67 resultados para Reagent Strips


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A gas chromatographic-mass spectrometric method is presented which allows the simultaneous determination of the plasma concentrations of fluvoxamine and of the enantiomers of fluoxetine and norfluoxetine after derivatization with the chiral reagent, (S)-(-)-N-trifluoroacetylprolyl chloride. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 10 to 750 ng/ml for racemic fluoxetine and norfluoxetine and of 50 to 500 ng/ml for fluvoxamine. Recoveries ranged from 50 to 66% for the three compounds. Intra- and inter-day coefficients of variation ranged from 4 to 10% for fluvoxamine and from 4 to 13% for fluoxetine and norfluoxetine. The limits of quantitation of the method were found to be 2 ng/ml for fluvoxamine and 1 ng/ml for the (R)- and (S)-enantiomers of fluoxetine and norfluoxetine, hence allowing its use for single dose pharmacokinetics. Finally, by using a steeper gradient of temperature, much shorter analysis times are obtained if one is interested in the concentrations of fluvoxamine alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the development of Arabidopsis and other land plants, diffusion barriers are formed in the apoplast of specialized tissues within a variety of plant organs. While the cuticle of the epidermis is the primary diffusion barrier in the shoot, the Casparian strips and suberin lamellae of the endodermis and the periderm represent the diffusion barriers in the root. Different classes of molecules contribute to the formation of extracellular diffusion barriers in an organ- and tissue-specific manner. Cutin and wax are the major components of the cuticle, lignin forms the early Casparian strip, and suberin is deposited in the stage II endodermis and the periderm. The current status of our understanding of the relationships between the chemical structure, ultrastructure and physiological functions of plant diffusion barriers is discussed. Specific aspects of the synthesis of diffusion barrier components and protocols that can be used for the assessment of barrier function and important barrier properties are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to provide a passive sampling approach which can be routinely used to investigate polychlorinated biphenyl (PCB) sources in rivers. The approach consists of deploying low density polyethylene (LDPE) strips downstream and upstream of potential PCB sources as well as in their water discharges. Concentrations of indicator PCBs (iPCBs) absorbed in samplers (Cs) from upstream and downstream sites are compared with each other to reveal increases of PCB levels. Cs measured in water discharges are used to determine if released amounts of PCBs are compatible with increases revealed in the river. As water velocity can greatly vary along a river stretch and influences the uptake at each site in a different way, differences in velocity have to be taken into account to correctly interpret Cs. LDPE strips were exposed to velocities between 1.6 and 37 cm s−1 using a channel system built in the field. Relationships between velocity and Cs were established for each iPCB to determine the expected change in Cs due to velocity variations. For PCBs 28 and 52, this change does not exceed a factor 2 for velocity variations in the range from 1.6 to 100 cm s−1 (extrapolated data above 37 cm s−1). For PCBs 101, 138, 153 and 180, this change only exceeds a factor 2 in the case of large velocity variations. The approach was applied in the Swiss river Venoge to first conduct a primary investigation of potential PCB sources and then conduct thorough investigations of two suspected sources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gacA gene of the biocontrol strain Pseudomonas fluorescens CHA0 codes for a response regulator which, together with the sensor kinase GacS (=LemA), is required for the production of exoenzymes and secondary metabolites involved in biocontrol, including hydrogen cyanide (HCN). A gacA multicopy suppressor was isolated from a cosmid library of strain CHA0 and identified as the infC-rpmI-rplT operon, which encodes the translation initiation factor IF3 and the ribosomal proteins L35 and L20. The efficiency of suppression was about 30%, as determined by the use of a GacA-controlled reporter construct, i.e. a translational hcnA'-'lacZ fusion. Overexpression of the rsmA gene (coding for a global translational repressor) reversed the suppressive effect of the amplified infC operon. This finding suggests that some product(s) of the infC operon can compete with RsmA at the level of translation in P. fluorescens CHA0 and that important biocontrol traits can be regulated at this level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a technetium labeling technology based on a new organometallic chemistry, which involves simple mixing of the novel reagent, a 99m Tc(I)-carbonyl compound, with a His-tagged recombinant protein. This method obviates the labeling of unpaired engineered cysteines, which frequently create problems in large-scale expression and storage of disulfide-containing proteins. In this study, we labeled antibody single-chain Fv fragments to high specific activities (90 mCi/mg), and the label was very stable to serum and all other challenges tested. The pharmacokinetic characteristics were indistinguishable from iodinated scFv fragments, and thus scFV fragments labeled by the new method will be suitable for biodistribution studies. This novel labeling method should be applicable not only to diagnostic imaging with 99mTc, but also to radioimmunotherapy approaches with 186/188 Re, and its use can be easily extended to almost any recombinant protein or synthetic peptide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Rotational thromboelastometry (ROTEM) is a whole blood point-of-test used to assess the patient's coagulation status. Three of the available ROTEM tests are EXTEM, INTEM and HEPTEM. In the latter, heparinase added to the INTEM reagent inactivates heparin to reveal residual heparin effect. Performing ROTEM analysis during cardiopulmonary bypass (CPB) might allow the anaesthesiologist to anticipate the need for blood products. OBJECTIVE: The goal of this study was to validate ROTEM analysis in the presence of very high heparin concentrations during CPB. DESIGN: Prospective, observational trial. SETTING: Single University Hospital. PARTICIPANTS: Twenty patients undergoing coronary artery bypass grafting. MAIN OUTCOME MEASURE: ROTEM analysis was performed before heparin administration (T0), 10 min after heparin (T1), at the end of CPB (T2) and 10 min after protamine (T3). The following tests were performed: EXTEM, INTEM, and HEPTEM. Heparin concentrations were measured at T1 and at the end of bypass (T2). RESULTS: At T1, EXTEM differed from baseline for coagulation time: +26.7 s (18.4 to 34.9, P < 0.0001), α: -3° (1.0 to 5.4, P = 0.006) and A10: -4.4 mm (2.3 to 6.5, P = 0.0004). INTEM at T0 was different from HEPTEM at T1 for coagulation time: + 47 s (34.3 to 59.6, P >0.0001), A10: -2.3 mm (0.5 to 4.0, P = 0.01) and α -2° (1.0 to 3.0; P = 0.0007). At T2, all parameters in EXTEM and HEPTEM related to fibrin-platelet interaction deteriorated significantly compared to T1. At T3, EXTEM and INTEM were comparable to EXTEM and HEPTEM at T2. CONCLUSION: HEPTEM and EXTEM measurements are valid in the presence of very high heparin concentrations and can be performed before protamine administration in patients undergoing cardiac surgery with CPB. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01455454.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identification and relative quantification of hundreds to thousands of proteins within complex biological samples have become realistic with the emergence of stable isotope labeling in combination with high throughput mass spectrometry. However, all current chemical approaches target a single amino acid functionality (most often lysine or cysteine) despite the fact that addressing two or more amino acid side chains would drastically increase quantifiable information as shown by in silico analysis in this study. Although the combination of existing approaches, e.g. ICAT with isotope-coded protein labeling, is analytically feasible, it implies high costs, and the combined application of two different chemistries (kits) may not be straightforward. Therefore, we describe here the development and validation of a new stable isotope-based quantitative proteomics approach, termed aniline benzoic acid labeling (ANIBAL), using a twin chemistry approach targeting two frequent amino acid functionalities, the carboxylic and amino groups. Two simple and inexpensive reagents, aniline and benzoic acid, in their (12)C and (13)C form with convenient mass peak spacing (6 Da) and without chromatographic discrimination or modification in fragmentation behavior, are used to modify carboxylic and amino groups at the protein level, resulting in an identical peptide bond-linked benzoyl modification for both reactions. The ANIBAL chemistry is simple and straightforward and is the first method that uses a (13)C-reagent for a general stable isotope labeling approach of carboxylic groups. In silico as well as in vitro analyses clearly revealed the increase in available quantifiable information using such a twin approach. ANIBAL was validated by means of model peptides and proteins with regard to the quality of the chemistry as well as the ionization behavior of the derivatized peptides. A milk fraction was used for dynamic range assessment of protein quantification, and a bacterial lysate was used for the evaluation of relative protein quantification in a complex sample in two different biological states

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two methods of differential isotopic coding of carboxylic groups have been developed to date. The first approach uses d0- or d3-methanol to convert carboxyl groups into the corresponding methyl esters. The second relies on the incorporation of two 18O atoms into the C-terminal carboxylic group during tryptic digestion of proteins in H(2)18O. However, both methods have limitations such as chromatographic separation of 1H and 2H derivatives or overlap of isotopic distributions of light and heavy forms due to small mass shifts. Here we present a new tagging approach based on the specific incorporation of sulfanilic acid into carboxylic groups. The reagent was synthesized in a heavy form (13C phenyl ring), showing no chromatographic shift and an optimal isotopic separation with a 6 Da mass shift. Moreover, sulfanilic acid allows for simplified fragmentation in matrix-assisted laser desorption/ionization (MALDI) due the charge fixation of the sulfonate group at the C-terminus of the peptide. The derivatization is simple, specific and minimizes the number of sample treatment steps that can strongly alter the sample composition. The quantification is reproducible within an order of magnitude and can be analyzed either by electrospray ionization (ESI) or MALDI. Finally, the method is able to specifically identify the C-terminal peptide of a protein by using GluC as the proteolytic enzyme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new lab-on-a-chip system for electrophysiological measurements on Xenopus oocytes. Xenopus oocytes are widely used host cells in the field of pharmacological studies and drug development. We developed a novel non-invasive technique using immobilized non-devitellinized cells that replaces the traditional "two-electrode voltage-clamp" (TEVC) method. In particular, rapid fluidic exchange was implemented on-chip to allow recording of fast kinetic events of exogenous ion channels expressed in the cell membrane. Reducing fluidic exchange times of extracellular reagent solutions is a great challenge with these large millimetre-sized cells. Fluidic switching is obtained by shifting the laminar flow interface in a perfusion channel under the cell by means of integrated poly-dimethylsiloxane (PDMS) microvalves. Reagent solution exchange times down to 20 ms have been achieved. An on-chip purging system allows to perform complex pharmacological protocols, making the system suitable for screening of ion channel ligand libraries. The performance of the integrated rapid fluidic exchange system was demonstrated by investigating the self-inhibition of human epithelial sodium channels (ENaC). Our results show that the response time of this ion channel to a specific reactant is about an order of magnitude faster than could be estimated with the traditional TEVC technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The genotyping of human papillomaviruses (HPV) is essential for the surveillance of HPV vaccines. We describe and validate a low-cost PGMY-based PCR assay (PGMY-CHUV) for the genotyping of 31 HPV by reverse blotting hybridization (RBH). Genotype-specific detection limits were 50 to 500 genome equivalents per reaction. RBH was 100% specific and 98.61% sensitive using DNA sequencing as the gold standard (n = 1,024 samples). PGMY-CHUV was compared to the validated and commercially available linear array (Roche) on 200 samples. Both assays identified the same positive (n = 182) and negative samples (n = 18). Seventy-six percent of the positives were fully concordant after restricting the comparison to the 28 genotypes shared by both assays. At the genotypic level, agreement was 83% (285/344 genotype-sample combinations; κ of 0.987 for single infections and 0.853 for multiple infections). Fifty-seven of the 59 discordant cases were associated with multiple infections and with the weakest genotypes within each sample (P < 0.0001). PGMY-CHUV was significantly more sensitive for HPV56 (P = 0.0026) and could unambiguously identify HPV52 in mixed infections. PGMY-CHUV was reproducible on repeat testing (n = 275 samples; 392 genotype-sample combinations; κ of 0.933) involving different reagents lots and different technicians. Discordant results (n = 47) were significantly associated with the weakest genotypes in samples with multiple infections (P < 0.0001). Successful participation in proficiency testing also supported the robustness of this assay. The PGMY-CHUV reagent costs were estimated at $2.40 per sample using the least expensive yet proficient genotyping algorithm that also included quality control. This assay may be used in low-resource laboratories that have sufficient manpower and PCR expertise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purified monoclonal antibodies (Mab) produced by 3 hybridomas and reacting with 3 different epitopes of carcinoembryonic antigen (CEA) were used in a solid phase enzyme immunoassay. Two Mabs were physically adsorbed to polystyrene balls and the third Mab was coupled to alkaline phosphatase using the bifunctional reagent N-succinimidyl-3-(2-pyridyldithio)-propionate. During a first incubation, CEA from heat-extracted serum samples was immunoadsorbed to the antibody coated balls. After washing of the balls, bound CEA was detected by a second incubation with the enzyme coupled Mab. The sensitivity of the assay was 0.6 ng per ml of serum. A total of 196 serum samples from patients with various types of carcinoma, with liver cirrhosis, or from healthy blood donors with or without smoking habits, were tested. The results obtained with the monoclonal enzyme immunoassay (M-EIA) were compared with those obtained with perchloric acid extracts of the same serum samples tested by an inhibition radioimmunoassay using conventional goat anti-CEA antiserum. There was an excellent correlation between the two assays. In particular, the new M-EIA gave good results for the detection of tumor recurrences in the follow-up of colon carcinoma patients. However, despite the use of exclusively monoclonal antibodies the new assay detected a similar percentage of slightly elevated CEA values as the conventional assay in patients with non-malignant disease, suggesting that the CEA associated with non-malignant diseases is immunologically identical to the CEA released by colon carcinoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We performed an international proficiency study of Human Papillomavirus (HPV) type 16 serology. A common methodology for serology based on virus-like particle (VLP) ELISA was used by 10 laboratories in 6 continents. The laboratories used the same VLP reference reagent, which was selected as the most stable, sensitive and specific VLP preparation out of VLPs donated from 5 different sources. A blinded proficiency panel consisting of 52 serum samples from women with PCR-verified HPV 16-infection, 11 control serum samples from virginal women and the WHO HPV 16 International Standard (IS) serum were distributed. The mean plus 3 standard deviations of the negative control serum samples was the most generally useful "cut-off" criterion for distinguishing positive and negative samples. Using sensitivity of at least 50% and a specificity of 100% as proficiency criteria, 6/10 laboratories were proficient. In conclusion, an international Standard Operating Procedure for HPV serology, an international reporting system in International Units (IU) and a common "cut-off" criterion have been evaluated in an international HPV serology proficiency study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Midazolam is a widely accepted probe for phenotyping cytochrome P4503A. A gas chromatography-mass spectrometry (GC-MS)-negative chemical ionization method is presented which allows measuring very low levels of midazolam (MID), 1-OH midazolam (1OHMID) and 4-OH midazolam (4OHMID), in plasma, after derivatization with the reagent N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. The standard curves were linear over a working range of 20 pg/ml to 5 ng/ml for the three compounds, with the mean coefficients of correlation of the calibration curves (n = 6) being 0.999 for MID and 1OHMID, and 1.0 for 4OHMID. The mean recoveries measured at 100 pg/ml, 500 pg/ml, and 2 ng/ml, ranged from 76 to 87% for MID, from 76 to 99% for 1OHMID, from 68 to 84% for 4OHMID, and from 82 to 109% for N-ethyloxazepam (internal standard). Intra- (n = 7) and inter-day (n = 8) coefficients of variation determined at three concentrations ranged from 1 to 8% for MID, from 2 to 13% for 1OHMID and from 1 to 14% for 4OHMID. The percent theoretical concentrations (accuracy) were within +/-8% for MID and 1OHMID, within +/-9% for 4OHMID at 500 pg/ml and 2 ng/ml, and within +/-28% for 4OHMID at 100 pg/ml. The limits of quantitation were found to be 10 pg/ml for the three compounds. This method can be used for phenotyping cytochrome P4503A in humans following the administration of a very low oral dose of midazolam (75 microg), without central nervous system side-effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Beryllium sensitization (BeS) is caused by exposure to beryllium in the workplace and may progress to chronic beryllium disease (CBD). This granulomatous lung disorder mimicks sarcoidosis clinically, but is characterized by beryllium specific CD4+ T-cells immune response. BeS is classically detected by beryllium lymphocyte proliferation test (BeLPT), but this assay requires radioactivity and is not very sensitive. In the context of a study aiming to evaluate if CBD patients are misdiagnosed as sarcoidosis patients in Switzerland, we developed EliSpot and CFSE beryllium flow cytometric test. Methods: 23 patients considered as having sarcoidosis (n = 21), CBD (n = 1) and possible CBD (n = 1) were enrolled. Elispot was performed using plate covered with gamma-IFN mAb. Cells were added to wells and incubated overnight at 37 °C with medium (neg ctrl), SEB (pos ctrl) or BeSO4 at 1, 10 and 100 microM. Anti-IFN-gamma biotinylated mAb were added and spots were visualized using streptavidinhorseradish peroxidase and AEC substrate reagent. Results were reported as spot forming unit (SFU). For Beryllium specific CFSE flow cytometry analysis, CFSE labelled cells were cultured in the presence of SEB and 1, 10 or 100 microM BeSO4. Unstimulated CFSE labeled cells were defined as controls. The cells were incubated for 6 days at 37 °C and 5% CO2. Surface labelling of T-lymphocytes and vivid as control of cells viability was performed at the time of harvest. Results: Using EliSpot technology, we were able to detect a BeS in 1/23 enrolled patients with a mean of 780 SFU (cut off value at 50 SFU). This positive result was confirmed using different concentration of BeSO4. Among the 23 patients tested, 22 showed negative results with EliSpot. Using CFSE flow cytometry, 1/7 tested patients showed a positive result with a beryllium specific CD4+ count around 30% versus 45% for SEB stimulation as positif control and 0.6 % for negative control. This patient was the one with a positive EliSpot assay. Conclusions: The preliminary data demonstrated the feasibility of Elispot and CFSE flow cytometry to detect BeS. The patient with a beryllium specific positive EliSpot and CFSE flow cytometry result had been exposed to beryllium at her workplace 20 years ago and is still regularly controlled for her pulmonary status. A positive BeLPT had already been described in 2001 in France for this patient. Further validation of these techniques are in progress.