43 resultados para Fentons reagent
Resumo:
Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.
Resumo:
The main goal of CleanEx is to provide access to public gene expression data via unique gene names. A second objective is to represent heterogeneous expression data produced by different technologies in a way that facilitates joint analysis and cross-data set comparisons. A consistent and up-to-date gene nomenclature is achieved by associating each single experiment with a permanent target identifier consisting of a physical description of the targeted RNA population or the hybridization reagent used. These targets are then mapped at regular intervals to the growing and evolving catalogues of human genes and genes from model organisms. The completely automatic mapping procedure relies partly on external genome information resources such as UniGene and RefSeq. The central part of CleanEx is a weekly built gene index containing cross-references to all public expression data already incorporated into the system. In addition, the expression target database of CleanEx provides gene mapping and quality control information for various types of experimental resource, such as cDNA clones or Affymetrix probe sets. The web-based query interfaces offer access to individual entries via text string searches or quantitative expression criteria. CleanEx is accessible at: http://www.cleanex.isb-sib.ch/.
Resumo:
Tuberculin skin test (TST) has been used for 100 years for the diagnosis of latent tuberculosis (TB) infection (LTBI). In recent years, increasing interest in the diagnosis of TB has led to the development of new assays. QuantiFERON-TB Gold (QFT-G) is an IFN-gamma-release assay that measures the release of interferon after stimulation in vitro by Mycobacterium tuberculosis antigens. The main advantage of this assay with respect to TST is the lack of crossreaction with bacillus Calmette-Guérin and most nontuberculous mycobacteria. QFT-G also eliminates the need for the patient to return for test reading in 48-72 h. In the immunocompromised host and in pediatric populations, studies suggest that the QFT-G better correlates with the risk of TB than the TST, but data remain inconclusive. In contrast to TST, there are no prospective studies regarding the association of the QFT-G result and the risk for development of TB. Given its advantages, the QFT-G may become the standard test for the diagnosis of LTBI.
Resumo:
OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.
Resumo:
Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.
Resumo:
The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.
Resumo:
A gas chromatography-mass spectrometry method is presented which allows the simultaneous determination of the plasma concentrations of the selective serotonin reuptake inhibitors citalopram, paroxetine, sertraline, and their pharmacologically active N-demethylated metabolites (desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline) after derivatization with the reagent N-methyl-bis(trifluoroacetamide). No interferences from endogenous compounds are observed following the extraction of plasma samples from six different human subjects. The standard curves are linear over a working range of 10-500 ng/mL for citalopram, 10-300 ng/mL for desmethylcitalopram, 5-60 ng/mL for didesmethylcitalopram, 20-400 ng/mL for sertraline and desmethylsertraline, and 10-200 ng/mL for paroxetine. Recoveries measured at three concentrations range from 81 to 118% for the tertiary amines (citalopram and the internal standard methylmaprotiline), 73 to 95% for the secondary amines (desmethylcitalopram, paroxetine and sertraline), and 39 to 66% for the primary amines (didesmethylcitalopram and desmethylsertraline). Intra- and interday coefficients of variation determined at three concentrations range from 3 to 11% for citalopram and its metabolites, 4 to 15% for paroxetine, and 5 to 13% for sertraline and desmethylsertraline. The limits of quantitation of the method are 2 ng/mL for citalopram and paroxetine, 1 ng/mL for sertraline, and 0.5 ng/mL for desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline. No interferences are noted from 20 other psychotropic drugs. This sensitive and specific method can be used for single-dose pharmacokinetics. It is also useful for therapeutic drug monitoring of these three drugs and could possibly be adapted for the quantitation of the two other selective serotonin reuptake inhibitors on the market, namely fluoxetine and fluvoxamine.
Resumo:
The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.
Resumo:
IMPORTANCE OF THE FIELD: Promising immunotherapeutic agents targeting co-stimulatory pathways are currently being tested in clinical trials. One player in this array of regulatory pathways is the LAG-3/MHC class II axis. The lymphocyte activation gene-3 (LAG-3) is a negative co-stimulatory receptor that modulates T cell homeostasis, proliferation and activation. A recombinant soluble dimeric form of LAG-3 (sLAG-3-Ig, IMP321) shows adjuvant properties and enhances immunogenicity of tumor vaccines. Recent clinical trials produced encouraging results, especially when the human dimeric soluble form of LAG-3 (hLAG-3-Ig) was used in combination with chemotherapy. AREAS COVERED IN THIS REVIEW: The biological relevance of LAG-3 in vivo. Pre-clinical data demonstrating adjuvant properties, as well as the improvement of tumor immunity by sLAG-3-Ig. Recent advances in the clinical development of the therapeutic reagent IMP321, hLAG-3-Ig, for cancer treatment. WHAT THE READER WILL GAIN: This review summarizes preclinical and clinical data on the biological functions of LAG-3. TAKE HOME MESSAGE: The LAG-3 inhibitory pathway is attracting attention, in the light of recent studies demonstrating its role in T cell unresponsiveness, and Treg function after chronic antigen stimulation. As a soluble recombinant dimer, the sLAG-3-Ig protein acts as an adjuvant for therapeutic induction of T cell responses, and may be beneficial to cancer patients when used in combination therapies.
Resumo:
Spleen cells from mice immunized with purified carcinoembryonic antigen (CEA), an important tumor marker of human carcinomas, were fused with the mouse myeloma cell line P3-NSI/1-Ag4. Out of the 400 hybrids obtained, 2 secreted antibodies reacting specifically with two different antigenic determinants present on CEA molecules. They were cloned and established as permanent hybridoma cell lines. These antibodies, which have relatively high-affinities and can be produced in unlimited amounts, will be useful both for the immunochemical characterization of CEA and as a standard reagent for the identification of this antigen in human tissues and body fluids.
Resumo:
Résumé: L'automatisation du séquençage et de l'annotation des génomes, ainsi que l'application à large échelle de méthodes de mesure de l'expression génique, génèrent une quantité phénoménale de données pour des organismes modèles tels que l'homme ou la souris. Dans ce déluge de données, il devient très difficile d'obtenir des informations spécifiques à un organisme ou à un gène, et une telle recherche aboutit fréquemment à des réponses fragmentées, voir incomplètes. La création d'une base de données capable de gérer et d'intégrer aussi bien les données génomiques que les données transcriptomiques peut grandement améliorer la vitesse de recherche ainsi que la qualité des résultats obtenus, en permettant une comparaison directe de mesures d'expression des gènes provenant d'expériences réalisées grâce à des techniques différentes. L'objectif principal de ce projet, appelé CleanEx, est de fournir un accès direct aux données d'expression publiques par le biais de noms de gènes officiels, et de représenter des données d'expression produites selon des protocoles différents de manière à faciliter une analyse générale et une comparaison entre plusieurs jeux de données. Une mise à jour cohérente et régulière de la nomenclature des gènes est assurée en associant chaque expérience d'expression de gène à un identificateur permanent de la séquence-cible, donnant une description physique de la population d'ARN visée par l'expérience. Ces identificateurs sont ensuite associés à intervalles réguliers aux catalogues, en constante évolution, des gènes d'organismes modèles. Cette procédure automatique de traçage se fonde en partie sur des ressources externes d'information génomique, telles que UniGene et RefSeq. La partie centrale de CleanEx consiste en un index de gènes établi de manière hebdomadaire et qui contient les liens à toutes les données publiques d'expression déjà incorporées au système. En outre, la base de données des séquences-cible fournit un lien sur le gène correspondant ainsi qu'un contrôle de qualité de ce lien pour différents types de ressources expérimentales, telles que des clones ou des sondes Affymetrix. Le système de recherche en ligne de CleanEx offre un accès aux entrées individuelles ainsi qu'à des outils d'analyse croisée de jeux de donnnées. Ces outils se sont avérés très efficaces dans le cadre de la comparaison de l'expression de gènes, ainsi que, dans une certaine mesure, dans la détection d'une variation de cette expression liée au phénomène d'épissage alternatif. Les fichiers et les outils de CleanEx sont accessibles en ligne (http://www.cleanex.isb-sib.ch/). Abstract: The automatic genome sequencing and annotation, as well as the large-scale gene expression measurements methods, generate a massive amount of data for model organisms. Searching for genespecific or organism-specific information througout all the different databases has become a very difficult task, and often results in fragmented and unrelated answers. The generation of a database which will federate and integrate genomic and transcriptomic data together will greatly improve the search speed as well as the quality of the results by allowing a direct comparison of expression results obtained by different techniques. The main goal of this project, called the CleanEx database, is thus to provide access to public gene expression data via unique gene names and to represent heterogeneous expression data produced by different technologies in a way that facilitates joint analysis and crossdataset comparisons. A consistent and uptodate gene nomenclature is achieved by associating each single gene expression experiment with a permanent target identifier consisting of a physical description of the targeted RNA population or the hybridization reagent used. These targets are then mapped at regular intervals to the growing and evolving catalogues of genes from model organisms, such as human and mouse. The completely automatic mapping procedure relies partly on external genome information resources such as UniGene and RefSeq. The central part of CleanEx is a weekly built gene index containing crossreferences to all public expression data already incorporated into the system. In addition, the expression target database of CleanEx provides gene mapping and quality control information for various types of experimental resources, such as cDNA clones or Affymetrix probe sets. The Affymetrix mapping files are accessible as text files, for further use in external applications, and as individual entries, via the webbased interfaces . The CleanEx webbased query interfaces offer access to individual entries via text string searches or quantitative expression criteria, as well as crossdataset analysis tools, and crosschip gene comparison. These tools have proven to be very efficient in expression data comparison and even, to a certain extent, in detection of differentially expressed splice variants. The CleanEx flat files and tools are available online at: http://www.cleanex.isbsib. ch/.
Resumo:
Solid tumor growth triggers a wound healing response. Similar to wound healing, fibroblasts in the tumor stroma differentiate into myofibroblasts (also referred to as cancer-associated fibroblasts) primarily, but not exclusively, in response to transforming growth factor-β (TGF-β). Myofibroblasts in turn enhance tumor progression by remodeling the stroma. Among proteases implicated in stroma remodeling, matrix metalloproteinases (MMPs), including MMP-9, play a prominent role. Recent evidence indicates that MMP-9 recruitment to the tumor cell surface enhances tumor growth and invasion. In the present work, we addressed the potential relevance of MMP-9 recruitment to and activity at the surface of fibroblasts. We show that recruitment of MMP-9 to the fibroblast cell surface occurs through its fibronectin-like (FN) domain and that the molecule responsible for the recruitment is lysyl hydroxylase 3 (LH3). Functional assays suggest that both pro- and active MMP-9 trigger α-smooth muscle actin expression in cultured fibroblasts, reflecting myofibroblast differentiation, possibly as a result of TGF-β activation. Moreover, the recombinant FN domain inhibited both MMP-9-induced TGF-β activation and α-smooth muscle actin expression by displacing MMP-9 from the fibroblast cell surface. Together our results uncover LH3 as a new docking receptor of MMP-9 on the fibroblast cell surface and demonstrate that the MMP-9 FN domain is essential for the interaction. They also show that the recombinant FN domain inhibits MMP-9-induced TGF-β activation and fibroblast differentiation, providing a potentially attractive therapeutic reagent toward attenuating tumor progression where MMP-9 activity is strongly implicated.
Resumo:
Differences in parasite transmission intensity influence the process of acquisition of host immunity to Plasmodium falciparum malaria and ultimately, the rate of malaria related morbidity and mortality. Potential vaccines being designed to complement current intervention efforts therefore need to be evaluated against different malaria endemicity backgrounds. The associations between antibody responses to the chimeric merozoite surface protein 1 block 2 hybrid (MSP1 hybrid), glutamate-rich protein region 2 (GLURP R2) and the peptide AS202.11, and the risk of malaria were assessed in children living in malaria hyperendemic (Burkina Faso, n = 354) and hypo-endemic (Ghana, n = 209) areas. Using the same reagent lots and standardized protocols for both study sites, immunoglobulin (Ig) M, IgG and IgG sub-class levels to each antigen were measured by ELISA in plasma from the children (aged 6-72 months). Associations between antibody levels and risk of malaria were assessed using Cox regression models adjusting for covariates. There was a significant association between GLURP R2 IgG3 and reduced risk of malaria after adjusting age of children in both the Burkinabe (hazard ratio 0.82; 95 % CI 0.74-0.91, p < 0.0001) and the Ghanaian (HR 0.48; 95 % CI 0.25-0.91, p = 0.02) cohorts. MSP1 hybrid IgM was associated (HR 0.85; 95 % CI 0.73-0.98, p = 0.02) with reduced risk of malaria in Burkina Faso cohort while IgG against AS202.11 in the Ghanaian children was associated with increased risk of malaria (HR 1.29; 95 % CI 1.01-1.65, p = 0.04). These findings support further development of GLURP R2 and MSP1 block 2 hybrid, perhaps as a fusion vaccine antigen targeting malaria blood stage that can be deployed in areas of varying transmission intensity.