405 resultados para ULTRASONOGRAPHIC IMAGING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last two decades, Atomic Force Microscopy (AFM) has emerged as the tool of choice to image living organisms in a near-physiological environment. Whereas fluorescence microscopy techniques allow labeling and tracking of components inside cells and the observation of dynamic processes, AFM is mainly a surface technique that can be operated on a wide range of substrates including biological samples. AFM enables extraction of topographical, mechanical and chemical information from these samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current therapeutic strategies against glioblastoma (GBM) have failed to prevent disease progression and recurrence effectively. The part played by molecular imaging (MI) in the development of novel therapies has gained increasing traction in recent years. For the first time, using expertise from an integrated multidisciplinary group of authors, herein we present a comprehensive evaluation of state-of-the-art GBM imaging and explore how advances facilitate the emergence of new treatment options. We propose a novel next-generation treatment paradigm based on the targeting of multiple hallmarks of cancer evolution that will heavily rely on MI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prognostic significance of magnetic resonance imaging (MRI) in the neonatal period was studied prospectively in 43 term infants with perinatal asphyxia. MRI was performed between 1 and 14 days after birth with a high field system (2.35 Tesla). Neurodevelopmental outcome was assessed by a standardized neurological examination and the Griffiths developmental test at a mean age of 18.9 months. The predictive value of the various MRI patterns was as follows: Severe diffuse brain injury (pattern AII+III; n = 7) and lesions of thalamus and basal ganglia (pattern C; n = 5) were strongly associated with poor outcome and greatly reduced head growth. Mild diffuse brain injury (pattern AI; n = 7), parasagittal lesions (B; n = 7), periventricular hyperintensity (D; n = 2), focal brain necrosis and hemorrhage (E; n = 3) and periventricular hypointense stripes (on T2-weighted images; F; n = 3) led in one third of the infants to minor neurological disturbances and mild developmental delay. Infants with normal MRI findings (G; n = 9) developed normally with the exception of one infant who was mildly delayed at 18 months. The results indicate that MRI examination during the first two weeks of life is of prognostic significance in term infants suffering from perinatal asphyxia. Severe hypoxic-ischemic brain lesions were associated highly significantly with poor neuro-developmental outcome, whereas infants with inconspicuous MRI developed normally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vascular properties of large vessels in the obese have not been adequately studied. We used cardiovascular magnetic resonance imaging to quantify the cross-sectional area and elastic properties of the ascending thoracic and abdominal aorta in 21 clinically healthy obese young adult men and 25 men who were age-matched lean controls. Obese subjects had greater maximal cross-sectional area of the ascending thoracic aorta (984 +/- 252 vs 786 +/- 109 mm(2), p <0.01) and of the abdominal aorta (415 +/- 71 vs 374 +/- 51 mm(2), p <0.05). When indexed for height the differences persisted, but when indexed for body surface area, a significant difference between groups was found only for the maximal abdominal aortic cross-sectional area. The obese subjects also had decreased abdominal aortic elasticity, characterized by 24% lower compliance (0.0017 +/- 0.0004 vs 0.0021 +/- 0.0005 mm(2)/kPa/mm, p <0.01), 22% higher stiffness index beta (6.0 +/- 1.5 vs 4.9 +/- 0.7, p <0.005), and 41% greater pressure-strain elastic modulus (72 +/- 25 vs 51 +/- 9, p <0.005). At the ascending thoracic aorta, only the pressure-strain elastic modulus was different between obese and lean subjects (85 +/- 42 vs 65 +/- 26 kPa, respectively; p <0.05), corresponding to a 31% difference-but arterial compliance and stiffness index were not significantly different between groups. In clinically healthy young adult obese men, obesity is associated with increased cross-sectional aortic area and decreased aortic elasticity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To improve the traditional Nyquist ghost correction approach in echo planar imaging (EPI) at high fields, via schemes based on the reversal of the EPI readout gradient polarity for every other volume throughout a functional magnetic resonance imaging (fMRI) acquisition train. MATERIALS AND METHODS: An EPI sequence in which the readout gradient was inverted every other volume was implemented on two ultrahigh-field systems. Phantom images and fMRI data were acquired to evaluate ghost intensities and the presence of false-positive blood oxygenation level-dependent (BOLD) signal with and without ghost correction. Three different algorithms for ghost correction of alternating readout EPI were compared. RESULTS: Irrespective of the chosen processing approach, ghosting was significantly reduced (up to 70% lower intensity) in both rat brain images acquired on a 9.4T animal scanner and human brain images acquired at 7T, resulting in a reduction of sources of false-positive activation in fMRI data. CONCLUSION: It is concluded that at high B(0) fields, substantial gains in Nyquist ghost correction of echo planar time series are possible by alternating the readout gradient every other volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Astrocytes fulfill a central role in regulating K+ and glutamate, both released by neurons into the extracellular space during activity. Glial glutamate uptake is a secondary active process that involves the influx of three Na+ ions and one proton and the efflux of one K+ ion. Thus, intracellular K+ concentration ([K+]i) is potentially influenced both by extracellular K+ concentration ([K+]o) fluctuations and glutamate transport in astrocytes. We evaluated the impact of these K+ ion movements on [K+]i in primary mouse astrocytes by microspectrofluorimetry. We established a new noninvasive and reliable approach to monitor and quantify [K+]i using the recently developed K+ sensitive fluorescent indicator Asante Potassium Green-1 (APG-1). An in situ calibration procedure enabled us to estimate the resting [K+]i at 133±1 mM. We first investigated the dependency of [K+]i levels on [K+]o. We found that [K+]i followed [K+]o changes nearly proportionally in the range 3-10 mM, which is consistent with previously reported microelectrode measurements of intracellular K+ concentration changes in astrocytes. We then found that glutamate superfusion caused a reversible drop of [K+]i that depended on the glutamate concentration with an apparent EC50 of 11.1±1.4 µM, corresponding to the affinity of astrocyte glutamate transporters. The amplitude of the [K+]i drop was found to be 2.3±0.1 mM for 200 µM glutamate applications. Overall, this study shows that the fluorescent K+ indicator APG-1 is a powerful new tool for addressing important questions regarding fine [K+]i regulation with excellent spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary coronary magnetic resonance angiography techniques suffer from signal-to-noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding to improve SNR seems counterintuitive, it can be exploited by reducing the number of radiofrequency excitations during the acquisition window while lowering the signal readout bandwidth, therefore improving the radiofrequency receive to radiofrequency transmit duty cycle. Under certain conditions, this leads to improved SNR. The use of sensitivity encoding for improved SNR in three-dimensional coronary magnetic resonance angiography is investigated using numerical simulations and an in vitro and an in vivo study. A maximum 55% SNR enhancement for coronary magnetic resonance angiography was found both in vitro and in vivo, which is well consistent with the numerical simulations. This method is most suitable for spoiled gradient echo coronary magnetic resonance angiography in which a high temporal and spatial resolution is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract : Matrix metalloproteinases (MMPs) are thought to play a major role in the tumor dissemination process as they degrade all components of the extracellular matrix. However, failure of clinical trials testing broad MMP inhibitors in cancer led to the consensus that a better understanding of the MMP biology was required. Using intravital multiphoton laser scanning microscopy, we developed an in vivo model to observe tumor dissemination and extracellular matrix remodeling in real time. We show that the matrix-modifying hormone relaxin increases tumor associated fibroblast interaction with collagen fibers by inducing integrin beta-1 expression. This causes changes in the collagen network that are mediated by MMP-8 and MT1-MMP. Also, we show that MMP-mediated collagen remodeling in vivo requires a direct contact between stationary tumor associated fibroblasts (TAFs) and collagen fibers. As MMPs are expressed in the tumor and stromal compartment of breast cancers we determined the importance of Membrane-type 1 MMP (MT1-MMP) from each compartment for cancer progression. We find that tumor-MT1-MMP promotes the invasion of the blood vasculature and blood-borne metastasis in vivo by enhancing tumor cell migration and endothelial basement membrane degradation. Interestingly, stromal-MT1-MMP cannot compensate for the lack of tumor-MT1-MMP but promotes peritumor collagen I remodeling. Thus, the function of MT1-MMP is context dependent and we identify the different but complementary roles of tumor and stromal MT1-MMP for tumor dissemination. Finally, we translate our preclinical findings in to human breast cancer samples. We show that tumor-MT1-MMP expression correlates with tumor invasion of the blood vasculature in ER-PR-HER2- breast cancers and that MT1-MMP expression increases with cancer progression. MT1-MMP could thus represent an interesting therapeutic target for the prevention of blood vasculature invasion in these tumors. Resumé : Les matrix metalloproteinases (MMPs) semblent jouer un rôle majeur pour la dissémination tumorale en raison de leur capacité à dégrader l'ensemble des composants de la matrice extracellulaire (MEC). Néanmoins, les résultats décevants des études cliniques testant les inhibiteurs des MMP ont conduit à la notion qu'une compréhension plus précise de la biologie des MMP était requise. Dans ce travail de thèse, nous avons développé un modèle murin qui permet d'observer simultanément la dissémination tumorale ainsi que les modifications de la MEC en temps réel. Nous démontrons que le traitement de tumeurs par l'hormone relaxin augmente l'interaction des fibroblastes tumoraux avec les fibres de collagène via l'intégrine beta-1. Nous montrons que cette interaction favorise et est nécessaire à la dégradation des fibres de collagène par MMP-8 et MT1-MMP. Ensuite, étant donné que les MMPs sont exprimées dans les cellules tumorales et stromales des cancers du sein, nous nous sommes intéressés au rôle de la MMP membranaire type 1 (MT1-MMP) exprimée dans chacun de ces compartiments. Nous démontrons que MT1-MMP dérivant des cellules tumorales favorise leur invasion dans les vaisseaux sanguins par la dégradation de la membrane basale vasculaire. De manière inattendue, nous montrons que l'expression de MT1-MMP par le compartiment stromal ne peut compenser le manque de MT1-MMP dans le compartiment tumoral. Néanmoins, nos résultats prouvent que MT1-MMP dérivant du compartiment stromal est impliqué dans la dégradation de collagène peritumorale. La fonction de la protéine MT1-MMP varie donc selon le compartiment tumoral d'origine. Finalement, nous avons testé nos résultats pré cliniques chez l'humain. Dans des biopsies de cancer du sein nous montrons une corrélation entre l'expression de MT1-MMP dans les cellules tumorales et l'invasion de vaisseaux sanguins par des tumeurs ER-PR-HER2-. MT1-MMP pourrait donc être une cible intéressante pour la prévention de dissémination vasculaire de ces tumeurs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A published formula containing minimal aortic cross-sectional area and the flow deceleration pattern in the descending aorta obtained by cardiovascular magnetic resonance predicts significant coarctation of the aorta (CoA). However, the existing formula is complicated to use in clinical practice and has not been externally validated. Consequently, its clinical utility has been limited. The aim of this study was to derive a simple and clinically practical algorithm to predict severe CoA from data obtained by cardiovascular magnetic resonance. Seventy-nine consecutive patients who underwent cardiovascular magnetic resonance and cardiac catheterization for the evaluation of native or recurrent CoA at Children's Hospital Boston (n = 30) and the University of California, San Francisco (n = 49), were retrospectively reviewed. The published formula derived from data obtained at Children's Hospital Boston was first validated from data obtained at the University of California, San Francisco. Next, pooled data from the 2 institutions were analyzed, and a refined model was created using logistic regression methods. Finally, recursive partitioning was used to develop a clinically practical prediction tree to predict transcatheter systolic pressure gradient ≥ 20 mm Hg. Severe CoA was present in 48 patients (61%). Indexed minimal aortic cross-sectional area and heart rate-corrected flow deceleration time in the descending aorta were independent predictors of CoA gradient ≥ 20 mm Hg (p <0.01 for both). A prediction tree combining these variables reached a sensitivity and specificity of 90% and 76%, respectively. In conclusion, the presented prediction tree on the basis of cutoff values is easy to use and may help guide the management of patients investigated for CoA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the problem of intensity inhomogeneity athigh magnetic field on magnetic resonance images isaddressed. Specifically, rat brain images at 9.4Tacquired with a surface coil are bias corrected. Wepropose a low- pass frequency model that takes intoaccount not only background-object contours but alsoother important contours inside the image. Twopre-processing filters are proposed: first, to create avolume of interest without contours, and second, toextrapolate the image values of such masked area to thewhole image. Results are assessed quantitatively andvisually in comparison to standard low pass filterapproach, and they show as expected better accuracy inenhancing image intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The DEFUSE (n_74) and EPITHET (n_101) studies have in common that a baseline MRI was obtained prior to treatment (tPA in DEFUSE; tPA or placebo in EPITHET) in the 3-6 hour time-window. There were however important methodological differences between the studies. A standardized reanalysis of pooled data was undertaken to determine the effect of these differences on baseline characteristics and study outcomes. Methods: To standardize the studies 1) the DWI and PWI source images were reprocessed and segmented using automated image processing software (RAPID); 2) patients were categorized according to their baseline MRI profile as either Target Mismatch (PWITmax_6/DWI ratio_ 1.8 and an absolute mismatch _15mL), Malignant (DWI or PWITmax_10 lesion _ 100 mL), or No Mismatch. 3) favorable clinical response was defined as NIHSS score of 0-1 or a _8 points improvement on the NIHSSS at day 90. Results: Prior to standardization there was no difference in the proportion of Target Mismatch patients between EPITHET and DEFUSE (54% vs 49%, p_0.6), but the EPITHET study had more patients with the Malignant profile than DEFUSE (35% vs 9%, p_0.01) and fewer patients that had No Mismatch (11% vs 42%, p_0.01). These differences in baseline MRI profiles between EPITHET and DEFUSE were largely eliminated by standardized processing of PWI and DWI images with RAPID software (Target Mismatch 49% vs 48%; Malignant 15% vs 8%; No Mismatch 36% vs 25%; p_NS for all comparisons) Reperfusion was strongly associated with a favorable clinical response in mismatch patients (figure). This relationship was not affected by the standardization procedures (pooled odds ratio of 8.8 based on original data and 6.6 based on standardized data). Conclusion: Standardization of image analyses procedures in acute stroke is important as non-standardized techniques introduce significant variability in DWI and PWI imaging characteristics. Despite methodological differences, the DEFUSE and EPITHET studies show a consistent and robust association between reperfusion and favorable clinical response in Target Mismatch patients regardless of standardization. These data support an RCT of iv tPA in the 3-6 hour time-window for Target Mismatch patients identified using RAPID.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.