67 resultados para sieve-tray extraction column


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: In sexual assault cases, autosomal DNA analysis of gynecological swabs is a challenge, as the presence of a large quantity of female material may prevent the detection of the male DNA. A solution to this problem is differential DNA extraction, but as there are different protocols, it was decided to test their efficiency on simulated casework samples. Four difficult samples were sent to the nine Swiss laboratories active in the forensic genetics. They used their routine protocols to separate the epithelial cell fraction, enriched with the non-sperm DNA, from the sperm fraction. DNA extracts were then sent to the organizing laboratory for analysis. Estimates of male to female DNA ratio without differential DNA extraction ranged from 1:38 to 1:339, depending on the semen used to prepare the samples. After differential DNA extraction, most of the ratios ranged from 1:12 to 9:1, allowing the detection of the male DNA. Compared to direct DNA extraction, cell separation resulted in losses of 94-98% of the male DNA. As expected, more male DNA was generally present in the sperm than in the epithelial cell fraction. However, for about 30% of the samples, the reverse trend was observed. The recovery of male and female DNA was highly variable depending on the laboratories. Experimental design similar to the one used in this study may help for local protocol testing and improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: A rapid and simple HPLC-MS method was developed for the simultaneousdetermination of antidementia drugs, including donepezil, galantamine, rivastigmineand its major metabolite NAP 226 - 90, and memantine, for TherapeuticDrug Monitoring (TDM). In the elderly population treated with antidementiadrugs, the presence of several comorbidities, drug interactions resulting frompolypharmacy, and variations in drug metabolism and elimination, are possiblefactors leading to the observed high interindividual variability in plasma levels.Although evidence for the benefit of TDM for antidementia drugs still remains tobe demonstrated, an individually adapted dosage through TDM might contributeto minimize the risk of adverse reactions and to increase the probability of efficienttherapeutic response. Methods: A solid-phase extraction procedure with amixed-mode cation exchange sorbent was used to isolate the drugs from 0.5 mL ofplasma. The compounds were analyzed on a reverse-phase column with a gradientelution consisting of an ammonium acetate buffer at pH 9.3 and acetonitrile anddetected by mass spectrometry in the single ion monitoring mode. Isotope-labeledinternal standards were used for quantification where possible. The validatedmethod was used to measure the plasma levels of antidementia drugs in 300patients treated with these drugs. Results: The method was validated accordingto international standards of validation, including the assessment of the trueness(-8 - 11 %), the imprecision (repeatability: 1-5%, intermediate imprecision:2 - 9 %), selectivity and matrix effects variability (less than 6 %). Furthermore,short and long-term stability of the analytes in plasma was ascertained. Themethod proved to be robust in the calibrated ranges of 1 - 300 ng/mL for rivastigmineand memantine and 2 - 300 mg/mL for donepezil, galantamine and NAP226 - 90. We recently published a full description of the method (1). We found ahigh interindividual variability in plasma levels of these drugs in a study populationof 300 patients. The plasma level measurements, with some preliminaryclinical and pharmacogenetic results, will be presented. Conclusion: A simpleLC-MS method was developed for plasma level determination of antidementiadrugs which was successfully used in a clinical study with 300 patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure using a chirobiotic V column is presented which allows separation of the enantiomers of citalopram and its two N-demethylated metabolites, and of the internal standard, alprenolol, in human plasma. Citalopram, demethylcitalopram and didemethylcitalopram, as well as the internal standard, were recovered from plasma by liquid-liquid extraction. The limits of quantification were found to be 5 ng/ml for each enantiomer of citalopram and demethylcitalopram, and 7.5 ng/ml for each enantiomer of didemethylcitalopram. Inter- and intra-day coefficients of variation varied from 2.4% to 8.6% for S- and R-citalopram, from 2.9% to 7.4% for S- and R-demethylcitalopram, and from 5.6% to 12.4% for S- and R- didemethylcitalopram. No interference was observed from endogenous compounds following the extraction of plasma samples from 10 different patients treated with citalopram. This method allows accurate quantification for each enantiomer and is, therefore, well suited for pharmacokinetic and drug interaction investigations. The presented method replaces a previously described highly sensitive and selective high-performance liquid chromatography procedure using an acetylated 3-cyclobond column which, because of manufactural problems, is no longer usable for the separation of the enantiomers of citalopram and its demethylated metabolites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the NE part of the Aiguilles Rouges Massif near Martigny, at the eastern contact of the Variscan Vallorcine granite to adjacent gneisses, a series of pitchblende (UO2)-veins occur. This paper determines the level of enrichment and mobility of uranium in soils situated in the vicinity of such a UO2-vein 7 km west of Martigny. Within an area of 50 x 100 m, situated on a relatively steep slope and characterized by a strong gramma-ray anomaly, six soil profiles including their plant cover and a reference soil profile outside the influence of the UO2-vein have been examined. The soil shows pH-values between 4 and 5 and is colluvial. The applied analytical methods for the metal contents include extraction methods, common for soil studies, and bulk analysis performed with X-ray fluorescence and ICP-MS. Uranium contents found in the uppermost 20 cm of the soil profiles vary from 2,500 ppm close to the vein to 15 ppm at the lowermost point of the study area. The reference soil has around 3 ppm uranium. At greater depth (20 to 40 cm) the U-content decreases to about half of the surface values, indicating a vertical transport of uranium within the soil profile. No systematic dependance of uranium-contents to grain size (amount of clay) nor to the amount of organic matter has been found. However, the good correlation between uranium and free iron oxide concentration suggests adsorption of uranium on iron oxy-hydroxides. The ashes of grass and mosses contain up to 90 ppm U, the blueberry and redwood only up to 3 ppm. Our observations suggest that at the surface the uranium is transported by downhill creep (solifluxion) of uranium-rich rock fragments. Liberated by oxidation of the uppermost fragments in a given soil column, the uranium migrates vertically until the conditions are favourable to adsorption onto Fe-oxy-hydroxides. However, as high U-contents of local surface water show, this adsorption does not lead to a significant retention of the uranium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A HPLC method is presented for the identification and quantification in plasma and urine of beta-adrenergic receptor antagonists (betaxolol, carteolol, metipranolol, and timolol) commonly prescribed in ophthalmology. An extraction method is described using pindolol as an internal standard. An RSIL 10 micron column was used. The lower detection limits of the beta-blockers were found to be 4-27 ng/ml. This method is simple, rapid and sensitive; moreover, it allows the determination of 8 other beta-blockers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the forensic protocol recently developed by Qiagen for the QIAsymphony automated DNA extraction platform. Samples containing low amounts of DNA were specifically considered, since they represent the majority of samples processed in our laboratory. The analysis of simulated blood and saliva traces showed that the highest DNA yields were obtained with the maximal elution volume available for the forensic protocol, that is 200 ml. Resulting DNA extracts were too diluted for successful DNA profiling and required a concentration. This additional step is time consuming and potentially increases inversion and contamination risks. The 200 ml DNA extracts were concentrated to 25 ml, and the DNA recovery estimated with real-time PCR as well as with the percentage of SGM Plus alleles detected. Results using our manual protocol, based on the QIAamp DNA mini kit, and the automated protocol were comparable. Further tests will be conducted to determine more precisely DNA recovery, contamination risk and PCR inhibitors removal, once a definitive procedure, allowing the concentration of DNA extracts from low yield samples, will be available for the QIAsymphony.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Exposer une nouvelle technique permettant le retrait de ciment extra-vertebral par fuite accidentelle lors du retrait du matériel. Matériels et méthodes: Nous injectons le ciment lorsque sa densité est celle d'une pâte dentifrice pour éviter les passages vasculaires. Lorsque la vertèbre est parfaitement remplie,nous patientons quelques minutes pour éviter la fuite de ciment le long du trajet (environ 4 a 6 cc en moyenne par vertèbre sont injectés). Malgré ces précautions,une fuite de ciment peut survenir lors du retrait du trocart. Cette complication est rare lorsque l'on prend les précautions nécessaires. Cependant, si la pressionintra-vertébrale est importante, le ciment peut être aspiré en dehors de la vertèbre. Résultats: L'aiguille du trocart est retirée pour être remplacée par une pince d'endoscopie 13 gauges. Sous guidage scopique, l'extraction se fait sous contrôle continu ; lapince retirant la fuite de ciment. Conclusion: La connaissance de cette intervention peut être très utile pour les équipes de radiologie interventionnelle , d'orthopédie et de neurochirurgie réalisant desvertébroplasties, pouvant être confrontées à ce type de problèmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed for the simultaneous quantification in human plasma of all selective serotonin reuptake inhibitors (citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline) and their main active metabolites (desmethyl-citalopram and norfluoxetine). A stable isotope-labeled internal standard was used for each analyte to compensate for the global method variability, including extraction and ionization variations. After sample (250μl) pre-treatment with acetonitrile (500μl) to precipitate proteins, a fast solid-phase extraction procedure was performed using mixed mode Oasis MCX 96-well plate. Chromatographic separation was achieved in less than 9.0min on a XBridge C18 column (2.1×100mm; 3.5μm) using a gradient of ammonium acetate (pH 8.1; 50mM) and acetonitrile as mobile phase at a flow rate of 0.3ml/min. The method was fully validated according to Société Française des Sciences et Techniques Pharmaceutiques protocols and the latest Food and Drug Administration guidelines. Six point calibration curves were used to cover a large concentration range of 1-500ng/ml for citalopram, desmethyl-citalopram, paroxetine and sertraline, 1-1000ng/ml for fluoxetine and fluvoxamine, and 2-1000ng/ml for norfluoxetine. Good quantitative performances were achieved in terms of trueness (84.2-109.6%), repeatability (0.9-14.6%) and intermediate precision (1.8-18.0%) in the entire assay range including the lower limit of quantification. Internal standard-normalized matrix effects were lower than 13%. The accuracy profiles (total error) were mainly included in the acceptance limits of ±30% for biological samples. The method was successfully applied for routine therapeutic drug monitoring of more than 1600 patient plasma samples over 9 months. The β-expectation tolerance intervals determined during the validation phase were coherent with the results of quality control samples analyzed during routine use. This method is therefore precise and suitable both for therapeutic drug monitoring and pharmacokinetic studies in most clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.