160 resultados para COINCIDENCE MEASUREMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ 15N by elemental analysis (EA)-isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ 15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2-two ammonium sulphates [(NH4)2SO4]-and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ 15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of 3-beta-hydroxybutyrate (3HB) in blood and two liver samples were retrospectively examined in a series of medicolegal autopsies. These cases included diabetic ketoacidosis, nondiabetic individuals presenting moderate to severe decompositional changes and nondiabetic medicolegal cases privy of decompositional changes. 3HB concentrations in liver sample homogenates correlate well with blood values in all examined groups. Additionally, decompositional changes were not associated with increases in blood and liver 3HB levels. These results suggest that 3HB can be reliably measured in liver homogenates when blood is not available at autopsy. Furthermore, they suggest that metabolic disturbances potentially leading or contributing to death may be objectified through liver 3HB determination even in decomposed bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine methadone plasma trough and peak concentrations in patients presenting opiate withdrawal symptoms after introduction of nevirapine or efavirenz. To describe the disappearance of these symptoms after methadone titration based on plasma concentrations rather than on the symptoms. Methods: Nine patients undergoing highly active antiretroviral therapy (HAART) and either nevirapine or efavirenz treatment were monitored daily for opiate withdrawal in a specialized drug addiction center. Methadone dose was titrated daily, and plasma concentrations were measured. The data are retrospective (case series). Results: Several patients complained of symptoms such as nausea, vomiting, accelerated intestinal transit, or insomnia. Even after methadone titration based on clinical symptoms, patients and health-care providers trained in infectious disease did not classify these as withdrawal symptoms and considered them as the side effects of HAART or anxiety. Methadone plasma trough concentration showed low levels of (R)- and (R,S)-methadone. Further methadone dose adjustment according to plasma level resulted in the disappearance of these withdrawal symptoms. The daily methadone dose was split when the peak/trough (R)-methadone ratio was more than 2. Conclusions: When introducing efavirenz or nevirapine to patients undergoing methadone treatment, withdrawal symptoms should be monitored, especially those such as insomnia, vomiting, or nausea. Methadone plasma trough and peak measurements can be of value in preventing unnecessary side effects of HAART.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information. Whereas activity assays measure only active renin, immunoassays measure both active and inhibited renin. Particular care must be taken in the collection and processing of blood samples and in the performance of these assays to avoid errors in renin measurement. Both activity assays and immunoassays are susceptible to renin overestimation due to prorenin activation. In addition, activity assays performed with peptidase inhibitors may overestimate the degree of inhibition of PRA by renin inhibitor therapy. Moreover, immunoassays may overestimate the reactive increase in plasma renin concentration in response to renin inhibitor therapy, owing to the inhibitor promoting conversion of prorenin to an open conformation that is recognized by renin immunoassays. CONCLUSIONS: The successful application of renin assays to patient care requires that the clinician and the clinical chemist understand the information provided by these assays and of the precautions necessary to ensure their accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.