364 resultados para PAIN MEASUREMENT
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
Chronic pain refractory to medical therapy poses a therapeutic challenge. The repetitive Transcranial Magnetic Stimulation (rTMS) and transcranial Direct Current Stimulation (tDCS) modulate brain activity offering a new approach. Current evidence suggests a potential therapeutic efficacy of motor cortex stimulation for the treatment of pain, but does not (yet) support their recommendation for clinical practice. These methods allow to deepen our knowledge in the pathophysiology of chronic pain while providing new therapeutic approaches.
Resumo:
BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
Combining bacterial bioreporters with microfluidics systems holds great promise for in-field detection of chemical or toxicity targets. Recently we showed how Escherichia coli cells engineered to produce a variant of green fluorescent protein after contact to arsenite and arsenate can be encapsulated in agarose beads and incorporated into a microfluidic chip to create a device for in-field detection of arsenic, a contaminant of well known toxicity and carcinogenicity in potable water both in industrialized and developing countries. Cell-beads stored in the microfluidics chip at -20°C retained inducibility up to one month and we were able to reproducibly discriminate concentrations of 10 and 50 μg arsenite per L (the drinking water standards for European countries and the United States, and for the developing countries, respectively) from the blank in less than 200 minutes. We discuss here the reasons for decreasing bioreporter signal development upon increased storage of cell beads but also show how this decrease can be reduced, leading to a faster detection and a longer lifetime of the device.
Resumo:
Anal pain is a common reason for consultation, whose etiology is varied and should not be limited to the hemorrhoidal disease. The purpose of this article is to conduct a review of the literature on anorectal pathologies most frequently encountered and make recommendations regarding their management.
Resumo:
RESUME Objectifs. Évaluer la prévalence de maladie coronarienne chez les patients diabétiques de type 2 asymptomatiques ou avec angor atypique selon les recommandations américaines de l'American Diabetes Association et de l'American College of Cardiology. Méthodes. Cent cinquante-quatre patients diabétiques de type 2 asymptomatiques ou avec angor atypique et présentant au minimum 2 facteurs de risque cardio-vasculaires additionnels ont été dépistés par échocardiographie de stress (71%, n=109), scintigraphie myocardique de perfusion (26%, n=40) ou l'association des 2 examens (3%, n=5). Résultats. L'échocardiographie de stress s'est révélée positive chez 16 patients (14%) et 14 ont eu une coronarographie révélant des sténoses significatives chez 12 (86%). La scintigraphie myocardique de perfusion était positive chez 16 patients (36%). Huit patients ont eu une coronarographie et 4 (50%) présentaient des sténoses significatives. Au total, 31 patients (20%) ont montré des signes d'ischémie lors de l'examen non-invasif et 15 (10%) ont présenté des sténoses significatives à la coronarographie. Les facteurs prédictifs indépendants de la maladie coronarienne étaient le tabagisme (OR 6.5, p=0.05), la microalbuminurie (OR 3.9, p=0.03), ainsi que les souffles fémoraux (OR 17.1, p=0.008). Conclusions. En suivant les recommandations américaines, un patient sur cinq présentait une ischémie lors des examens non-invasifs, tandis que 1 sur 10 avait des sténoses significatives à la coronarographie. L'analyse multivariée suggère que des marqueurs des complications micro- et macro-vasculaires en combinaison avec des facteurs de risque cardio-vasculaire classiques pourraient améliorer le pouvoir diagnostic de ces recommandations. SUMMARY Aims. We evaluated the prevalence of coronary artery disease in asymptomatic and atypical chest pain type 2 diabetic patients according to the American Diabetes Association and American College of Cardiology guidelines. Methods. Asymptomatic or atypical chest pain type 2 diabetic patients (n=154), with at least two additional cardiovascular risk factors, were screened for coronary artery disease using stress echocardiography (71%, n=109), myocardial perfusion imaging (26%, n=40) or both (3%, n=5). Results. Stress echocardiography was positive in 16 patients (14%) and 14 had a coronary angiography, revealing significant stenoses in 12 (86%). Myocardial perfusion imaging was positive in 16 patients (36%). Eight patients underwent angiography and 4 (50%) presented significant stenoses. Overall, 31 patients (20%) demonstrated signs of ischemia on non-invasive tests and 15 (10%) presented significant stenoses on coronary angiography. Independent predictors of coronary artery disease were smoking (OR 6.5, p=0.05), microalbuminuria (OR 3.9, p=0.03) and femoral murmur (OR 17.1, p=0.008). Conclusions. Following the guidelines, one in five diabetic patient presented ischemia on noninvasive tests, while one in ten presented significant coronary stenoses. Multivariate analysis suggests that adding markers of micro- and macro-vascular complications to classical cardiovascular risk factors may enhance the diagnostic efficiency of the guidelines.
Resumo:
Results of 14 randomized controlled trials of acupuncture for chronic pain were pooled in a meta-analysis and analysed in three subgroups according to site of pain; and in two subgroups each according to type to trial, type of treatment, type of control, 'blindness' of participating agents, trial size, and type of journal in which results were published. While few individual trials had statistically significant results, pooled results of many subgroups attained statistical significance in favour of acupuncture. Various potential sources of bias, including problems with blindness, precluded a conclusive finding although most results apparently favoured acupuncture.
Resumo:
Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest.
Resumo:
BACKGROUND: LEOPARD syndrome (LS) belongs to the family of neuro-cardio-facio-cutaneous syndromes, which include Neurofibromatosis-1 (NF1), Noonan syndrome, Costello Syndrome, cardio-facio-cutaneous syndrome, Noonan-like syndrome with loose anagen hair and Legius syndrome. These conditions are caused by mutations in genes encoding proteins involved in the RAS-MAPK cellular pathway. Clinical heterogeneity and phenotype overlaps across those different syndromes is already recognized. CASE PRESENTATION: We hereby report a heterozygous de novo mutation in the PTPN11 gene (c.1403C > T) manifesting with a clinical picture of LS during childhood, and later development of neuropathic pain with hypertrophic plexi, which are typically observed in NF1 but have not been reported in LS. CONCLUSION: LS caused by PTPN11 mutations may be associated with hypertrophic roots and plexi. Consequently, clinicians should be aware of the possible development of neuropathic pain and consider specific diagnostic work-up and management.