57 resultados para Historically accurate reconstructions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multiscale finite-volume (MSFV) method is designed to reduce the computational cost of elliptic and parabolic problems with highly heterogeneous anisotropic coefficients. The reduction is achieved by splitting the original global problem into a set of local problems (with approximate local boundary conditions) coupled by a coarse global problem. It has been shown recently that the numerical errors in MSFV results can be reduced systematically with an iterative procedure that provides a conservative velocity field after any iteration step. The iterative MSFV (i-MSFV) method can be obtained with an improved (smoothed) multiscale solution to enhance the localization conditions, with a Krylov subspace method [e.g., the generalized-minimal-residual (GMRES) algorithm] preconditioned by the MSFV system, or with a combination of both. In a multiphase-flow system, a balance between accuracy and computational efficiency should be achieved by finding a minimum number of i-MSFV iterations (on pressure), which is necessary to achieve the desired accuracy in the saturation solution. In this work, we extend the i-MSFV method to sequential implicit simulation of time-dependent problems. To control the error of the coupled saturation/pressure system, we analyze the transport error caused by an approximate velocity field. We then propose an error-control strategy on the basis of the residual of the pressure equation. At the beginning of simulation, the pressure solution is iterated until a specified accuracy is achieved. To minimize the number of iterations in a multiphase-flow problem, the solution at the previous timestep is used to improve the localization assumption at the current timestep. Additional iterations are used only when the residual becomes larger than a specified threshold value. Numerical results show that only a few iterations on average are necessary to improve the MSFV results significantly, even for very challenging problems. Therefore, the proposed adaptive strategy yields efficient and accurate simulation of multiphase flow in heterogeneous porous media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we report the first ever large-scale environmental validation of a microbial reporter-based test to measure arsenic concentrations in natural water resources. A bioluminescence-producing arsenic-inducible bacterium based on Escherichia coli was used as the reporter organism. Specific protocols were developed with the goal to avoid the negative influence of iron in groundwater on arsenic availability to the bioreporter cells. A total of 194 groundwater samples were collected in the Red River and Mekong River Delta regions of Vietnam and were analyzed both by atomic absorption spectroscopy (AAS) and by the arsenic bioreporter protocol. The bacterial cells performed well at and above arsenic concentrations in groundwater of 7 microg/L, with an almost linearly proportional increase of the bioluminescence signal between 10 and 100 microg As/L (r2 = 0.997). Comparisons between AAS and arsenic bioreporter determinations gave an overall average of 8.0% false negative and 2.4% false positive identifications for the bioreporter prediction at the WHO recommended acceptable arsenic concentration of 10 microg/L, which is far betterthan the performance of chemical field test kits. Because of the ease of the measurement protocol and the low application cost, the microbiological arsenic test has a great potential in large screening campaigns in Asia and in other areas suffering from arsenic pollution in groundwater resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ammonium chloride procedure was used to prepare a bacterial pellet from positive blood cultures, which was used for direct inoculation of VITEK 2 cards. Correct identification reached 99% for Enterobacteriaceae and 74% for staphylococci. For antibiotic susceptibility testing, very major and major errors were 0.1 and 0.3% for Enterobacteriaceae, and 0.7 and 0.1% for staphylococci, respectively. Thus, bacterial pellets prepared with ammonium chloride allow direct inoculation of VITEK cards with excellent accuracy for Enterobacteriaceae and a lower accuracy for staphylococci.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While the incidence of sleep disorders is continuously increasing in western societies, there is a clear demand for technologies to asses sleep-related parameters in ambulatory scenarios. The present study introduces a novel concept of accurate sensor to measure RR intervals via the analysis of photo-plethysmographic signals recorded at the wrist. In a cohort of 26 subjects undergoing full night polysomnography, the wrist device provided RR interval estimates in agreement with RR intervals as measured from standard electrocardiographic time series. The study showed an overall agreement between both approaches of 0.05 ± 18 ms. The novel wrist sensor opens the door towards a new generation of comfortable and easy-to-use sleep monitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Accurate and reproducible tibial tunnel placement minimizing the risk of neurovascular damage is a crucial condition for successful arthroscopic reconstruction of the posterior cruciate ligament (PCL). This step is commonly performed under fluoroscopic control. Hypothesis: Performing the tibial tunnel under exclusive arthroscopic control allows accurate and reliable tunnel placement according to recommendations in the literature. Materials and Methods: Between February 2007 and December 2009, 108 arthroscopic single bundle PCL reconstructions in tibial tunnel technique were performed. The routine postoperative radiographs were screened according to previously defined quality criterions. After critical analysis, the radiographs of 48 patients (48 knees) were enrolled in the study. 10 patients had simultaneous ACL reconstruction and 7 had PCL revision surgery. The tibial tunnel was placed under direct arthroscopic control through a posteromedial portal using a standard tibial aming device. Key anatomical landmarks were the exposed tibial insertion of the PCL and the posterior horn of the medial meniscus. First, the centre of the posterior tibial tunnel outlet on the a-p view was determined by digital analysis of the postoperative radiographes. Its distance to the medial tibial spine was measured parallel to the tibia plateau. The mediolateral position was expressed by the ratio between the distance of the tunnel outlet to the medial border and the total width of the tibial plateau. On the lateral view the vertical tunnel position was measured perpendicularly to a tangent of the medial tibial plateau. All measurement were repeated at least twice and carried out by two examiners. Results: The mean mediolateral tunnel position was 49.3 ± 4.6% (ratio), 6.7 ± 3.6 mm lateral to the medial tibial spine. On the lateral view the tunnel centre was 10.1 ± 4.5 mm distal to the bony surface of the medial tibial plateau. Neurovascular damage was observed in none of our patients. Conclusion: The results of this radiological study confirm that exclusive arthroscopic control for tibial tunnel placement in PCL reconstruction yields reproducible and accurate results according to the literature. Our technique avoids radiation, facilitates the operation room setting and enables the surgeon to visualize the anatomic key landmarks for tibial tunnel placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early complications of myocutaneous flap transfers following surgical eradication of head and neck tumors have been extensively described. However, knowledge concerning long-term complications of these techniques remains limited. We report the cases of two patients with a prior history of squamous cell carcinoma of the head and neck (HNSCC), who developed a second primary SCC on the cutaneous surface of their flaps, years after reconstruction. Interestingly, it seems that the well-known risk of a second primary SCC in patients with previous head and neck carcinoma also applies to foreign tissues implanted within the area at risk. Given the important expansion of these interventions, this type of complication may become more frequent in the future. Therefore, long-term follow-up of patients previously treated for HNSCC not only requires careful evaluation of the normal mucosa of the upper aero-digestive tract, but also of the cutaneous surface of the flap used for reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The physical disector is a method of choice for estimating unbiased neuron numbers; nevertheless, calibration is needed to evaluate each counting method. The validity of this method can be assessed by comparing the estimated cell number with the true number determined by a direct counting method in serial sections. We reconstructed a 1/5 of rat lumbar dorsal root ganglia taken from two experimental conditions. From each ganglion, images of 200 adjacent semi-thin sections were used to reconstruct a volumetric dataset (stack of voxels). On these stacks the number of sensory neurons was estimated and counted respectively by physical disector and direct counting methods. Also, using the coordinates of nuclei from the direct counting, we simulate, by a Matlab program, disector pairs separated by increasing distances in a ganglion model. The comparison between the results of these approaches clearly demonstrates that the physical disector method provides a valid and reliable estimate of the number of sensory neurons only when the distance between the consecutive disector pairs is 60 microm or smaller. In these conditions the size of error between the results of physical disector and direct counting does not exceed 6%. In contrast when the distance between two pairs is larger than 60 microm (70-200 microm) the size of error increases rapidly to 27%. We conclude that the physical dissector method provides a reliable estimate of the number of rat sensory neurons only when the separating distance between the consecutive dissector pairs is no larger than 60 microm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Prospective evaluation of tracheo-carinal airway reconstructions using pedicled extrathoracic muscle flaps for closing airway defects after non-circumferential resections and after carinal resections as part of the reconstruction for alleviation of anastomotic tension. METHODS: From January 1996 to June 2006, 41 patients underwent tracheo-carinal airway reconstructions using 45 extrathoracic muscle flaps (latissimus dorsi, n=25; serratus anterior, n=18; pectoralis major, n=2) for closing airway defects resulting from (a) bronchopleural fistulas (BPF) with short desmoplastic bronchial stumps after right upper lobectomy (n=1) and right-sided (pleuro) pneumonectomy (n=13); (b) right (n=9) and left (n=3) associated with partial carinal resections for pre-treated centrally localised tumours; (c) partial non-circumferential tracheal resections for pre-treated tracheal tumours, tracheo-oesophageal fistulas (TEF) and chronic tracheal injury with tracheomalacia (n=11); (d) carinal resections with the integration of a muscle patch in specific parts of the anastomotic reconstruction for alleviation of anastomotic tension (n=4). The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. The patients were followed by clinical examination, repeated bronchoscopy, pulmonary function testing and CT scans. The minimum follow-up time was 6 months. RESULTS: Ninety-day mortality was 7.3% (3/41 patients). Four patients (9.7%) sustained muscle flap necrosis requiring re-operation and flap replacement without subsequent mortality, airway dehiscence or stenosis. Airway dehiscence was observed in 1/41 patients (2.4%) and airway stenosis in 1/38 surviving patients (2.6%) responding well to topical mitomycin application. Follow-up on clinical grounds, by CT scans and repeated bronchoscopy, revealed airtight, stable and epithelialised airways and no recurrence of BPF or TEF in all surviving patients. CONCLUSIONS: Tracheo-carinal airway defects can be closed by use of pedicled extrathoracic muscle flaps after non-circumferential resections and after carinal resections with the muscle patch as part of the reconstruction for alleviation of anastomotic tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work, derived from a full global geodynamic reconstruction model over 600 Ma and based on a large database, focuses herein on the interaction between the Pacific, Australian and Antarctic plates since 200 Ma, and proposes integrated solutions for a coherent, physically consistent scenario. The evolution of the Australia-Antarctica-West Pacific plate system is dependent on the Gondwana fit chosen for the reconstruction. Our fit, as defined for the latest Triassic, implies an original scenario for the evolution of the region, in particular for the "early" opening history of the Tasman Sea. The interaction with the Pacific, moreover, is characterised by many magmatic arc migrations and ocean openings, which are stopped by arc-arc collision, arc-spreading axis collision, or arc-oceanic plateau collision, and subduction reversals. Mid-Pacific oceanic plateaus created in the model are much wider than they are on present-day maps, and although they were subducted to a large extent, they were able to stop subduction. We also suggest that adduction processes (i.e., re-emergence of subducted material) may have played an important role, in particular along the plate limit now represented by the Alpine Fault in New Zealand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous studies have documented subtle but consistent sex differences in self-reports and observer-ratings of five-factor personality traits, and such effects were found to show well- defined developmental trajectories and remarkable similarity across nations. In contrast, very little is known about perceived gender differences in five-factor traits in spite of their potential implications for gender biases at the interpersonal and societal level. In particular, it is not clear how perceived gender differences in five-factor personality vary across age groups and national contexts and to what extent they accurately reflect assessed sex differences in personality. To address these questions, we analyzed responses from 3,323 individuals across 26 nations (mean age = 22.3 years, 31% male) who were asked to rate the five-factor personality traits of typical men or women in three age groups (adolescent, adult, and older adult) in their respective nations. Raters perceived women as slightly higher in openness, agreeableness, and conscientiousness as well as some aspects of extraversion and neuroticism. Perceived gender differences were fairly consistent across nations and target age groups and mapped closely onto assessed sex differences in self- and observer-rated personality. Associations between the average size of perceived gender differences and national variations in sociodemographic characteristics, value systems, or gender equality did not reach statistical significance. Findings contribute to our understanding of the underlying mechanisms of gender stereotypes of personality and suggest that perceptions of actual sex differences may play a more important role than culturally based gender roles and socialization processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Age trajectories for personality traits are known to be similar across cultures. To address whether stereotypes of age groups reflect these age-related changes in personality, we asked participants in 26 countries (N = 3,323) to rate typical adolescents, adults, and old persons in their own country. Raters across nations tended to share similar beliefs about different age groups; adolescents were seen as impulsive, rebellious, undisciplined, preferring excitement and novelty, whereas old people were consistently considered lower on impulsivity, activity, antagonism, and Openness. These consensual age group stereotypes correlated strongly with published age differences on the five major dimensions of personality and most of 30 specific traits, using as criteria of accuracy both self-reports and observer ratings, different survey methodologies, and data from up to 50 nations. However, personal stereotypes were considerably less accurate, and consensual stereotypes tended to exaggerate differences across age groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proper and rapid diagnosis of orthopedic device-related infection is important for successful treatment. Sonication has been shown to improve the diagnostic performance. We hypothesized that the combination of sonication with a novel method called microcalorimetry will further improve and accelerate the diagnosis of implant infection. We prospectively included 39 consecutive patients (mean age 59 years, 62% males) at our institution from whom 29 orthopedic prostheses and 10 osteosynthesis material were explanted. The explanted device was sonicated. The resulting sonication fluid was analyzed using microcalorimetry. Using standardized criteria to define orthopedic device-related infection, 12 cases (31%) were defined as infected. In all, positive periprosthetic tissue cultures were found. The sensitivity and specificity of microcalorimetry of sonication fluid were 100% and 97%, respectively. Mean time to detection, defined as time to reach a rising heat flow signal of 20 µW measured after equilibiration needed to get accurate measurement, was 10.9 h. In summary, microcalorimetry of sonication fluid is a reliable and a fast method in detecting the presence of microorganisms in orthopedic device-related infection. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1700-1703, 2013.