157 resultados para vacuum aspiratory technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La pose d'un cathéter veineux central peut se faire par plusieurs abords. La connaissance de l'anatomie, du matériel, la maîtrise des détails de la procédure pour chaque type d'abord et une attention particulière à l'asepsie sont des prérequis importants pour limiter les risques de complications et pour donner une information complète et exhaustive au patient. Cet article peut être utilisé comme base pour le développement d'une check-list, utile pour les médecins qui doivent procéder à la pose d'un cathéter veineux central mais qui ne possèdent pas encore une maîtrise du geste. Several approaches exist for central vein catheterization. Mastery of the various steps of this procedure and understanding of the basics of asepsis are critical to prevent any complication. They also built the basis for an exhaustive communication with the patient, to obtain an informed consent. This article can in addition be used to develop a checklist in order to (self-)assess competence in procedural skills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of co-expression and linkage of distinct T-DNAs present in separate Agrobacterium tumefaciens was analysed in Arabidopsis thaliana transformed by the vacuum infiltration method. Co-expression was monitored by the synthesis of three bacterial proteins involved in the production of polyhydroxybutyrate (PHB) in the plastids. Out of 80 kanamycin-resistant transgenic plants analysed, 13 plants were co-transformed with the two distinct T-DNAs and produced PHB. Of those, 7 lines had a kanamycin-resistance segregation ratio consistent with the presence of a single functional insert. Genetic linkage between the distinct T-DNAs was demonstrated for all 13 PHB-producing lines, while physical linkage between the distinct T-DNAs was shown for 12 out of 13 lines. T-DNAs were frequently linked in an inverted orientation about the left borders. Transformation of A. thaliana by the co-infiltration of two A. tumefaciens containing distinct T-DNAs is, thus, an efficient approach for the integration and expression of several transgenes at a single locus. This approach will facilitate the creation and study of novel metabolic pathways requiring the expression of numerous transgenes.

Relevância:

20.00% 20.00%

Publicador: