161 resultados para SIMPLE ASSAY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

During a 9-month period, 217 patients were newly diagnosed as methicillin-resistant Staphylococcus aureus (MRSA) carriers by using a commercial rapid PCR-based test (GeneXpert). However, no MRSA was recovered by culturing the second swab in 61 of these patients. Further analyses showed that 28 (12.9%) of the patients harbored S. aureus isolates with a staphylococcal cassette chromosome element lacking the mecA gene and were thus incorrectly determined to be MRSA carriers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this investigation was to improve the hemodynamics during venoarterial bypass by remote decompression of the left ventricle (LV). METHODS: Venoarterial bypass was established in 5 bovine experiments (69+/-10 kg) by the transjugular insertion of a self-expanding cannula (smartcanula) with return through a carotid artery. Cardiogenic shock was simulated with ventricular fibrillation induced by an external stimulator. Left ventricular decompression was achieved by switching to transfemoral drainage of the pulmonary artery (PA) with a long self-expanding cannula. RESULTS: Initial pump flow was 4.7+/-0.9 l/min and the aortic pressure accounted for 75+/-21 mmHg. After induction of ventricular fibrillation, the pump flow dropped after 11+/-8 min to 2.5+/-0.1 l/min. Transfemoral decompression increased the pump flow to 5.6+/-0.7 l/min, while the RV pressure decreased from 27+/-9 to 3+/-5 mmHg, the PA pressure decreased from 29+/-7 to 5+/-4 mmHg, the LV pressure decreased from 29+/-6 to 7+/-2 mmHg, and the aortic pressure increased from 31+/-3 to 47+/-11 mmHg. CONCLUSIONS: Remote drainage of the pulmonary artery during venoarterial bypass allows for effective decompression of the left ventricle and provides superior hemodynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dermatophytes are the main cause of superficial mycoses. These fungi have the capacity to invade keratinized tissue of humans or animals to produce infections that are generally restricted to the corneocytes of the skin, hair, and nails. Nevertheless, it is common to obtain negative results from fungal cultures of dermatological specimens where direct mycological examination showed fungal elements (30-40%). However, correct identification of the isolated dermatophytes from Tinea is important to choose the appropriate treatment. Therefore, we aim to develop a rapid polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) assay based on 28S rDNA that is able to identify dermatophytes species in positive dermatological samples. PCR-RFLP identification of dermatophytes in skin or hair allowed validation of the results obtained in culture. It was also possible to identify the infectious dermatophytes when direct hair/ skin mycological examination showed fungal elements, but negative results were obtained from fungal culture. As a conclusion, PCR methods may provide significant benefits in the rapid diagnosis of Tinea. First, there is an increase in sensitivity of dermatophytes identification when enough material is available. Secondly, identification of the infecting agent can be obtained in 24 hours with PCR-RFLP or sequencing, whereas results from fungal cultures can take 2-3 weeks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report outlines research undertaken as the result of a document examination case in which two envelopes were involved. The combination of the circumstances of the case and the results of the examination allows a simple application of a logical approach to pre-assess the probability that an envelope (or a package) potentially recovered at a suspect's home comes from the same batch (same source) as questioned envelopes. This highlights that it is useful to examine envelopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robust Huber type regression and testing of linear hypotheses are adapted to statistical analysis of parallel line and slope ratio assays. They are applied in the evaluation of results of several experiments carried out in order to compare and validate alternatives to animal experimentation based on embryo and cell cultures. Computational procedures necessary for the application of robust methods of analysis used the conversational statistical package ROBSYS. Special commands for the analysis of parallel line and slope ratio assays have been added to ROBSYS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Routine screening of patients at risk of hepatitis C virus (HCV) infection has become a priority given recent improvements in therapeutic options and the asymptomatic nature of most chronic infections. The aim of this study was to evaluate the performance of the Elecsys® Anti-HCV II assay, a new qualitative antibody immunoassay, compared with currently available assays, and assess its suitability for routine diagnostic testing. The sensitivity of the Elecsys® Anti-HCV II, ARCHITECT® Anti-HCV, AxSYM® HCV 3.0, PRISM® HCV, Vitros® ECi Anti-HCV, Elecsys® Anti-HCV, and ADVIA Centaur® HCV assays was compared using commercially available seroconversion panels and samples from patients known to be HCV positive and infected with HCV genotypes 1-6. Specificity was investigated using samples from blood donors, unselected hospitalized patients, and patients with potential cross-reacting factors or from high-risk groups. The Elecsys® Anti-HCV II assay detected more positive bleeds than the comparator assays, was more sensitive in recognizing early HCV infection, and correctly identified all 765 samples known to be HCV positive, regardless of genotype. The overall specificity of the Elecsys(®) Anti-HCV II assay was 99.84% (n = 6,850) using blood donor samples, 99.66% (n = 3,922) using samples from unselected hospitalized patients, and 99.66% (n = 2,397) using samples from patients with potentially cross-reacting factors or from high-risk groups. The specificity of the Elecsys® Anti-HCV II assay was superior or equal to the comparator assays. In conclusion, the Elecsys® Anti-HCV II assay is a sensitive and specific assay suitable for routine use in the reliable detection of anti-HCV antibodies. J. Med. Virol. 85:1362-1368, 2013. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arbuscular mycorrhizal fungi (AMF) are important symbionts of plants that improve plant nutrient acquisition and promote plant diversity. Although within-species genetic differences among AMF have been shown to differentially affect plant growth, very little is actually known about the degree of genetic diversity in AMF populations. This is largely because of difficulties in isolation and cultivation of the fungi in a clean system allowing reliable genotyping to be performed. A population of the arbuscular mycorrhizal fungus Glomus intraradices growing in an in vitro cultivation system was studied using newly developed simple sequence repeat (SSR), nuclear gene intron and mitochondrial ribosomal gene intron markers. The markers revealed a strong differentiation at the nuclear and mitochondrial level among isolates. Genotypes were nonrandomly distributed among four plots showing genetic subdivisions in the field. Meanwhile, identical genotypes were found in geographically distant locations. AMF genotypes showed significant preferences to different host plant species (Glycine max, Helianthus annuus and Allium porrum) used before the fungal in vitro culture establishment. Host plants in a field could provide a heterogeneous environment favouring certain genotypes. Such preferences may partly explain within-population patterns of genetic diversity.