122 resultados para Digital atlas
Resumo:
OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.
Resumo:
Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE
Resumo:
The field of classical studies has undergone a radical transformation with the arrival of the digital age, particularly with regard to the editing of ancient texts. As Umberto Eco (2003) pointed out, the digital age may mean the end of the history of variants and of the notion of the "original text." Among the texts of antiquity, the editing of Homer and of the New Testament are more especially susceptible to the effects of digital technology because of their numerous manuscripts. Whereas the "Homer Multitext" project recognizes that the notion of a synthetic critical edition is now seriously brought into question, the prototype of the online Greek New Testament continues to be based on the aim of obtaining a unique text, in the style of a printed critical edition. As it moves from a printed culture to the digital age, the editing of the Greek NT is also confronted by the emergence of non-Western scholarship. For example, the presence is to be noted of Arabic Muslim websites that examine Greek New Testament manuscripts but without directly interacting with Western scholarship.
Resumo:
Geological research on the Mediterranean region is presently characterized by the transition from disciplinary to multidisciplinary research, as well as from national to international investigations. In order to synthesize and integrate the vast disciplinary and national datasets which are available, it is necessary to implement maximum interaction among geoscientists of different backgrounds. The creation of project-oriented task forces in universities and other research institutions, as well as the development of large international cooperation programs, is instrumental in pursuing such a multidisciplinary and supranational approach. The TRANSMED Atlas, an official publication of the 32nd International Geological Congress (Florence 2004), is the result of an international scientific cooperation program which brought together for over two years sixty-three structural geologists, geophysicists, marine geologists, petrologists, sedimentologists, stratigraphers, paleogeographers, and petroleum geologists coming from eighteen countries, and working for the petroleum industry, academia, and other institutions, both public and private. The TRANSMED Atlas provides an updated, synthetic, and coherent portrayal of the overall geological-geophysical structure of the Mediterranean domain and the surrounding areas. The initial stimulus for the Atlas came from the realization of the extremely heterogeneous nature of the existing geological-geophysical data about such domain. These data have been gathered by universities, oil companies, geological surveys and other institutions in several countries, often using different procedures and standards. In addition, much of these data are written in languages and published in outlets that are not readily accessible to the general international reader. By synthesizing and integrating a wealth of preexisting and new data derived from surficial geology, seismic sections at various scales, and mantle tomographies, the TRANSMED Atlas provides for the first time a coherent geological overview of the Mediterranean region and represents an ideal springboard for future studies.
Resumo:
We present first results on a method enabling mechanical scanning-free tomography with submicrometer axial resolution by multiple-wavelength digital holographic microscopy. By sequentially acquiring reflection holograms and summing 20 wavefronts equally spaced in spatial frequency in the 485-670 nm range, we are able to achieve a slice-by-slice tomographic reconstruction with a 0.6-1 mum axial resolution in a biological medium. The method is applied to erythrocytes investigation to retrieve the cellular membrane profile in three dimensions.
Resumo:
In this paper, we propose a new paradigm to carry outthe registration task with a dense deformation fieldderived from the optical flow model and the activecontour method. The proposed framework merges differenttasks such as segmentation, regularization, incorporationof prior knowledge and registration into a singleframework. The active contour model is at the core of ourframework even if it is used in a different way than thestandard approaches. Indeed, active contours are awell-known technique for image segmentation. Thistechnique consists in finding the curve which minimizesan energy functional designed to be minimal when thecurve has reached the object contours. That way, we getaccurate and smooth segmentation results. So far, theactive contour model has been used to segment objectslying in images from boundary-based, region-based orshape-based information. Our registration technique willprofit of all these families of active contours todetermine a dense deformation field defined on the wholeimage. A well-suited application of our model is theatlas registration in medical imaging which consists inautomatically delineating anatomical structures. Wepresent results on 2D synthetic images to show theperformances of our non rigid deformation field based ona natural registration term. We also present registrationresults on real 3D medical data with a large spaceoccupying tumor substantially deforming surroundingstructures, which constitutes a high challenging problem.
Resumo:
In medical imaging, merging automated segmentations obtained from multiple atlases has become a standard practice for improving the accuracy. In this letter, we propose two new fusion methods: "Global Weighted Shape-Based Averaging" (GWSBA) and "Local Weighted Shape-Based Averaging" (LWSBA). These methods extend the well known Shape-Based Averaging (SBA) by additionally incorporating the similarity information between the reference (i.e., atlas) images and the target image to be segmented. We also propose a new spatially-varying similarity-weighted neighborhood prior model, and an edge-preserving smoothness term that can be used with many of the existing fusion methods. We first present our new Markov Random Field (MRF) based fusion framework that models the above mentioned information. The proposed methods are evaluated in the context of segmentation of lymph nodes in the head and neck 3D CT images, and they resulted in more accurate segmentations compared to the existing SBA.
Resumo:
Carbonatites of the Eocene Tamazeght complex, High Atlas Mountains, Morocco, consist of calciocarbonatites (alvikite and sovite dykes) and magnesiocarbonatites (diatreme breccias and dykes rocks). These are associated with ultramafic, shonkinitic, gabbroic to monzonitic and various foid syenitic silicate units. Stable and radiogenic isotope compositions for carbonatites and silicate rocks indicate that they share a common source in the mantle, although for some carbonatitic samples contamination with sedimentary rocks seems important. The observed isotopic heterogeneity is mainly attributed to source characteristics, fractional crystallization (accompanied by various degrees of assimilation), and late- to post-magmatic fluid-rock interaction. During the late fluid-rock interaction, Sr, Mn, and possibly also Fe were mobilized and redistributed to form secondary carbonate minerals in carbonatites. These fluids also penetrated into the adjacent syenitic rocks, causing enrichment in the same elements.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.