42 resultados para SMA wire actuator


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: We have developed a nonviral gene therapy method based on the electrotransfer of plasmid in the ciliary muscle. These easily accessible smooth muscle cells could be turned into a biofactory for any therapeutic proteins to be secreted in a sustained manner in the ocular media. METHODS: Electrical conditions, design of electrodes, plasmid formulation, method and number of injections were optimized in vivo in the rat by localizing β-galactosidase expression and quantifying reporter (luciferase) and therapeutic (anti-tumor necrosis factor) proteins secretion in the ocular media. Anatomical measurements were performed via human magnetic resonance imaging to design a human eye-sized prototype that was tested in the rabbit. RESULTS: In the rat, transscleral injection of 30 µg of plasmid diluted in half saline (77 mM NaCl) followed by application of eight square-wave electrical pulses (15 V, 10 ms, 5.3 Hz) using two platinum/iridium electrodes, an internal wire and an external sheet, delivered plasmid efficiently to the ciliary muscle fibers. Gene transfer resulted in a long-lasting (at least 5 months) and plasmid dose-/injection number- dependent secretion of different molecular weight proteins mainly in the vitreous, without any systemic exposure. Because ciliary muscle anatomical measurements remained constant among ages in adult humans, an integrated device comprising needle-electrodes was designed and manufactured. Its usefulness was validated in the rabbit. CONCLUSIONS: Plasmid electrotransfer to the ciliary muscle with a suitable medical device represents a promising local and sustained protein delivery system for treating posterior segment diseases, avoiding repeated intraocular injections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We assessed by immunohistochemistry the expression of the phosphorylated (activated) form of Smad1 and 5 (P-SMAD1/5), of Noggin and of two smooth muscle cell markers (α-SMA and SM22) in a series of human myometrium samples and in a smooth muscle cell line derived from human myometrium (HUt-SMC, PromoCell, USA). Myometrium samples were removed from two cadavers (a fetus at 26weeks of gestation and a neonate) and from ten non-menopausal women who underwent hysterectomy for adenomyosis and leiomyoma. P-SMAD1/5 expression was never detected in myometrium (both normal and pathological specimens), but only as a nuclear positive staining in glandular and luminal epithelial cells in sections in which also the endometrial mucosa was present. Noggin was strongly expressed especially in myometrium and adenomyosis samples from non-menopausal patients in comparison to the neonatal and fetal myometrium specimens in which muscle cells were less positive. In more than 95% of HUt-SMCs, α-SMA and Desmin were co-expressed, indicating a pure smooth muscle phenotype. When progesterone was added to the culture medium, no P-SMAD1/5 expression was detected, whereas the expression Noggin and SM22, a marker of differentiated smooth muscle cells, increased by 3 fold (p=0.002) and 4.3 fold (p=0.001), respectively (p=0.002). Our results suggest that, in non-menopausal normal human myometrium, the BMP pathway might be inhibited and that this inhibition might be enhanced by progesterone, which increases the differentiation of smooth muscle cells (SM22 levels). These findings could help in the identification of new mechanisms that regulate uterine motility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An Adobe (R) animation is presented for use in undergraduate Biochemistry courses, illustrating the mechanism of Na+ and K+ translocation coupled to ATP hydrolysis by the (Na, K)-ATPase, a P-2c-type ATPase, or ATP-powered ion pump that actively translocates cations across plasma membranes. The enzyme is also known as an E-1/E-2-ATPase as it undergoes conformational changes between the E-1 and E-2 forms during the pumping cycle, altering the affinity and accessibility of the transmembrane ion-binding sites. The animation is based on Horisberger's scheme that incorporates the most recent significant findings to have improved our understanding of the (Na, K)-ATPase structure function relationship. The movements of the various domains within the (Na, K)-ATPase alpha-subunit illustrate the conformational changes that occur during Na+ and K+ translocation across the membrane and emphasize involvement of the actuator, nucleotide, and phosphorylation domains, that is, the "core engine" of the pump, with respect to ATP binding, cation transport, and ADP and P-i release.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Endoscopic mucosal resection (EMR) is an appealing method for treating intramucosal esophageal cancer but must comply with the following stringent requirements: proper preoperative staging, complete resection of the lesion, obtaining a resected specimen for histologic analysis of safety margins, and squamous reepithelialization without stricture formation. Methods: A rigid esophagoscope was created to resect up to 12 cm(2) of esophageal mucosa in a single specimen and at a constant depth through the submucosa. Under visual control, the esophageal mucosa is sucked into a transparent window and resected with a thin diathermy wire loop in 10 seconds. After extensive preclinical studies in a sheep model, this article reports our early experience in humans. Results: Twenty-one hemi-circumferential EMRs were performed for 11 dysplastic Barrett's esophagi and 10 early squamous cell carcinomas with no perforation, one hemorrhage controlled by embolization of the left gastric artery, and one incomplete resection. Deep safety margins were clear in 19 of 21 resected specimens (2 patients, unfit for operations, had submucosal invasion of squamous cell carcinoma and adenocarcinoma, respectively). Lateral margins were not clear by definition in 7 circumferential Barrett's esophagi, but were clear in 4 incomplete Barrett's esophagi and 10 early squamous cell carcinomas. Conclusions: Large EMRs of 12 cm(2) can safely be performed at the submucosal level in the esophagus. Although feasible in one session, circumferential EMR in humans is not yet advisable because of the risk of stricture formation during the healing phase. The rate of complications of this series of 21 EMRs in humans is acceptable. (Ann Thorac Surg 2010; 89: S2151-5) (C) 2010 by The Society of Thoracic Surgeons

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Between 1995 and 2005, the number of aortic aneurysms treated annually using endovascular techniques (EVAR) increased from 0 to 50, including all aortic stages. Our organization includes a large team of surgeons, a stock of three complete families of endoprostheses (straight, conical and bifurcated), a mobile trolley with accessories (arterial introducer/introducer sheath, guide wire, catheters, balloons, etc.) and an appliance on wheels for intravascular ultrasound examination (IVUS). This appliance, together with a mobile fluoroscopy device (c-arm), allows endovascular aneurysms analysis of every operating room in our institution, usually without angiography or the use of contrast medium. In general, we are therefore not depending on substantial preoperative imaging in order to identify candidates for endovascular aneurysms repair and can treat abdominal and thoracic aortic ruptures without delay. For endovascular aortic aneurysms repair we distinguish between process steps on the one hand (determining indications, imaging of the access vessels, measurement using IVUS and road mapping via fluoroscopy, selection of implant, implant insertion, positioning, setting the implant, determining success, reconstruction of the access vessel and follow-up) and the level of competence on the other (assistant, senior and directing physicians). Our ultrasound supported technique for endovascular aneurysms repair has been successfully brought to other hospitals using an IVUS transporter and telementoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is growing interest in the association of radiotherapy and immunotherapy for the treatment of solid tumors. Here, we report an extremely effective combination of local irradiation (IR) and Shiga Toxin B (STxB)-based human papillomavirus (HPV) vaccination for the treatment of HPV-associated head and neck squamous cell carcinoma (HNSCC). The efficacy of the irradiation and vaccine association was tested using a model of HNSCC obtained by grafting TC-1/luciferase cells at a submucosal site of the inner lip of immunocompetent mice. Irradiation and the STxB-E7 vaccine acted synergistically with both single and fractionated irradiation schemes, resulting in complete tumor clearance in the majority of the treated mice. A dose threshold of 7.5 Gy was required to elicit the dramatic antitumor response. The combined treatment induced high levels of tumor-infiltrating, antigen-specific CD8(+) T cells, which were required to trigger the antitumor activity. Treatment with STxB-E7 and irradiation induced CD8(+) T-cell memory, which was sufficient to exert complete antitumor responses in both local recurrences and distant metastases. We also report for the first time that a combination therapy based on local irradiation and vaccination induces an increased pericyte coverage (as shown by αSMA and NG2 staining) and ICAM-1 expression on vessels. This was associated with enhanced intratumor vascular permeability that correlated with the antitumor response, suggesting that the combination therapy could also act through an increased accessibility for immune cells. The combination strategy proposed here offers a promising approach that could potentially be transferred into early-phase clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes a solution for a restenosis and for the fracture of a stent in the vertebral artery in a patient suffering from vertebrobasilar symptoms. Angiography demonstrates restenosis of a vertebral stent as well as its fracture and migration into the subclavian artery. This complication was managed percutaneously by passing a guide wire through the fractured stent. Pre-dilatation and kissing balloon techniques were applied in both the vertebral and subclavian arteries to modify the stent's dimensions and shape it into the form of a "ring." Postprocedural angiography demonstrated an excellent final result with the assistance of StentBoost visualization. Control angiography at six months also utilized StentBoost imaging and confirmed the patency of the bifurcation and that the stent was not displaced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Right ventricular (RV) rupture in cases of mediastinitis following cardiac surgery is a rare and dangerous complication. Bleeding from the right ventricle occurs mainly after sternal reopening, due to either iatrogenic manipulation (wire removal, lesions due to wiring maneuvers) or mechanical shearing forces, producing direct injury. We present a case of RV wall perforation due to infection in a recurrent postoperative mediastinitis with a closed chest. The current literature on treatment of postoperative mediastinitis is also reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of ascending aortic graft infection by an atypical bacteria, Mycoplasma hominis, with mediastinitis, a dreaded complication after cardiac surgery. A 55-year-old patient underwent ascending aorta replacement for acute type A dissection. He developed sternal instability and purulent discharge, requiring sternal wire removal and debridement. Cultures were initially sterile, but showed M. hominis infection after a significant delay and in specific culture media. The patient was treated with doxycycline and moxifloxacine. Cultures became negative and the sternum was closed on the 28th postoperative day after the first debridement. Recovery was favorable, with no signs of infection. Antibiotics were continued for one year. The patient is still asymptomatic 16 months after antibiotic interruption. Atypical organisms should be considered in the differential diagnosis of acute mediastinitis of unknown etiology after routine microbiological investigations.