72 resultados para Commercial paper
Resumo:
BACKGROUND: Cardiovascular diseases (CVD) cause 1.8 million premature (<75 years) death annually in Europe. The majority of these deaths are preventable with the most efficient and cost-effective approach being on the population level. The aim of this position paper is to assist authorities in selecting the most adequate management strategies to prevent CVD. DESIGN AND METHODS: Experts reviewed and summarized the published evidence on the major modifiable CVD risk factors: food, physical inactivity, smoking, and alcohol. Population-based preventive strategies focus on fiscal measures (e.g. taxation), national and regional policies (e.g. smoke-free legislation), and environmental changes (e.g. availability of alcohol). RESULTS: Food is a complex area, but several strategies can be effective in increasing fruit and vegetables and lowering intake of salt, saturated fat, trans-fats, and free sugars. Tobacco and alcohol can be regulated mainly by fiscal measures and national policies, but local availability also plays a role. Changes in national policies and the built environment will integrate physical activity into daily life. CONCLUSION: Societal changes and commercial influences have led to the present unhealthy environment, in which default option in life style increases CVD risk. A challenge for both central and local authorities is, therefore, to ensure healthier defaults. This position paper summarizes the evidence and recommends a number of structural strategies at international, national, and regional levels that in combination can substantially reduce CVD.
Resumo:
Rock-paper-scissors (RPS) dynamics, which maintain genetic polymorphisms over time through negative frequency-dependent (FD) selection, can evolve in short-lived species with no generational overlap, where they produce rapid morph frequency cycles. However, most species have overlapping generations and thus, rapid RPS dynamics are thought to require stronger FD selection, the existence of which yet needs to be proved. Here, we experimentally demonstrate that two cumulative selective episodes, FD sexual selection reinforced by FD selection on offspring survival, generate sufficiently strong selection to generate rapid morph frequency cycles in the European common lizard Zootoca vivipara, a multi-annual species with major generational overlap. These findings show that the conditions required for the evolution of RPS games are fulfilled by almost all species exhibiting genetic polymorphisms and suggest that RPS games may be responsible for the maintenance of genetic diversity in a wide range of species.
Resumo:
Pneumocystis jirovecii pneumonia (PCP) is a common opportunistic infection. Microscopic diagnosis, including diagnosis using the Merifluor-Pneumocystis direct fluorescent antigen (MP-DFA) test, has limitations. Real-time PCR may assist in diagnosis, but no commercially validated real-time PCR assay has been available to date. MycAssay Pneumocystis is a commercial assay that targets the P. jirovecii mitochondrial large subunit (analytical detection limit, ≤3.5 copies/μl of sample). A multicenter trial recruited 110 subjects: 54 with transplants (40 with lung transplants), 32 with nonmalignant conditions, 13 with leukemia, and 11 with solid tumors; 9 were HIV positive. A total of 110 respiratory samples (92% of which were bronchoalveolar lavage [BAL] specimens) were analyzed by PCR. Performance was characterized relative to investigator-determined clinical diagnosis of PCP (including local diagnostic tests), and PCR results were compared with MP-DFA test results for 83 subjects. Thirteen of 14 subjects with PCP and 9/96 without PCP (including 5 undergoing BAL surveillance after lung transplantation) had positive PCR results; sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) were 93%, 91%, 59%, and 99%, respectively. Fourteen of 83 subjects for whom PCR and MP-DFA test results were available had PCP; PCR sensitivity, specificity, PPV, and NPV were 93%, 90%, 65%, and 98%, respectively, and MP-DFA test sensitivity, specificity, PPV, and NPV were 93%, 100%, 100%, and 98%. Of the 9 PCR-positive subjects without PCP, 1 later developed PCP. The PCR diagnostic assay compares well with clinical diagnosis using nonmolecular methods. Additional positive results compared with the MP-DFA test may reflect low-level infection or colonization.
Resumo:
Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.
Resumo:
BACKGROUND: As part of EUROCAT's surveillance of congenital anomalies in Europe, a statistical monitoring system has been developed to detect recent clusters or long-term (10 year) time trends. The purpose of this article is to describe the system for the identification and investigation of 10-year time trends, conceived as a "screening" tool ultimately leading to the identification of trends which may be due to changing teratogenic factors.METHODS: The EUROCAT database consists of all cases of congenital anomalies including livebirths, fetal deaths from 20 weeks gestational age, and terminations of pregnancy for fetal anomaly. Monitoring of 10-year trends is performed for each registry for each of 96 non-independent EUROCAT congenital anomaly subgroups, while Pan-Europe analysis combines data from all registries. The monitoring results are reviewed, prioritized according to a prioritization strategy, and communicated to registries for investigation. Twenty-one registries covering over 4 million births, from 1999 to 2008, were included in monitoring in 2010.CONCLUSIONS: Significant increasing trends were detected for abdominal wall anomalies, gastroschisis, hypospadias, Trisomy 18 and renal dysplasia in the Pan-Europe analysis while 68 increasing trends were identified in individual registries. A decreasing trend was detected in over one-third of anomaly subgroups in the Pan-Europe analysis, and 16.9% of individual registry tests. Registry preliminary investigations indicated that many trends are due to changes in data quality, ascertainment, screening, or diagnostic methods. Some trends are inevitably chance phenomena related to multiple testing, while others seem to represent real and continuing change needing further investigation and response by regional/national public health authorities.
Resumo:
Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.
Resumo:
Chronique de jurisprudence et de législation pour l'année 2008
Resumo:
Motherhood and reproduction have been at the core of the feminist discourse about women's rights ever since its onset. For the first and second feminist movements, the right to abortion and the public recognition of motherhood have been main issues in the discourse on reproduction. Since the last two dec- ades of the 20th century, the potentials of assisted reproductive technologies (ART) have opened up new venues of feminist discourse.In this paper we sketch the main feminist lines of argumentation regarding motherhood and reproduction since the 1970s, and we identify specific shifts in their recurrent issues. We argue that an essential contribution of feminism to the understanding of motherhood as a structuring category has been its insis- tence on the distinction between biological and social motherhood. Feminist discourse shows how ART has further decomposed biological motherhood and has altered the meaning of motherhood and reproduction. Feminist analysis maintains that despite the rhetoric of choice surrounding ART, these technolo- gies have not increased women's reproductive freedom. The decomposition of biological motherhood, the medical, legal, and commercial development of re- production, and the change in the social perception of motherhood have rather established new forms of control over female reproduction.
Resumo:
The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.
Resumo:
BACKGROUND: Clinical practice does not always reflect best practice and evidence, partly because of unconscious acts of omission, information overload, or inaccessible information. Reminders may help clinicians overcome these problems by prompting the doctor to recall information that they already know or would be expected to know and by providing information or guidance in a more accessible and relevant format, at a particularly appropriate time. OBJECTIVES: To evaluate the effects of reminders automatically generated through a computerized system and delivered on paper to healthcare professionals on processes of care (related to healthcare professionals' practice) and outcomes of care (related to patients' health condition). SEARCH METHODS: For this update the EPOC Trials Search Co-ordinator searched the following databases between June 11-19, 2012: The Cochrane Central Register of Controlled Trials (CENTRAL) and Cochrane Library (Economics, Methods, and Health Technology Assessment sections), Issue 6, 2012; MEDLINE, OVID (1946- ), Daily Update, and In-process; EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ); EPOC Specialised Register, Reference Manager, and INSPEC, Engineering Village. The authors reviewed reference lists of related reviews and studies. SELECTION CRITERIA: We included individual or cluster-randomized controlled trials (RCTs) and non-randomized controlled trials (NRCTs) that evaluated the impact of computer-generated reminders delivered on paper to healthcare professionals on processes and/or outcomes of care. DATA COLLECTION AND ANALYSIS: Review authors working in pairs independently screened studies for eligibility and abstracted data. We contacted authors to obtain important missing information for studies that were published within the last 10 years. For each study, we extracted the primary outcome when it was defined or calculated the median effect size across all reported outcomes. We then calculated the median absolute improvement and interquartile range (IQR) in process adherence across included studies using the primary outcome or median outcome as representative outcome. MAIN RESULTS: In the 32 included studies, computer-generated reminders delivered on paper to healthcare professionals achieved moderate improvement in professional practices, with a median improvement of processes of care of 7.0% (IQR: 3.9% to 16.4%). Implementing reminders alone improved care by 11.2% (IQR 6.5% to 19.6%) compared with usual care, while implementing reminders in addition to another intervention improved care by 4.0% only (IQR 3.0% to 6.0%) compared with the other intervention. The quality of evidence for these comparisons was rated as moderate according to the GRADE approach. Two reminder features were associated with larger effect sizes: providing space on the reminder for provider to enter a response (median 13.7% versus 4.3% for no response, P value = 0.01) and providing an explanation of the content or advice on the reminder (median 12.0% versus 4.2% for no explanation, P value = 0.02). Median improvement in processes of care also differed according to the behaviour the reminder targeted: for instance, reminders to vaccinate improved processes of care by 13.1% (IQR 12.2% to 20.7%) compared with other targeted behaviours. In the only study that had sufficient power to detect a clinically significant effect on outcomes of care, reminders were not associated with significant improvements. AUTHORS' CONCLUSIONS: There is moderate quality evidence that computer-generated reminders delivered on paper to healthcare professionals achieve moderate improvement in process of care. Two characteristics emerged as significant predictors of improvement: providing space on the reminder for a response from the clinician and providing an explanation of the reminder's content or advice. The heterogeneity of the reminder interventions included in this review also suggests that reminders can improve care in various settings under various conditions.
Resumo:
This study was designed to check for the equivalence of the ZKPQ-50-CC (Spanish and French versions) through Internet on-line (OL) and paper and pencil (PP) answer format. Differences in means and devia- tions were significant in some scales, but effect sizes are minimal except for Sociability in the Spanish sample. Alpha reliabilities are also very similar in both versions with no significant differences between formats. A robust factorial structure was found for the two formats and the average congruency coefficients were 0.98. The goodness-of-fit indexes obtained by confirmatory factorial analysis are very similar to those obtained in the ZKPQ-50-CC validation study and they do not differ between the two formats. The multi-group analysis confirms the equivalence among the OL-PP formats in both countries. These results in general support the validity and reliability of the Internet as a method in investigations using the ZKPQ-50-CC.
Resumo:
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.