33 resultados para romä


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Aims: Due to a p aucity of s uch data we aimed to a ssess the type and f requency o f extraintestinal manifestations ( EIM) in I BD p atients and to e valuate their chronologic behavior. Methods: A nalysis of d ata from t he Swiss Inflammatory Bowel Disease Cohort (SIBDCS) which c ollects data since 2 005 on a large sample o f IBD patients f rom hospitals and private practices across Switzerland. Results: A t total o f 1,143 patients were a nalyzed ( 572 (50%) female, mean age 42.1 ± 14.4 years), 629 with Crohn's disease (CD), 501 with ulcerative colitis (UC), and 13 with indeterminate colitis ( IC). Of t hese, 3 74 (32.7%) presented o ne to five E IM (65% w ith CD, 3 3% w ith UC, 2% w ith IC). O f those patients suffering from EIM, 4 1.7% p resented two, 1 2.4% t hree, 5 .3% four, and 3.2% f ive E IM d uring lifetime. T he initial EIM presented with the following frequencies: p eripheral a rthritis (PA) 6 3.4%, ankylosing spondylitis (AS) 8 .1%, primary sclerosing cholangitis (PSC) 6%, uveitis 5.7%, oral a phthosis 5.7%, erythema nodosum (EN) 5 %, other 3 .6%, pyoderma gangrenosum 1.8%, psoriasis 0.7%. In only 7.1% of cases, the EIM m anifested before IBD diagnosis was made (median time 28 months b efore IBD diagnosis, I QR 7 -60 months), in 9 2.9% EIM m anifested a fter e stablished IBD d iagnosis (median 72 months, IQR 9-147 months). Conclusions: EIM are a frequent problem in IBD patients. The vast m ajority of E IM m anifest a fter I BD d iagnosis has b een established. P eripheral a rthritis, a nkylosing spondylitis, a nd PSC represent the most frequent first manifestations of an EIM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Aims: The international E EsAI s tudy g roup is currently d eveloping the first activity index ( EEsAI) specific for E osinophilic Esophagitis (EoE). G oal: T o develop, e valuate and validate the EEsAI. Methods: T he development c omprises three p hases: 1. Selection of c andidate items ( completed); 2. Evaluation of t he activity index i n a first patient cohort (in progress, p atient recruitment completed); and 3. Validation in a s econd EoE patient cohort. F ocus group interviews with patients were used in p hase 1 to g enerate patient r eported outcomes (PRO) according to g uidelines o f regulatory authorities (FDA a nd EMA), whereas the section of biologic items was developed by Delphi rounds o f international E oE experts from E urope and North America. Results: T he EEsAI has a modular c omposition to a ssess the following components o f EoE activity: p atient r eported outcomes, e ndoscopic activity, histologic activity, laboratory activity, a nd quality of l ife (QoL). Definitions for a ll aspects o f endoscopic and histologic appearance were e stablished by consensus r ounds a mong E oE experts. S ymptom a ssessment tools were c reated that t ake into account d ifferent food consistencies as w ell as f ood avoidance and specific processing strategies. The EEsAI i s currently e valuated in a cohort of a dult EoE patients since M arch 2 011 (patient recruitment completed). Conclusions: The EEsAI standardizes outcome assessment in EoE t rials. T he collaboration with i nternational E oE e xperts a s well as f ollowing o f the guidelines f rom regulatory authorities will lead to its wide applicability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine whether motion preservation following oblique cervical corpectomy (OCC) for cervical spondylotic myelopathy (CSM) persists with serial follow-up. METHODS: We included 28 patients with preoperative and at least two serial follow-up neutral and dynamic cervical spine radiographs who underwent OCC for CSM. Patients with an ossified posterior longitudinal ligament (OPLL) were excluded. Changes in sagittal curvature, segmental and whole spine range of motion (ROM) were measured. Nathan's system graded anterior osteophyte formation. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. RESULTS: The majority (23 patients) had a single or 2-level corpectomy. The average duration of follow-up was 45 months. The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). 17% of patients with preoperative lordotic spines had a loss of lordosis at last follow-up, but with no clinical worsening. 77% of the whole spine ROM and 62% of segmental ROM was preserved at last follow-up. The whole spine and segmental ROM decreased by 11.2° and 10.9°, respectively (p ≤ 0.001). Patients with a greater range of segmental movement preoperatively had a statistically greater range of movement at follow-up. The analysis of serial radiographs indicated that the range of movement of the whole spine and the range of movement at the segmental spine levels significantly reduced during the follow-up period. Nathan's grade showed increase in osteophytosis in more than two-thirds of the patients (p ≤ 0.01). The whole spine range of movement at follow-up significantly correlated with Nathan's grade. CONCLUSIONS: Although the OCC preserves segmental and whole spine ROM, serial measurements show a progressive decrease in ROM albeit without clinical worsening. The reduction in this ROM is probably related to degenerative ossification of spinal ligaments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background a nd A ims: D iscriminating irritable bowelsyndrome (IBS) from inflammatory bowel disease (IBD) can bea clinical c hallenge as s ymptoms c an overlap. We a nd othershave recently shown that fecal c alprotectin ( FC) is moreaccurate for d iscriminating IBS f rom IBD compared to C -reactive p rotein ( CRP) and b lood leukocytes. We a imed toassess which b iomarkers are used by g astroenterologists intheir daily practice for discriminating IBS from IBD.Methods: A q uestionnaire was sent to all board certifiedgastroenterologists in Switzerland in July 2010.Results: Response rate was 57% (153/270). Mean physician'sage was 50±9years, mean duration o f gastroenterologicpractice 1 4±8years, 52% of them were working in p rivatepractice a nd 48% in h ospitals. T he following biomarkers weredetermined for discriminating IBS from IBD: CRP 100%, FC79%, hematogram (red blood cells and leukocytes) 70%, ironstatus ( ferritin, t ransferrin s aturation) 59%, e rythrocytesedimentation rate 2.7%, protein electrophoresis 0.7%, andalpha-1 antitrypsin clearance 0.7%. There was a trend for usingFC more often in p rivate practice t han in h ospital ( P = 0.08).Eighty-nine percent of gastroenterologists considered FC to besuperior to CRP for discriminating IBS from IBD, 8 7% thoughtthat patient's compliance for fecal sampling is high, and 51%judged the fee of USD 60 for a FC test as appropriate.Conclusions: F C is widely used in c linical practice t odiscriminate IBS from IBD. In accordance with the scientificevidence, the majority of gastroenterologists consider FC to bemore accurate than CRP for discriminating IBS from IBD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background a nd A ims: D ilation of stenosing EosinophilicEsophagitis (EoE) is considered a high-risk procedure asperforation rates o f up to 9% of patients h ave been reported.Goal: To systematically e valuate the dilation-associatedperforation risk in stenosing EoE.Methods: A systematic review of the literature was performedusing pubmed and Embase. Keywords used were "eosinophilicesophagitis", "dilation", "perforation", and "complications".Results: F rom 2002 to 2007 7 case s eries including 85patients r eported perforations i n 5 patients ( perforation r ate6%). The highest perforation rate was reported in a series of 36patients d ocumenting 3 perforations ( 9%). In 2 010 and 2011three large studies r eporting o n a total o f 404 patientsdocumented a perforation in 3 patients (0.74%). The perforationrate reported in small case series before 2010 was significantlyhigher compared to the r ates since 2 010 ( P <0.001). Theoverall p erforation frequency is 8 /489 patients (1.6%). Amedian of 3 endoscopic sessions with dilations were performedper patient, thereby leading to a perforation rate of 0.53% perendoscopy. Follow-up information on EoE p atients w ithperforation was available in 6 s tudies, all patients c ould bemanaged conservatively, dilation-associated mortality waszero.Conclusions: D ilation of stenosing EoE h as a m uch lowerperforation risk as r eported in e arlier c ase series. Theperforation rate per endoscopy (0.53%) is much lower than theone reported for d ilation of achalasia ( 2-4%). T aking intoaccount t he latest data, dilation of stenosing EoE c an beregarded as a safe procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The book presents the state of the art in machine learning algorithms (artificial neural networks of different architectures, support vector machines, etc.) as applied to the classification and mapping of spatially distributed environmental data. Basic geostatistical algorithms are presented as well. New trends in machine learning and their application to spatial data are given, and real case studies based on environmental and pollution data are carried out. The book provides a CD-ROM with the Machine Learning Office software, including sample sets of data, that will allow both students and researchers to put the concepts rapidly to practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Project No. 369 (''Comparative Evolution of PeriTethyan Rift Basins'') of the International Geological Correlation Program produced a new palaeotectonic-palaeo-geographic atlas of the western PeriTethyan domain. The atlas contains more than two hundred new maps and documents grouped in nine regional sets (Iberia, Polish Trough, Eastern European and Scythian Platforms, Moesian Platform, Levant, Arabian Platform,, Northern Africa, NE Africa-NW Arabia, Libya-Pelagian Shelf plus a set of reconstructions for the whole western Tethys. The area, considered in the atlas stretches. from west to east, from the eastern Atlantic shores to the Urals and, from north to south, from the Baltic shield to equatorial Africa; the time span covered extends from the Late. Carboniferous to the Present. The dataset, resulting from an extensive cooperation between industrial and academic sources, is accessible interactively on a CD-ROM (Stampfli et al., 2001a) and includes legend, timetable, short explanatory notes, full references and additional supporting data. This dataset provides information on the development of the Tethyan realm in space and time. In particular, the relation between the Variscan and Cimmerian cycles in the Mediterranean realm is illustrated by numerous palaeogeographic and palaeotectonic maps.