27 resultados para quantum open system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. Harsh environmental conditions experienced during development can reduce the performance of the same individuals in adulthood. However, the 'predictive adaptive response' hypothesis postulates that if individuals adapt their phenotype during development to the environments where they are likely to live in the future, individuals exposed to harsh conditions in early life perform better when encountering the same harsh conditions in adulthood compared to those never exposed to these conditions before. 2. Using the common vole (Microtus arvalis) as study organism, we tested how exposure to flea parasitism during the juvenile stage affects the physiology (haematocrit, resistance to oxidative stress, resting metabolism, spleen mass, and testosterone), morphology (body mass, testis mass) and motor performance (open field activity and swimming speed) of the same individuals when infested with fleas in adulthood. According to the 'predictive adaptive response' hypothesis, we predicted that voles parasitized at the adult stage would perform better if they had already been parasitized with fleas at the juvenile stage. 3. We found that voles exposed to fleas in adulthood had a higher metabolic rate if already exposed to fleas when juvenile, compared to voles free of fleas when juvenile and voles free of fleas in adulthood. Independently of juvenile parasitism, adult parasitism impaired adult haematocrit and motor performances. Independently of adult parasitism, juvenile parasitism slowed down crawling speed in adult female voles. 4. Our results suggest that juvenile parasitism has long-term effects that do not protect from the detrimental effects of adult parasitism. On the contrary, experiencing parasitism in early-life incurs additional costs upon adult parasitism measured in terms of higher energy expenditure, rather than inducing an adaptive shift in the developmental trajectory. 5. Hence, our study provides experimental evidence for long term costs of parasitism. We found no support for a predictive adaptive response in this host-parasite system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cilengitide is a selective αvβ3 and αvβ5 integrin inhibitor. Data from phase 2 trials suggest that it has antitumour activity as a single agent in recurrent glioblastoma and in combination with standard temozolomide chemoradiotherapy in newly diagnosed glioblastoma (particularly in tumours with methylated MGMT promoter). We aimed to assess cilengitide combined with temozolomide chemoradiotherapy in patients with newly diagnosed glioblastoma with methylated MGMT promoter. METHODS: In this multicentre, open-label, phase 3 study, we investigated the efficacy of cilengitide in patients from 146 study sites in 25 countries. Eligible patients (newly diagnosed, histologically proven supratentorial glioblastoma, methylated MGMT promoter, and age ≥18 years) were stratified for prognostic Radiation Therapy Oncology Group recursive partitioning analysis class and geographic region and centrally randomised in a 1:1 ratio with interactive voice response system to receive temozolomide chemoradiotherapy with cilengitide 2000 mg intravenously twice weekly (cilengitide group) or temozolomide chemoradiotherapy alone (control group). Patients and investigators were unmasked to treatment allocation. Maintenance temozolomide was given for up to six cycles, and cilengitide was given for up to 18 months or until disease progression or unacceptable toxic effects. The primary endpoint was overall survival. We analysed survival outcomes by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00689221. FINDINGS: Overall, 3471 patients were screened. Of these patients, 3060 had tumour MGMT status tested; 926 patients had a methylated MGMT promoter, and 545 were randomly assigned to the cilengitide (n=272) or control groups (n=273) between Oct 31, 2008, and May 12, 2011. Median overall survival was 26·3 months (95% CI 23·8-28·8) in the cilengitide group and 26·3 months (23·9-34·7) in the control group (hazard ratio 1·02, 95% CI 0·81-1·29, p=0·86). None of the predefined clinical subgroups showed a benefit from cilengitide. We noted no overall additional toxic effects with cilengitide treatment. The most commonly reported adverse events of grade 3 or worse in the safety population were lymphopenia (31 [12%] in the cilengitide group vs 26 [10%] in the control group), thrombocytopenia (28 [11%] vs 46 [18%]), neutropenia (19 [7%] vs 24 [9%]), leucopenia (18 [7%] vs 20 [8%]), and convulsion (14 [5%] vs 15 [6%]). INTERPRETATION: The addition of cilengitide to temozolomide chemoradiotherapy did not improve outcomes; cilengitide will not be further developed as an anticancer drug. Nevertheless, integrins remain a potential treatment target for glioblastoma. FUNDING: Merck KGaA, Darmstadt, Germany.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As in cancer biology, in wound healing there is a need for objective staging systems to decide for the best treatment and predictors of outcome. We developed in the diabetic (db/db) wound healing model, a staging system, the "wound watch," based on the quantification of angiogenesis and cell proliferation in open wounds. In chronic wounds, there is often a lack of cellular proliferation and angiogenesis that leads to impaired healing. The wound watch addresses this by quantifying the proliferative phase of wound healing in two dimensions (cellular division and angiogenesis). The results are plotted in a two-dimensional graph to monitor the course of healing and compare the response to different treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The goal of this study was to investigate whether increasing the dose of an angiotensin II receptor blocker (ARB) provides as much benefits as combining the ARB with an angiotensin-converting enzyme inhibitor (ACEI) in terms of blood pressure (BP) control and urinary albumin excretion (UAE) in hypertensive patients with a proteinuria.Methods We enrolled 20 hypertensive patients with proteinuric nephropathies and a reduced renal function in a randomized, 12-month, triple-crossover, prospective, open-label study to compare the effects of a regular dose of losartan (Los 100mg q.d., LOS100) vs. a high dose of losartan (Los 100mg b.i.d., LOS200) vs. losartan 100mg q.d. associated with lisinopril 20 mg q.d. (LOS100 + LIS20). Each treatment was given for 8 weeks with a 4-week initial run-in period and 2 weeks of washout between each treatment phases. 24 h UAE and ambulatory BP were measured during the running phase and at the end of each treatment period.Results Compared to pretreatment, 24 h SBP and DBP were reduced by 10/5 +/- 7/4 mmHg with LOS100 (P=0.023 vs. baseline) and, respectively, 13/6 +/- 12/5 mmHg with LOS200 (P=0.011) and 19/9 +/- 15/8 mmHg with LOS100+LIS20 (P < 0.01). UAE decreased significantly with LOS100 and to an even greater degree with LOS200 and LOS100+LIS20 (P < 0.01 vs. baseline for both and P=0.032, LOS100+LIS20 vs. LOS200). The combination had a greater impact in patients with a high baseline proteinuria as suggested by a nonparallel leftward shift of the relationship between the changes in UAE induced by the combination and those induced by LOS200. The high dose of losartan was better tolerated than the combination.Conclusion Increasing the dose of losartan from 100mg once daily to 100mg twice a day enables to obtain a greater decrease in BP and proteinuria and is better tolerated than combining the ARB with lisinopril, though the high dose appears to be slightly less effective than the combination in patients with a marked proteinuria. J Hypertens 29: 1228-1235 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF THE STUDY: Fracture of the tibial pilon is a rare injury and its treatment remains difficult. The aim of this study was to report the complications and long term results of internal fixation using a technique which respects soft tissues and in which little material was used. MATERIAL: From 1985 to 1990, 48 patients with 51 fractures of the tibial pilon were treated by open reduction and internal fixation. All patients were submitted to a clinical and radiological review. METHODS: Both the Rüedi/Allgöwer and the AO-classification were used and determined by standard X-rays. Surgical procedure was performed with a 2 or 3 1/3 tube AO-plates and the peroneus was always fixed if fractured. Intraoperative reconstruction was analyzed. Subjective and objective scoring were used according to Olerud and Molander and the ankle arthritis was scored according to the classification determined by the SOFCOT in 1992. RESULTS: A minimal follow-up of 1 year for all cases was obtained, based on our own files. Thirty-eight patients (40 fractures) were evaluated after an average period of 88 months (56 to 124 months). Five patients developed cutaneous infection, three developed deep infection and four developed superficial skin necrosis. One aseptic non-union necessitated reoperation after 14 months. Two ankles had joint fusion after 19 and 25 months respectively due to severe arthritis. In six cases infectious and non-infectious complications led to surgical revision. According to the Olerud and Molander score, 15 per cent of the results were excellent, 45 per cent were good, 30 per cent were fair and 10 per cent poor. DISCUSSION: Literature shows a wide range of results following this surgical procedure. This is due to the difference in the type of trauma, classification system used, material used for the internal fixation and method of evaluation. The classification system of Rüedi and Allgöwer is the most commonly used but has a rather subjective tendency, especially between type II and type III. Treatment is difficult, especially for comminutive fractures associated with soft tissue damage. In this case, open reduction and internal fixation could increase iatrogenic lesions. For this reason surgical procedure can be delayed for several days, little material is used and soft tissue manipulation is reduced to minimum. In other study reports, the use of external fixation with or without minimal internal fixation have produced less complications without improving long term results. CONCLUSION: Analysis and comparison of study reports are difficult because of the absence of consensus in classification system and evaluation methods. The AO-classification, apparently the most objective, will probably be more and more used in the future. Treatment must be adapted to the bony lesion and soft tissue damage. Open reduction and internal fixation must be reserved for a specific group of lesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

How to recognize, announce and analyze incidents in internal medicine units is a daily challenge that is taught to all hospital staff. It allows suggesting useful improvements for patients, as well as for the medical department and the institution. Here is presented the assessment made in the CHUV internal medicine department one year after the beginning of the institutional procedure which promotes an open process regarding communication and risk management. The department of internal medicine underlines the importance of feedback to the reporters, ensures the staff of regular follow-up concerning the measures being taken and offers to external reporters such as general practioners the possibility of using this reporting system too.

Relevância:

30.00% 30.00%

Publicador: