75 resultados para Acquisition board
Resumo:
Stimulated echoes are widely used for imaging functional tissue parameters such as diffusion coefficient, perfusion, and flow rates. They are potentially interesting for the assessment of various cardiac functions. However, severe limitations of the stimulated echo acquisition mode occur, which are related to the special dynamic properties of the beating heart and flowing blood. To the well-known signal decay due to longitudinal relaxation and through-plane motion between the preparation and the read-out period of the stimulated echoes, additional signal loss is often observed. As the prepared magnetization is fixed with respect to the tissue, this signal loss is caused by the tissue deformation during the cardiac cycle, which leads to a modification of the modulation frequency of the magnetization. These effects are theoretically derived and corroborated by phantom and in vivo experiments.
Resumo:
Objectives: Recent population genetic studies suggest that the Staphylococcal Chromosome Cassettes mec (SCCmec) was acquired at a global scale much more frequently than previously thought. We hypothesized that such acquisitions can also be observed at a local level. In the present study, we aimed at investigating the diversity of SCCmec in a local MRSA population, where the dissemination of four MRSA clones has been observed (JCM 2007, 45: 3729). Methods: All the MRSA isolates (one per patient) recovered in the Vaud canton of Switzerland from January 2005 to December 2008 were analyzed in this study. We used the Double Locus Sequence Typing (DLST) method, based on clfB and spa loci, and the e-BURST algorithm to group the types with one allele in common (i.e. clone). To increase the discriminatory power of the DLST method, a third polymorphic marker (clfA) was further analyzed on a sub-sample of isolates. The SCCmec type of each isolate was determined with the first two PCRs of the Kondo scheme. Results: DLST analysis indicated that 1884/2036 isolates (92.5%) belong to the four predominant clones. A majority of isolates in each clone harboured an identical SCCmec type: 61/64 (95%) isolates to DLST clone 1−1 SCCmec IV, 1282/1323 (97%) to clone 2−2 SCCmec II, 237/288 (82%) to clone 3−3 SCCmec IV, and 192/209 (92%) to clone 4−4 SCCmec I. Unexpectedly, different SCCmec types were present in a single predominant DLST clone: SCCmec V plus one unusual type in 3 isolates of clone 1−1; SCCmec I, IV, V, VI plus two unusual types in 41 isolates of clone 2−2; SCCmec I, II, VI plus three unusual types in 51 isolates of clone 3−3; and SCCmec II, IV, V plus one unusual type in 17 isolates of clone 4−4. Interestingly, adding a third locus generally did not change the classification of incongruent SCCmec types, suggesting that these SCCmec elements have been acquired locally during the dissemination of the clones. Conclusion: Although the SCCmec diversity within clones was relatively low at a local level, a significant proportion of isolates with different SCCmec have been identified in the four major clones. This suggests that the local acquisition of SCCmec elements is not a rare event and illustrates the great capacity of S. aureus to quickly adapt to its environment by acquiring new genetic elements.
Copper acquisition by the SenC protein regulates aerobic respiration in Pseudomonas aeruginosa PAO1.
Resumo:
Aerobic respiration of Pseudomonas aeruginosa involves four terminal oxidases belonging to the heme-copper family (that is, three cytochrome c oxidases and one quinol oxidase) plus one copper-independent, cyanide-insensitive quinol oxidase (CIO). The PA0114 gene encoding an SCO1/SenC-type protein, which is known to be important for copper delivery to cytochrome c in yeast, Rhodobacter spp. and Agrobacterium tumefaciens, was found to be important for copper acquisition and aerobic respiration in P. aeruginosa. A PA0114 (senC) mutant grew poorly in low-copper media and had low cytochrome cbb(3)-type oxidase activity, but expressed CIO at increased levels, by comparison with the wild-type PAO1. Addition of copper reversed these phenotypes, suggesting that periplasmic copper capture by the SenC protein helps P. aeruginosa to adapt to copper deprivation.
Resumo:
When the US Preventive Services Task Force (USPSTF) in 2009 recommended against universal breast cancer screening with mammography in women aged 40 to 49 years, some scientists, radiologists, politicians, and patients strongly objected. The controversy has been called the "mammography wars." The latest chapter in these wars comes from the Swiss Medical Board, which is mandated by the Conference of Health Ministers of the Swiss Cantons, the Swiss Medical Association, and the Swiss Academy of Medical Sciences to conduct health technology assessments. In a February 2014 report, the Swiss Medical Board stated that new systematic mammography screening programs should not be introduced, irrespective of the age of the women, and that existing programs should be discontinued. The board's main argument was that the absolute reduction in breast cancer mortality was low and that the adverse consequences of the screening were substantial. The absolute risk reduction in breast cancer mortality has been estimated by the board at 0.16% for women screened during 6.2 years and followed-up over 13 years, based on the results of a recent Cochrane Review. The adverse consequences include falsepositive test results, overdiagnosis and overtreatment of patients, and high costs, including the expense of follow-up testing and procedures.
Resumo:
Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.
Resumo:
PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.
Resumo:
Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.
Resumo:
BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.