 1-year follow-up, analyzed in intention-to-treat (ISRCTN31181395). RESULTS: Among 56 patients (55 evaluable), 14/27 (52 %) receiving "routine TDM" remained event-free versus 16/28 (57 %) "rescue TDM" controls (P = 0.69). In the "routine TDM" arm, dosage recommendations were correctly adopted in 14 patients (median C min: 895 ng/ml), who had fewer unfavorable events (28 %) than the 13 not receiving the advised dosage (77 %; P = 0.03; median C min: 648 ng/ml). CONCLUSIONS: This first target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" because of small patient number and surprisingly limited prescriber's adherence to dosage recommendations. Favorable outcomes were, however, found in patients actually elected for target dosing. This study thus shows first prospective indication for TDM being a useful tool to guide drug dosage and shift decisions. The study design and analysis provide an interesting paradigm for future randomized TDM trials on targeted anticancer agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The widespread use of combination antiretroviral therapy (ARVs) has considerably improved the prognosis of patients infected with HIV. Conversely, considerable advances have been recently realized for the therapy of hepatitis C infection with the recent advent of potent new anti-HCV drugs that allow an increasing rate HCV infection cure. Despite their overall efficacy, a significant number of patients do not achieve or maintain adequate clinical response, defined as an undetectable viral load for HIV, and a sustained virological response (or cure) in HCV infection. Treatment failure therefore still remains an important issue besides drugs toxicities and viral resistance which is not uncommon in a significant percentage of patients who do not reach adequate virological suppression. The reasons of variability in drug response are multifactorial and apart from viral genetics, other factors such as environmental factors, drug- drug interactions, and imperfect compliance may have profound impact on antiviral drugs' clinical response. The possibility of measuring plasma concentration of antiviral drugs enables to guide antiviral drug therapy and ensure optimal drug exposure. The overall objective of this research was to widen up the current knowledge on pharmacokinetic and pharmacogenetic factors that influence the clinical response and toxicity of current and newly approved antiretroviral and anti-HCV drugs. To that endeavour, analytical methods using liquid chromatography coupled with tandem mass spectrometry have been developed and validated for the precise and accurate measurement of new antiretroviral and anti-HCV drugs . These assays have been applied for the TDM of ARVs and anti-HCV in patients infected with either HIV or HCV respectively, and co-infected with HIV- HCV. A pharmacokinetic population model was developed to characterize inter and intra-patient variability of rilpivirine, the latest marketed Non Nucleoside Reverse transcriptase (NNRTI) Inhibitor of HIVand to identify genetic and non genetic covariates influencing rilpivirine exposure. None of the factors investigated so far showed however any influence of RPV clearance. Importantly, we have found that the standard daily dosage regimen (25 mg QD) proposed for rilpivirine results in concentrations below the proposed therapeutic target in about 40% of patients. In these conditions, virologie escape is a potential risk that remains to be further investigated, notably via the TDM approach that can be a useful tool to identify patients who are at risk for being exposed to less than optimal levels of rilpivirine in plasma. Besides the last generation NNRTI rilpivirine, we have studied efavirenz, the major NNRTI clinically used so far. Namely for efavirenz, we aimed at identifying a potential new marker of toxicity that may be incriminated for the neuropsychological sides effects and hence discontinuation of efavirenz therapy. To that endeavour, a comprehensive analysis of phase I and phase II metabolites profiles has been performed in plasma, CSF and in urine from patients under efavirenz therapy. We have found that phase II metabolites of EFV constitute the major species circulating in blood, sometimes exceeding the levels of the parent drug efavirenz. Moreover we have identified a new metabolite of efavirenz in humans, namely the 8-OH-EFV- sulfate which is present at high concentrations in all body compartments from patients under efavirenz therapy. These investigations may open the way to possible alternate phenotypic markers of efavirenz toxicity. Finally, the specific influence of P-glycoprotein on the cellular disposition of a series ARVs (NNRTIs and Pis] has been studies in in vitro cell systems using the siRNA silencing approach. -- Depuis l'introduction de la thérapie antirétrovirale (ARVs) la morbidité et la mortalité liées au VIH ont considérablement diminué. En parallèle le traitement contre le virus de l'hépatite C (VHC) a connu récemment d'énormes progrès avec l'arrivée de nouveaux médicaments puissants, ce qui a permis une augmentation considérable de la guérison de l'infection par le VHC. En dépit de l'efficacité de ces traitements antiviraux, les échecs thérapeutiques ainsi que les effets secondaires des traitements restent un problème important. Une réponse imparfaite ou la toxicité du traitement est certainement multifactorielle. Le suivi thérapeutique des médicaments [Therapeutic Drug Monitoring TDM) à travers la mesure des concentrations plasmatiques constitue une approche importante pour guider le traitement médicamenteux et de s'assurer que les patients sont exposés à des concentrations optimales des médicaments dans le sang, et puissent tirer tout le bénéfice potentiel du traitement. L'objectif global de cette thèse était d'étudier les facteurs pharmacocinétiques et pharmacogénétiques qui influencent l'exposition des médicaments antiviraux (ARVs et anti- VHC) récemment approuvés. A cet effet, des méthodes de quantification des concentrations plasmatiques des médicaments antirétroviraux, anti-VHC ainsi que pour certains métabolites ont été développées et validées en utilisant la Chromatographie liquide couplée à la spectrométrie de masse tandem. Ces méthodes ont été utilisées pour le TDM des ARVs et pour les agents anti-VHC chez les patients infectés par le VIH, et le VHC, respectivement, mais aussi chez les patients co-infectés par le VIH-VHC. Un modèle de pharmacocinétique de population a été développé pour caractériser la variabilité inter-et intra-patient du médicament rilpivirine, un inhibiteur non nucléosidique de la transcriptase de VIH et d'identifier les variables génétiques et non génétiques influençant l'exposition au médicament. Aucun des facteurs étudiés n'a montré d'influence notable sur la clairance de la rilpivirine. Toutefois, la concentration résiduelle extrapolée selon le modèle de pharmacocinétique de population qui a été développé, a montré qu'une grande proportion des patients présente des concentrations minimales inférieures à la cible thérapeutique proposée. Dans ce contexte, la relation entre les concentrations minimales et l'échappement virologique nécessite une surveillance étroite des taux sanguins des patients recevant de la rilpivirine. A cet effet, le suivi thérapeutique est un outil important pour l'identification des patients à risque soient sous-exposés à lai rilpivirine. Pour identifier de nouveaux marqueurs de la toxicité qui pourraient induire l'arrêt du traitement, le profil des métabolites de phase I et de phase II a été étudié dans différentes matrices [plasma, LCR et urine) provenant de patients recevant de l'efavirenz. Les métabolites de phase II, qui n'avaient à ce jour jamais été investigués, constituent les principales espèces présentes dans les matrices étudiées. Au cours de ces investigations, un nouveau métabolite 8- OH-EFV-sulfate a été identifié chez l'homme, et ce dernier est. présent à des concentrations importantes. L'influence de certains facteurs pharmacogénétique des patients sur le profil des métabolites a été étudiée et ouvre la voie à de possibles nouveaux marqueurs phénotypiques alternatifs qui pourraient possiblement mieux prédire la toxicité associée au traitement par l'efavirenz. Finalement, nous nous sommes intéressés à étudier dans un modèle in vitro certains facteurs, comme la P-glycoprotéine, qui influencent la disposition cellulaire de certains médicaments antirétroviraux, en utilisant l'approche par la technologie du siRNA permettant de bloquer sélectivement l'expression du gène de cette protéine d'efflux des médicaments. -- Depuis l'introduction de la thérapie antiretrovirale (ARVs] la morbidité et la mortalité liées au VIH ont considérablement diminué. En parallèle le traitement contre le virus de l'hépatite C (VHC) a connu récemment d'énormes progrès avec l'arrivée de nouveaux médicaments puissants, ce qui a permis une augmentation considérable de la guérison de l'infection par le VHC. En dépit de l'efficacité de ces traitements antiviraux, les échecs thérapeutiques ainsi que les effets secondaires des traitements restent un problème important. Il a pu être démontré que la concentration de médicament présente dans l'organisme est corrélée avec l'efficacité clinique pour la plupart des médicaments agissant contre le VIH et contre le VHC. Les médicaments antiviraux sont généralement donnés à une posologie fixe et standardisée, à tous les patients, il existe cependant une importante variabilité entre les concentrations sanguines mesurées chez les individus. Cette variabilité peut être expliquée par plusieurs facteurs démographiques, environnementaux ou génétiques. Dans ce contexte, le suivi des concentrations sanguines (ou Therapeutic Drug Monitoring, TDM) permet de contrôler que les patients soient exposés à des concentrations suffisantes (pour bloquer la réplication du virus dans l'organisme) et éviter des concentrations excessives, ce qui peut entraîner l'apparition d'intolérence au traitement. Le but de ce travail de thèse est d'améliorer la compréhension des facteurs pharmacologiques et génétiques qui peuvent influencer l'efficacité et/ou la toxicité des médicaments antiviraux, dans le but d'améliorer le suivi des patients. A cet effet, des méthodes de dosage très sensibles et ont été mises au point pour permettre de quantifier les médicaments antiviraux dans le sang et dans d'autres liquides biologiques. Ces méthodes de dosage sont maintenant utilisées d'une part dans le cadre de la prise en charge des patients en routine et d'autre part pour diverses études cliniques chez les patients infectés soit par le HIV, le HCV ou bien coinfectés par les deux virus. Une partie de ce travail a été consacrée à l'investigation des différents facteurs démographiques, génétiques et environnementaux qui pourraient l'influencer la réponse clinique à la rilpivirine, un nouveau médicament contre le VIH. Toutefois, parmi tous les facteurs étudiés à ce jour, aucun n'a permis d'expliquer la variabilité de l'exposition à la rilpivirine chez les patients. On a pu cependant observer qu'à la posologie standard recommandée, un pourcentage relativement élevé de patients pourrait présenter des concentrations inférieures à la concentration sanguine minimale actuellement proposée. Il est donc utile de surveiller étroitement les concentrations de rilpivirine chez les patients pour identifier sans délai ceux qui risquent d'être sous-exposés. Dans l'organisme, le médicament subit diverses transformations (métabolisme) par des enzymes, notamment dans le foie, il est transporté dans les cellules et tissus par des protéines qui modulent sa concentration au site de son action pharmacologique. A cet effet, différents composés (métabolites) produits dans l'organisme après l'administration d'efavirenz, un autre médicament anti-VIH, ont été étudiés. En conclusion, nous nous sommes intéressés à la fois aux facteurs pharmacologiques et génétiques des traitements antiviraux, une approche qui s'inscrit dans l'optique d'une stratégie globale de prise en charge du patient. Dans ce contexte, le suivi des concentrations sanguines de médicaments constitue une des facettes du domaine émergent de la Médecine Personnalisée qui vise à maximiser le bénéfice thérapeutique et le profil de tolérance des médicaments antiviraux

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Imatinib trough plasma concentrations (Cmin) have been correlated with treatment response in chronic myeloid leukemia (CML) patients. The use of Cmin monitoring for optimizing imatinib dosage (therapeutic drug monitoring [TDM]) is therefore proposed for patients with unsatisfying response or tolerance ("rescue TDM"). A cycle of "routine TDM" for dosage individualization could also be beneficial to prevent unfavorable events, yet its clinical usefulness has not been evaluated. We aimed to assess prospectively whether a "routine TDM" intervention targeting imatinib Cmin of 1000 ng/mL (tolerance, 750-1500 ng/mL) could improve efficacy, tolerance, and persistence on treatment compared with "rescue TDM" use only. Patients (or Materials) and Methods: The Swiss Imatinib COncentration Monitoring Evaluation (I-COME) study was a multicenter randomized controlled trial (ISRCTN31181395). Adult patients in chronic or accelerated phase CML receiving imatinib ≤5 years were eligible. Patients were randomly (1:1) allocated to receive "routine TDM" intervention or to serve as controls with access only to "rescue TDM". All had 1-year follow-up. The primary endpoint was a combined efficacy-safety outcome (failure- and toxicity-free survival without imatinib discontinuation), analyzed in intention-to-treat. Results: Among 56 CML recruited patients, 55 had their molecular and cytogenetic response measured. 14/27 of patients receiving "routine TDM" (52% [33%-71%]) remained event-free versus 16/28 of control patients with "rescue TDM" only (57% [39%-75%]; P=0.69). In the "routine TDM" group, dosage recommendations were adopted entirely in 50% of patients (median Cmin at study end, 895 ng/mL; CV = 33%). These patients had fewer unfavorable events (28% [5%-52%]) compared with patients not receiving the advised dosage (77% [54%-99%]; P = 0.03; median Cmin at study end, 648 ng/mL; CV = 38%). Conclusion: This first prospective target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" of imatinib, especially due to a small patient number and limited prescriber's adherence to dosage recommendations. Nevertheless, the patients receiving the advised dosage more often met target concentrations and the combined outcome (efficacy, tolerance, and persistence). A cycle of routine TDM could thus be favorable, at least in patients eligible for dosage adjustment. Its usefulness should, however, be further confirmed in larger trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Machine learning has been largely applied to analyze data in various domains, but it is still new to personalized medicine, especially dose individualization. In this paper, we focus on the prediction of drug concentrations using Support Vector Machines (S VM) and the analysis of the influence of each feature to the prediction results. Our study shows that SVM-based approaches achieve similar prediction results compared with pharmacokinetic model. The two proposed example-based SVM methods demonstrate that the individual features help to increase the accuracy in the predictions of drug concentration with a reduced library of training data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modeling concentration-response function became extremely popular in ecotoxicology during the last decade. Indeed, modeling allows determining the total response pattern of a given substance. However, reliable modeling is consuming in term of data, which is in contradiction with the current trend in ecotoxicology, which aims to reduce, for cost and ethical reasons, the number of data produced during an experiment. It is therefore crucial to determine experimental design in a cost-effective manner. In this paper, we propose to use the theory of locally D-optimal designs to determine the set of concentrations to be tested so that the parameters of the concentration-response function can be estimated with high precision. We illustrated this approach by determining the locally D-optimal designs to estimate the toxicity of the herbicide dinoseb on daphnids and algae. The results show that the number of concentrations to be tested is often equal to the number of parameters and often related to the their meaning, i.e. they are located close to the parameters. Furthermore, the results show that the locally D-optimal design often has the minimal number of support points and is not much sensitive to small changes in nominal values of the parameters. In order to reduce the experimental cost and the use of test organisms, especially in case of long-term studies, reliable nominal values may therefore be fixed based on prior knowledge and literature research instead of on preliminary experiments

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Imipenem plasma-concentrations were measured in 19 critically-ill children (median 0.8 year, range 0.02-12.9 years). Wide inter-individual variations (2-4x at peak and >10x at through concentrations) resulted in unpredictable plasma-levels in several children. To avoid subtherapeutic drug levels we recommend at least 100 mg/kg/day of imipenem-cilastatin in critically-ill children requiring such therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèseLe syndrome d'apnées obstructives du sommeil (SAOS) est une pathologie respiratoire fréquente. Sa prévalence est estimée entre 2 et 5% de la population adulte générale. Ses conséquences sont importantes. Notamment, une somnolence diurne, des troubles de la concentration, des troubles de la mémoire et une augmentation du risque d'accident de la route et du travail. Il représente également un facteur de risque cardiovasculaire indépendant.Ce syndrome est caractérisé par la survenue durant le sommeil d'obstructions répétées des voies aériennes supérieures. L'arrêt ou la diminution d'apport en oxygène vers les poumons entraîne des épisodes de diminution de la saturation en oxygène de l'hémoglobine. Les efforts ventilatoires visant à lever l'obstacle présent sur les voies aériennes causent de fréquents réveils à l'origine d'une fragmentation du sommeil.La polysomnographie (PSG) représente le moyen diagnostic de choix. Il consiste en l'enregistrement dans un laboratoire du sommeil et en présence d'un technicien diplômé, du tracé électroencéphalographique (EEG), de l'électrooculogramme (EOG), de l'électromyogramme mentonnier (EMG), du flux respiratoire nasal, de l'oxymétrie de pouls, de la fréquence cardiaque, de l'électrocardiogramme (ECG), des mouvements thoraciques et abdominaux, de la position du corps et des mouvements des jambes. L'examen est filmé par caméra infrarouge et les sons sont enregistrés.Cet examen permet entre autres mesures, de déterminer les événements respiratoires obstructifs nécessaires au diagnostic de syndrome d'apnée du sommeil. On définit une apnée lors d'arrêt complet du débit aérien durant au moins 10 secondes et une hypopnée en cas, soit de diminution franche de l'amplitude du flux respiratoire supérieure à 50% durant au moins 10 secondes, soit de diminution significative (20%) de l'amplitude du flux respiratoire pendant au minimum 10 secondes associée à un micro-éveil ou à une désaturation d'au moins 3% par rapport à la ligne de base. La détection des micro-éveils se fait en utilisant les dérivations électroencéphalographiques, électromyographiques et électrooculographiques. Il existe des critères visuels de reconnaissance de ces éveils transitoire: apparition de rythme alpha (8.1 à 12.0 Hz) ou beta (16 à 30 Hz) d'une durée supérieure à 3 secondes [20-21].Le diagnostic de S AOS est retenu si l'on retrouve plus de 5 événements respiratoires obstructifs par heure de sommeil associés soit à une somnolence diurne évaluée selon le score d'Epworth ou à au moins 2 symptômes parmi les suivants: sommeil non réparateur, étouffements nocturne, éveils multiples, fatigue, troubles de la concentration. Le S AOS est gradué en fonction du nombre d'événements obstructifs par heure de sommeil en léger (5 à 15), modéré (15 à 30) et sévère (>30).La polysomnographie (PSG) comporte plusieurs inconvénients pratiques. En effet, elle doit être réalisée dans un laboratoire du sommeil avec la présence permanente d'un technicien, limitant ainsi son accessibilité et entraînant des délais diagnostiques et thérapeutiques. Pour ces mêmes raisons, il s'agit d'un examen onéreux.La polygraphie respiratoire (PG) représente l'alternative diagnostique au gold standard qu'est l'examen polysomnographique. Cet examen consiste en l'enregistrement en ambulatoire, à savoir au domicile du patient, du flux nasalrespiratoire, de l'oxymétrie de pouls, de la fréquence cardiaque, de la position du corps et du ronflement (par mesure de pression).En raison de sa sensibilité et sa spécificité moindre, la PG reste recommandée uniquement en cas de forte probabilité de SAOS. Il existe deux raisons principales à l'origine de la moindre sensibilité de l'examen polygraphique. D'une part, du fait que l'état de veille ou de sommeil n'est pas déterminé avec précision, il y a dilution des événements respiratoires sur l'ensemble de l'enregistrement et non sur la période de sommeil uniquement. D'autre part, en l'absence de tracé EEG, la quantification des micro-éveils est impossible. Il n'est donc pas possible dans l'examen poly graphique, de reconnaître une hypopnée en cas de diminution de flux respiratoire de 20 à 50% non associée à un épisode de désaturation de l'hémoglobine de 3% au moins. Alors que dans l'examen polysomnographique, une telle diminution du flux respiratoire pourrait être associée à un micro-éveil et ainsi comptabilisée en tant qu'hypopnée.De ce constat est né la volonté de trouver un équivalent de micro-éveil en polygraphie, en utilisant les signaux à disposition, afin d'augmenter la sensibilité de l'examen polygraphique.Or plusieurs études ont démontrés que les micro-éveils sont associés à des réactions du système nerveux autonome. Lors des micro-éveils, on met en évidence la survenue d'une vasoconstriction périphérique. La variation du tonus sympathique associée aux micro-éveils peut être mesurée par différentes méthodes. Les variations de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie représentant un marqueur fiable de la vasoconstriction périphérique associée aux micro-réveils, il paraît donc opportun d'utiliser ce marqueur autonomique disponible sur le tracé des polygraphies ambulatoires afin de renforcer la sensibilité de cet examen.Le but de l'étude est d'évaluer la sensibilité des variations de l'amplitude de l'onde de pouls pour détecter des micro-réveils corticaux afin de trouver un moyen d'augmenter la sensibilité de l'examen polygraphique et de renforcer ainsi sont pouvoir diagnostic.L'objectif est de démontrer qu'une diminution significative de l'amplitude de l'onde pouls est concomitante à une activation corticale correspondant à un micro¬réveil. Cette constatation pourrait permettre de déterminer une hypopnée, en polygraphie, par une diminution de 20 à 50% du flux respiratoire sans désaturation de 3% mais associée à une baisse significative de l'amplitude de pouls en postulant que l'événement respiratoire a entraîné un micro-réveil. On retrouve par cette méthode les mêmes critères de scoring d'événements respiratoires en polygraphie et en polysomnographie, et l'on renforce la sensibilité de la polygraphie par rapport au gold standard polysomnographique.La méthode consiste à montrer en polysomnographie qu'une diminution significative de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie est associée à une activation du signal électroencéphalographique, en réalisant une analyse spectrale du tracé EEG lors des baisses d'amplitude du signal d'onde de pouls.Pour ce faire nous avons réalisé une étude rétrospective sur plus de 1000 diminutions de l'amplitude de l'onde de pouls sur les tracés de 10 sujets choisis de manière aléatoire parmi les patients référés dans notre centre du sommeil (CIRS) pour suspicion de trouble respiratoire du sommeil avec somnolence ou symptomatologie diurne.Les enregistrements nocturnes ont été effectués de manière standard dans des chambres individuelles en utilisant le système d'acquisition Embla avec l'ensemble des capteurs habituels. Les données ont été par la suite visuellement analysées et mesurées en utilisant le software Somnologica version 5.1, qui fournit un signal de l'amplitude de l'onde de pouls (puise wave amplitude - PWA).Dans un premier temps, un technicien du sommeil a réalisé une analyse visuelle du tracé EEG, en l'absence des données du signal d'amplitude d'onde de pouls. Il a déterminé les phases d'éveil et de sommeil, les stades du sommeil et les micro¬éveils selon les critères standards. Les micro-éveils sont définis lors d'un changement abrupt dans la fréquence de l'EEG avec un pattern d'ondes thêta-alpha et/ou une fréquence supérieure à 16 Hz (en l'absence de fuseau) d'une durée d'au minimum trois secondes. Si cette durée excède quinze secondes, l'événement correspond à un réveil.Puis, deux investigateurs ont analysé le signal d'amplitude d'onde de pouls, en masquant les données du tracé EEG qui inclut les micro-éveils. L'amplitude d'onde de pouls est calculée comme la différence de valeur entre le zénith et le nadir de l'onde pour chaque cycle cardiaque. Pour chaque baisse de l'amplitude d'onde de pouls, la plus grande et la plus petite amplitude sont déterminées et le pourcentage de baisse est calculé comme le rapport entre ces deux amplitudes. On retient de manière arbitraire une baisse d'au moins 20% comme étant significative. Cette limite a été choisie pour des raisons pratiques et cliniques, dès lors qu'elle représentait, à notre sens, la baisse minimale identifiable à l'inspection visuelle. Chaque baisse de PWA retenue est divisée en 5 périodes contiguës de cinq secondes chacune. Deux avant, une pendant et deux après la baisse de PWA.Pour chaque période de cinq secondes, on a pratiqué une analyse spectrale du tracé EEG correspondant. Le canal EEG C4-A1 est analysé en utilisant la transformée rapide de Fourier (FFT) pour chaque baisse de PWA et pour chaque période de cinq secondes avec une résolution de 0.2 Hz. La distribution spectrale est catégorisée dans chaque bande de fréquence: delta (0.5 à 4.0 Hz); thêta (4.1 à 8.0Hz); alpha (8.1 à 12.0 Hz); sigma (12.1 à 16 Hz) et beta (16.1 à 30.0 Hz). La densité de puissance (power density, en μΥ2 ) pour chaque bande de fréquence a été calculée et normalisée en tant que pourcentage de la puissance totale. On a déterminé, ensuite, la différence de densité de puissance entre les 5 périodes par ANOVA on the rank. Un test post hoc Tukey est été utilisé pour déterminer si les différences de densité de puissance étaient significatives. Les calculs ont été effectués à l'aide du software Sigmastat version 3.0 (Systat Software San Jose, California, USA).Le principal résultat obtenu dans cette étude est d'avoir montré une augmentation significative de la densité de puissance de l'EEG pour toutes les bandes de fréquence durant la baisse de l'amplitude de l'onde de pouls par rapport à la période avant et après la baisse. Cette augmentation est par ailleurs retrouvée dans la plupart des bande de fréquence en l'absence de micro-réveil visuellement identifié.Ce résultat témoigné donc d'une activation corticale significative associée à la diminution de l'onde de pouls. Ce résulat pourrait permettre d'utiliser les variations de l'onde de pouls dans les tracés de polygraphie comme marqueur d'une activation corticale. Cependant on peut dire que ce marqueur est plus sensible que l'analyse visuelle du tracé EEG par un technicien puisque qu'on notait une augmentation de lactivité corticale y compris en l'absence de micro-réveil visuellement identifié. L'application pratique de ces résultats nécessite donc une étude prospective complémentaire.