195 resultados para Symbolism in medicine.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To assess the importance of spirituality and religious coping among outpatients with a DSM-IV diagnosis of schizophrenia or schizoaffective disorder living in three countries. Method: A total of 276 outpatients (92 from Geneva, Switzerland, 121 from Trois-Rivières, Canada, and 63 from Durham, North Carolina), aged 18-65, were administered a semi-structured interview on the role of spirituality and religiousness in their lives and to cope with their illness. Results: Religion is important for outpatients in each of the three country sites, and religious involvement is higher than in the general population. Religion was helpful (i.e., provided a positive sense of self and positive coping with the illness) among 87% of the participants and harmful (a source of despair and suffering) among 13%. Helpful religion was associated with better social, clinical and psychological status. The opposite was observed for the harmful aspects of religion. In addition, religion sometimes conflicted with psychiatric treatment. Conclusions: These results indicate that outpatients with schizophrenia or schizoaffective disorder often use spirituality and religion to cope with their illness, basically positively, yet sometimes negatively. These results underscore the importance of clinicians taking into account the spiritual and religious lives of patients with schizophrenia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Differences in physico-chemical characteristics of bone grafts to fill bone defects have been demonstrated to influence in vitro bacterial biofilm formation. Aim of the study was to investigate in vivo staphylococcal biofilm formation on different calcium phosphate bone substitutes. A foreign-body guinea-pig infection model was used. Teflon cages prefilled with β-tricalcium phosphate, calcium-deficient hydroxyapatite, or dicalcium phosphate (DCP) scaffold were implanted subcutaneously. Scaffolds were infected with 2 × 10(3) colony-forming unit of Staphylococcus aureus (two strains) or S. epidermidis and explanted after 3, 24 or 72 h of biofilm formation. Quantitative and qualitative biofilm analysis was performed by sonication followed by viable counts, and microcalorimetry, respectively. Independently of the material, S. aureus formed increasing amounts of biofilm on the surface of all scaffolds over time as determined by both methods. For S. epidermidis, the biofilm amount decreased over time, and no biofilm was detected by microcalorimetry on the DCP scaffolds after 72 h of infection. However, when using a higher S. epidermidis inoculum, increasing amounts of biofilm were formed on all scaffolds as determined by microcalorimetry. No significant variation in staphylococcal in vivo biofilm formation was observed between the different materials tested. This study highlights the importance of in vivo studies, in addition to in vitro studies, when investigating biofilm formation of bone grafts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Proton T1 relaxation times of metabolites in the human brain have not previously been published at 7 T. In this study, T1 values of CH3 and CH2 group of N-acetylaspartate and total creatine as well as nine other brain metabolites were measured in occipital white matter and gray matter at 7 T using an inversion-recovery technique combined with a newly implemented semi-adiabatic spin-echo full-intensity acquired localized spectroscopy sequence (echo time = 12 ms). The mean T1 values of metabolites in occipital white matter and gray matter ranged from 0.9 to 2.2 s. Among them, the T1 of glutathione, scyllo-inositol, taurine, phosphorylethanolamine, and N-acetylaspartylglutamate were determined for the first time in the human brain. Significant differences in T1 between white matter and gray matter were found for water (-28%), total choline (-14%), N-acetylaspartylglutamate (-29%), N-acetylaspartate (+4%), and glutamate (+8%). An increasing trend in T1 was observed when compared with previously reported values of N-acetylaspartate (CH3 ), total creatine (CH3 ), and total choline at 3 T. However, for N-acetylaspartate (CH3 ), total creatine, and total choline, no substantial differences compared to previously reported values at 9.4 T were discernible. The T1 values reported here will be useful for the quantification of metabolites and signal-to-noise optimization in human brain at 7 T. Magn Reson Med 69:931-936, 2013. © 2012 Wiley Periodicals, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: A pregnant woman was referred for post-operative radiotherapy of a malignant schwannoma in the head and neck region. A best-treatment plan was devised in order to minimize the fetal dose. MATERIAL AND METHODS: The fetal dose resulting from radiological examinations was determined according to international protocols, that resulting from radiotherapy was calculated according to Recommendation 36 of the American Association of Physicists in Medicine (AAPM) Task Group. Pre-treatment dosimetry was performed with an anthropomorphic phantom. Several alternative treatment plans were evaluated. The use of a multileaf collimator (MLC) and a virtual wedge (VW) was compared to cerrobend blocks (CB) and physical wedge (PW). In-vivo dosimetry was performed using a vaginal probe containing thermoluminescent dosimeters (TLD). RESULTS: The total fetal dose resulting from diagnostic and radiotherapy procedures was estimated to be 36 mGy. The technique based on MLC and VW was elected for patient treatment. Measurements for this configuration resulted in afetal dose reduction of 82%. The shielding of the patient's abdomen further reduced the fetal dose by 42%. CONCLUSION: The use of VW and MLC for the treatment of a pregnant woman is highly recommended. Each case should be individually studied with pre-treatment and in-vivo dosimetry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stimulated echoes are widely used for imaging functional tissue parameters such as diffusion coefficient, perfusion, and flow rates. They are potentially interesting for the assessment of various cardiac functions. However, severe limitations of the stimulated echo acquisition mode occur, which are related to the special dynamic properties of the beating heart and flowing blood. To the well-known signal decay due to longitudinal relaxation and through-plane motion between the preparation and the read-out period of the stimulated echoes, additional signal loss is often observed. As the prepared magnetization is fixed with respect to the tissue, this signal loss is caused by the tissue deformation during the cardiac cycle, which leads to a modification of the modulation frequency of the magnetization. These effects are theoretically derived and corroborated by phantom and in vivo experiments.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The time constant of cerebral arterial bed (in brief time constant) is a product of brain arterial compliance (C(a)) and resistance (CVR). We tested the hypothesis that in normal subjects, changes in end-tidal CO(2) (EtCO(2)) affect the value of the time constant. C(a) and CVR were estimated using mathematical transformations of arterial pressure (ABP) and transcranial Doppler (TCD) cerebral blood flow velocity waveforms. Responses of the time constant to controlled changes in EtCO(2) were compared in 34 young volunteers. Hypercapnia shortened the time constant (0.22 s [0.17, 0.26] vs. 0.16 s [0.13, 0.20]; p = 0.000001), while hypocapnia lengthened the time constant (0.22 s [0.17, 0.26] vs. 0.23 s [0.19, 0.32]; p < 0.0032). The time constant was negatively correlated with changes in EtCO(2) (R(partial) = -0.68, p < 0.000001). This was associated with a decrease in CVR when EtCO(2) increased (R(partial) = -0.80, p < 0.000001) and C(a) remained independent of changes in EtCO(2). C(a) was negatively correlated with mean ABP (R(partial) = -0.68, p < 0.000001). In summary, the time constant shortens with increasing EtCO(2). Its potential role in cerebrovascular investigations needs further studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In vivo localized and fully adiabatic homonuclear and heteronuclear polarization transfer experiments were designed and performed in the rat brain at 9.4 T after infusion of hyperpolarized sodium [1,2-(13)C(2)] and sodium [1-(13)C] acetate. The method presented herein leads to highly enhanced in vivo detection of short-T(1) (13)C as well as attached protons. This indirect detection scheme allows for probing additional molecular sites in hyperpolarized substrates and their metabolites and can thus lead to improved spectral resolution such as in the case of (13)C-acetate metabolism.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Quantification of short-echo time proton magnetic resonance spectroscopy results in >18 metabolite concentrations (neurochemical profile). Their quantification accuracy depends on the assessment of the contribution of macromolecule (MM) resonances, previously experimentally achieved by exploiting the several fold difference in T(1). To minimize effects of heterogeneities in metabolites T(1), the aim of the study was to assess MM signal contributions by combining inversion recovery (IR) and diffusion-weighted proton spectroscopy at high-magnetic field (14.1 T) and short echo time (= 8 msec) in the rat brain. IR combined with diffusion weighting experiments (with δ/Δ = 1.5/200 msec and b-value = 11.8 msec/μm(2)) showed that the metabolite nulled spectrum (inversion time = 740 msec) was affected by residuals attributed to creatine, inositol, taurine, choline, N-acetylaspartate as well as glutamine and glutamate. While the metabolite residuals were significantly attenuated by 50%, the MM signals were almost not affected (< 8%). The combination of metabolite-nulled IR spectra with diffusion weighting allows a specific characterization of MM resonances with minimal metabolite signal contributions and is expected to lead to a more precise quantification of the neurochemical profile.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI pulse sequence in a single short breathhold. The method was validated against conventional inversion-recovery (IR) DE images for identifying regions of myocardial infarction (MI). The method was based on the acquisition of three consecutive images of the same anatomical slice. One image has T(1)-weighted contrast in which infarction appears bright. The two other images are used to construct an anatomical image of the heart, which is combined with the first image to produce a black-blood viability image. However, using appropriate modulation and demodulation frequencies, the latter two images bear useful information about myocardial deformation that results in a cardiac strain-encoding (SENC) functional image. In this work, a method is proposed for obtaining three consecutive SENC images in a single acquisition that can be combined to produce a composite image of the heart, which shows both functional and viability information. The proposed technique reduces scan time by one-half, compared with separate acquisitions of functional and viability images, and alleviates misregistration problems caused by separate breathholds.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In studies of the natural history of HIV-1 infection, the time scale of primary interest is the time since infection. Unfortunately, this time is very often unknown for HIV infection and using the follow-up time instead of the time since infection is likely to provide biased results because of onset confounding. Laboratory markers such as the CD4 T-cell count carry important information concerning disease progression and can be used to predict the unknown date of infection. Previous work on this topic has made use of only one CD4 measurement or based the imputation on incident patients only. However, because of considerable intrinsic variability in CD4 levels and because incident cases are different from prevalent cases, back calculation based on only one CD4 determination per person or on characteristics of the incident sub-cohort may provide unreliable results. Therefore, we propose a methodology based on the repeated individual CD4 T-cells marker measurements that use both incident and prevalent cases to impute the unknown date of infection. Our approach uses joint modelling of the time since infection, the CD4 time path and the drop-out process. This methodology has been applied to estimate the CD4 slope and impute the unknown date of infection in HIV patients from the Swiss HIV Cohort Study. A procedure based on the comparison of different slope estimates is proposed to assess the goodness of fit of the imputation. Results of simulation studies indicated that the imputation procedure worked well, despite the intrinsic high volatility of the CD4 marker.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.