23 resultados para development need


Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Shared decision-making is not widely implemented in healthcare. We aimed to set a research agenda about promoting shared decision-making through continuing professional development. METHODS: Thirty-six participants met for two days. RESULTS: Participants suggested ways to improve an environmental scan that had inventoried 53 shared decision-making training programs from 14 countries. Their proposed research agenda included reaching an international consensus on shared decision-making competencies and creating a framework for accrediting continuing professional development initiatives in shared decision-making. CONCLUSIONS: Variability in shared decision-making training programs showcases the need for quality assurance frameworks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: In the present review, we will provide the scientific rationale for applying systems biology to the development of vaccines and particularly HIV vaccines, the predictive power of systems biology on the vaccine immunological profile, the correlation between systems biology and the immunological functional profiles of different candidate vaccines, and the value of systems biology in the selection process of identifying the best-in-class candidate vaccines and in the decision process to move into in-vivo evaluation in clinical trials. RECENT FINDINGS: Systems biology has been recently applied to the characterization of the protective yellow fever vaccine YF17D and of seasonal flu vaccines. This has been instrumental in the identification of the components of the immune response that need to be stimulated by the vaccine in order to generate protective immunity. It is worth noting that a systems biology approach is currently being performed to identify correlates of immune protection of the RV144 Thai vaccine, the only known vaccine that showed modest protection against HIV reacquisition. SUMMARY: Systems biology represents a novel and powerful approach to predict the vaccine immunological profile, to identify the protective components of the immune response, and to help in the selection process of the best-in-class vaccines to move into clinical development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the major hurdles of isolating stable, inducible or constitutive high-level producer cell lines is the time-consuming selection procedure. Given the variation in the expression levels of the same construct in individual clones, hundreds of clones must be isolated and tested to identify one or more with the desired characteristics. Various boundary elements (BEs), matrix attachment regions, and locus control regions (LCRs) were screened for their ability to augment the expression of heterologous genes in Chinese hamster ovary (CHO) cells. Of the chromatin elements assayed, the chicken lysozyme matrix-attachment region (MAR) was the only element to significantly increase stable reporter expression. We found that the use of the MAR increases the proportion of high-producing clones, thus reducing the number of clones that need to be screened. These benefits are observed both for constructs with MARs flanking the transgene expression cassette, as well as when constructs are co-transfected with the MAR on a separate plasmid. Moreover, the MAR was co-transfected with a multicomponent regulatable beta-galactosidase expression system in C2C12 cells and several clones exhibiting regulated expression were identified. Hence, MARs are useful in the development of stable cell lines for production or regulated expression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Over the years, somatic care has become increasingly specialized. Furthermore, a rising number of patients requiring somatic care also present with a psychiatric comorbidity. As a consequence, the time and resources needed to care for these patients can interfere with the course of somatic treatment and influence the patient-caregiver relationship. In the light of these observations, the Liaison Psychiatry Unit at the University Hospital in Lausanne (CHUV) has educated its nursing staff in order to strengthen its action within the general care hospital. What has been developed is a reflexive approach through supervision of somatic staff, in order to improve the efficiency of liaison psychiatry interventions with the caregivers in charge of patients. The kind of supervision we have developed is the result of a real partnership with somatic staff. Besides, in order to better understand the complexity of interactions between the two systems involved, the patient's and the caregivers', we use several theoretical references in an integrative manner. PSYCHOANALYTICAL REFERENCE: The psychoanalytical model allows us to better understand the dynamics between the supervisor and the supervised group in order to contain and give meaning to the affects arising in the supervision space. "Containing function" and "transitional phenomena" refer to the experience in which emotions can find a space where they can be taken in and processed in a secure and supportive manner. These concepts, along with that of the "psychic envelope", were initially developed to explain the psychological development of the baby in its early interactions with its mother or its surrogate. In the field of supervision, they allow us to be aware of these complex phenomena and the diverse qualities to which a supervisor needs to resort, such as attention, support and incentive, in order to offer a secure environment. SYSTEMIC REFERENCE: A new perspective of the patient's complexity is revealed by the group's dynamics. The supervisor's attention is mainly focused on the work of affects. However, these are often buried under a defensive shell, serving as a temporary protection, which prevents the caregiver from recognizing his or her own emotions, thereby enhancing the difficulties in the relationship with the patient. Whenever the work of putting emotions into words fail, we use "sculpting", a technique derived from the systemic model. Through the use of this type of analogical language, affects can emerge without constraint or feelings of danger. Through "playing" in that "transitional space", new exchanges appear between group members and allow new behaviors to be conceived. In practice, we ask the supervisee who is presenting a complex situation, to design a spatial representation of his or her understanding of the situation, through the display of characters significant to the situation: the patient, somatic staff members, relatives of the patient, etc. In silence, the supervisee shapes the characters into postures and arranges them in the room. Each sculpted character is identified, named, and positioned, with his or her gaze being set in a specific direction. Finally the sculptor shapes him or herself in his or her own role. When the sculpture is complete and after a few moments of fixation, we ask participants to express themselves about their experience. By means of this physical representation, participants to the sculpture discover perceptions and feelings that were unknown up to then. Hence from this analogical representation a reflection and hypotheses of understanding can arise and be developed within the group. CONCLUSION: Through the use of the concepts of "containing function" and "transitional space" we position ourselves in the scope of the encounter and the dialog. Through the use of the systemic technique of "sculpting" we promote the process of understanding, rather than that of explaining, which would place us in the position of experts. The experience of these encounters has shown us that what we need to focus on is indeed what happens in this transitional space in terms of dynamics and process. The encounter and the sharing of competencies both allow a new understanding of the situation at hand, which has, of course, to be verified in the reality of the patient-caregiver relationship. It is often a source of adjustment for interpersonal skills to recover its containing function in order to enable caregiver to better respond to the patient's needs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Several European HIV observational data bases have, over the last decade, accumulated a substantial number of resistance test results and developed large sample repositories, There is a need to link these efforts together, We here describe the development of such a novel tool that allows to bind these data bases together in a distributed fashion for which the control and data remains with the cohorts rather than classic data mergers.METHODS: As proof-of-concept we entered two basic queries into the tool: available resistance tests and available samples. We asked for patients still alive after 1998-01-01, and between 180 and 195 cm of height, and how many samples or resistance tests there would be available for these patients, The queries were uploaded with the tool to a central web server from which each participating cohort downloaded the queries with the tool and ran them against their database, The numbers gathered were then submitted back to the server and we could accumulate the number of available samples and resistance tests.RESULTS: We obtained the following results from the cohorts on available samples/resistance test: EuResist: not availableI11,194; EuroSIDA: 20,71611,992; ICONA: 3,751/500; Rega: 302/302; SHCS: 53,78311,485, In total, 78,552 samples and 15,473 resistance tests were available amongst these five cohorts. Once these data items have been identified, it is trivial to generate lists of relevant samples that would be usefuI for ultra deep sequencing in addition to the already available resistance tests, Saon the tool will include small analysis packages that allow each cohort to pull a report on their cohort profile and also survey emerging resistance trends in their own cohort,CONCLUSIONS: We plan on providing this tool to all cohorts within the Collaborative HIV and Anti-HIV Drug Resistance Network (CHAIN) and will provide the tool free of charge to others for any non-commercial use, The potential of this tool is to ease collaborations, that is, in projects requiring data to speed up identification of novel resistance mutations by increasing the number of observations across multiple cohorts instead of awaiting single cohorts or studies to reach the critical number needed to address such issues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atherosclerosis is a chronic cardiovascular disease that involves the thicken¬ing of the artery walls as well as the formation of plaques (lesions) causing the narrowing of the lumens, in vessels such as the aorta, the coronary and the carotid arteries. Magnetic resonance imaging (MRI) is a promising modality for the assessment of atherosclerosis, as it is a non-invasive and patient-friendly procedure that does not use ionizing radiation. MRI offers high soft tissue con¬trast already without the need of intravenous contrast media; while modifica¬tion of the MR pulse sequences allows for further adjustment of the contrast for specific diagnostic needs. As such, MRI can create angiographic images of the vessel lumens to assess stenoses at the late stage of the disease, as well as blood flow-suppressed images for the early investigation of the vessel wall and the characterization of the atherosclerotic plaques. However, despite the great technical progress that occurred over the past two decades, MRI is intrinsically a low sensitive technique and some limitations still exist in terms of accuracy and performance. A major challenge for coronary artery imaging is respiratory motion. State- of-the-art diaphragmatic navigators rely on an indirect measure of motion, per¬form a ID correction, and have long and unpredictable scan time. In response, self-navigation (SM) strategies have recently been introduced that offer 100% scan efficiency and increased ease of use. SN detects respiratory motion di¬rectly from the image data obtained at the level of the heart, and retrospectively corrects the same data before final image reconstruction. Thus, SN holds po-tential for multi-dimensional motion compensation. To this regard, this thesis presents novel SN methods that estimate 2D and 3D motion parameters from aliased sub-images that are obtained from the same raw data composing the final image. Combination of all corrected sub-images produces a final image with reduced motion artifacts for the visualization of the coronaries. The first study (section 2.2, 2D Self-Navigation with Compressed Sensing) consists of a method for 2D translational motion compensation. Here, the use of com- pressed sensing (CS) reconstruction is proposed and investigated to support motion detection by reducing aliasing artifacts. In healthy human subjects, CS demonstrated an improvement in motion detection accuracy with simula¬tions on in vivo data, while improved coronary artery visualization was demon¬strated on in vivo free-breathing acquisitions. However, the motion of the heart induced by respiration has been shown to occur in three dimensions and to be more complex than a simple translation. Therefore, the second study (section 2.3,3D Self-Navigation) consists of a method for 3D affine motion correction rather than 2D only. Here, different techniques were adopted to reduce background signal contribution in respiratory motion tracking, as this can be adversely affected by the static tissue that surrounds the heart. The proposed method demonstrated to improve conspicuity and vi¬sualization of coronary arteries in healthy and cardiovascular disease patient cohorts in comparison to a conventional ID SN method. In the third study (section 2.4, 3D Self-Navigation with Compressed Sensing), the same tracking methods were used to obtain sub-images sorted according to the respiratory position. Then, instead of motion correction, a compressed sensing reconstruction was performed on all sorted sub-image data. This process ex¬ploits the consistency of the sorted data to reduce aliasing artifacts such that the sub-image corresponding to the end-expiratory phase can directly be used to visualize the coronaries. In a healthy volunteer cohort, this strategy improved conspicuity and visualization of the coronary arteries when compared to a con¬ventional ID SN method. For the visualization of the vessel wall and atherosclerotic plaques, the state- of-the-art dual inversion recovery (DIR) technique is able to suppress the signal coming from flowing blood and provide positive wall-lumen contrast. How¬ever, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. In response and as a fourth study of this thesis (chapter 3, Vessel Wall MRI of the Carotid Arteries), a phase-sensitive DIR method has been implemented and tested in the carotid arteries of a healthy volunteer cohort. By exploiting the phase information of images acquired after DIR, the proposed phase-sensitive method enhances wall-lumen contrast while widens the window of opportunity for image acquisition. As a result, a 3-fold increase in volumetric coverage is obtained at no extra cost in scanning time, while image quality is improved. In conclusion, this thesis presented novel methods to address some of the main challenges for MRI of atherosclerosis: the suppression of motion and flow artifacts for improved visualization of vessel lumens, walls and plaques. Such methods showed to significantly improve image quality in human healthy sub¬jects, as well as scan efficiency and ease-of-use of MRI. Extensive validation is now warranted in patient populations to ascertain their diagnostic perfor¬mance. Eventually, these methods may bring the use of atherosclerosis MRI closer to the clinical practice. Résumé L'athérosclérose est une maladie cardiovasculaire chronique qui implique le épaississement de la paroi des artères, ainsi que la formation de plaques (lé¬sions) provoquant le rétrécissement des lumières, dans des vaisseaux tels que l'aorte, les coronaires et les artères carotides. L'imagerie par résonance magné¬tique (IRM) est une modalité prometteuse pour l'évaluation de l'athérosclérose, car il s'agit d'une procédure non-invasive et conviviale pour les patients, qui n'utilise pas des rayonnements ionisants. L'IRM offre un contraste des tissus mous très élevé sans avoir besoin de médias de contraste intraveineux, tan¬dis que la modification des séquences d'impulsions de RM permet en outre le réglage du contraste pour des besoins diagnostiques spécifiques. À ce titre, l'IRM peut créer des images angiographiques des lumières des vaisseaux pour évaluer les sténoses à la fin du stade de la maladie, ainsi que des images avec suppression du flux sanguin pour une première enquête des parois des vais¬seaux et une caractérisation des plaques d'athérosclérose. Cependant, malgré les grands progrès techniques qui ont eu lieu au cours des deux dernières dé¬cennies, l'IRM est une technique peu sensible et certaines limitations existent encore en termes de précision et de performance. Un des principaux défis pour l'imagerie de l'artère coronaire est le mou¬vement respiratoire. Les navigateurs diaphragmatiques de pointe comptent sur une mesure indirecte de mouvement, effectuent une correction 1D, et ont un temps d'acquisition long et imprévisible. En réponse, les stratégies d'auto- navigation (self-navigation: SN) ont été introduites récemment et offrent 100% d'efficacité d'acquisition et une meilleure facilité d'utilisation. Les SN détectent le mouvement respiratoire directement à partir des données brutes de l'image obtenue au niveau du coeur, et rétrospectivement corrigent ces mêmes données avant la reconstruction finale de l'image. Ainsi, les SN détiennent un poten¬tiel pour une compensation multidimensionnelle du mouvement. A cet égard, cette thèse présente de nouvelles méthodes SN qui estiment les paramètres de mouvement 2D et 3D à partir de sous-images qui sont obtenues à partir des mêmes données brutes qui composent l'image finale. La combinaison de toutes les sous-images corrigées produit une image finale pour la visualisation des coronaires ou les artefacts du mouvement sont réduits. La première étude (section 2.2,2D Self-Navigation with Compressed Sensing) traite d'une méthode pour une compensation 2D de mouvement de translation. Ici, on étudie l'utilisation de la reconstruction d'acquisition comprimée (compressed sensing: CS) pour soutenir la détection de mouvement en réduisant les artefacts de sous-échantillonnage. Chez des sujets humains sains, CS a démontré une amélioration de la précision de la détection de mouvement avec des simula¬tions sur des données in vivo, tandis que la visualisation de l'artère coronaire sur des acquisitions de respiration libre in vivo a aussi été améliorée. Pourtant, le mouvement du coeur induite par la respiration se produit en trois dimensions et il est plus complexe qu'un simple déplacement. Par conséquent, la deuxième étude (section 2.3, 3D Self-Navigation) traite d'une méthode de cor¬rection du mouvement 3D plutôt que 2D uniquement. Ici, différentes tech¬niques ont été adoptées pour réduire la contribution du signal du fond dans le suivi de mouvement respiratoire, qui peut être influencé négativement par le tissu statique qui entoure le coeur. La méthode proposée a démontré une amélioration, par rapport à la procédure classique SN de correction 1D, de la visualisation des artères coronaires dans le groupe de sujets sains et des pa¬tients avec maladies cardio-vasculaires. Dans la troisième étude (section 2.4,3D Self-Navigation with Compressed Sensing), les mêmes méthodes de suivi ont été utilisées pour obtenir des sous-images triées selon la position respiratoire. Au lieu de la correction du mouvement, une reconstruction de CS a été réalisée sur toutes les sous-images triées. Cette procédure exploite la cohérence des données pour réduire les artefacts de sous- échantillonnage de telle sorte que la sous-image correspondant à la phase de fin d'expiration peut directement être utilisée pour visualiser les coronaires. Dans un échantillon de volontaires en bonne santé, cette stratégie a amélioré la netteté et la visualisation des artères coronaires par rapport à une méthode classique SN ID. Pour la visualisation des parois des vaisseaux et de plaques d'athérosclérose, la technique de pointe avec double récupération d'inversion (DIR) est capa¬ble de supprimer le signal provenant du sang et de fournir un contraste posi¬tif entre la paroi et la lumière. Pourtant, il est difficile d'obtenir un contraste optimal car cela est soumis à la variabilité du rythme cardiaque. Par ailleurs, l'imagerie DIR est inefficace du point de vue du temps et les acquisitions "mul- tislice" peuvent conduire à des temps de scan prolongés. En réponse à ce prob¬lème et comme quatrième étude de cette thèse (chapitre 3, Vessel Wall MRI of the Carotid Arteries), une méthode de DIR phase-sensitive a été implémenté et testé

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to examine developmental trends in response inhibition during childhood and to control for possible developmental influence of other basic cognitive processes (such as working memory and processing speed). In addition, we explored the relationships between response inhibition, working memory, and processing speed, as they are thought to be integral to cognitive control. Therefore, we assessed these three cognitive abilities in 159 children aged from 5 to 12. Results showed an improvement in response inhibition ability from 5 to 10 years of age. This improvement remained significant after controlling for the influence of working memory and processing speed. Furthermore, the developmental relationships showed an early differentiation between response inhibition, working memory, and processing speed. Thus, these processes were independent and need to be treated as such in further studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To develop and test the Parental PELICAN Questionnaire, an instrument to retrospectively assess parental experiences and needs during their child's end-of-life care. BACKGROUND: To offer appropriate care for dying children, healthcare professionals need to understand the illness experience from the family perspective. A questionnaire specific to the end-of-life experiences and needs of parents losing a child is needed to evaluate the perceived quality of paediatric end-of-life care. DESIGN: This is an instrument development study applying mixed methods based on recommendations for questionnaire design and validation. METHOD: The Parental PELICAN Questionnaire was developed in four phases between August 2012-March 2014: phase 1: item generation; phase 2: validity testing; phase 3: translation; phase 4: pilot testing. Psychometric properties were assessed after applying the Parental PELICAN Questionnaire in a sample of 224 bereaved parents in April 2014. Validity testing covered the evidence based on tests of content, internal structure and relations to other variables. RESULTS: The Parental PELICAN Questionnaire consists of approximately 90 items in four slightly different versions accounting for particularities of the four diagnostic groups. The questionnaire's items were structured according to six quality domains described in the literature. Evidence of initial validity and reliability could be demonstrated with the involvement of healthcare professionals and bereaved parents. CONCLUSION: The Parental PELICAN Questionnaire holds promise as a measure to assess parental experiences and needs and is applicable to a broad range of paediatric specialties and settings. Future validation is needed to evaluate its suitability in different cultures.