85 resultados para Sampling normative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mediastinal lymph-node dissection was compared to systematic mediastinal lymph-node sampling in patients undergoing complete resection for non-small cell lung cancer with respect to morbidity, duration of chest tube drainage and hospitalization, survival, disease-free survival, and site of recurrence. METHODS: A consecutive series of one hundred patients with non-small-cell lung cancer, clinical stage T1-3 N0-1 after standardized staging, was divided into two groups of 50 patients each, according to the technique of intraoperative mediastinal lymph-node assessment (dissection versus sampling). Mediastinal lymph-node dissection consisted of removal of all lymphatic tissues within defined anatomic landmarks of stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side according to the classification of the American Thoracic Society. Systematic mediastinal lymph-node sampling consisted of harvesting of one or more representative lymph nodes from stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side. RESULTS: All patients had complete resection. A mean follow-up time of 89 months was achieved in 92 patients. The two groups of patients were comparable with respect to age, gender, performance status, tumor stage, histology, extent of lung resection, and follow-up time. No significant difference was found between both groups regarding the duration of chest tube drainage, hospitalization, and morbidity. However, dissection required a longer operation time than sampling (179 +/- 38 min versus 149 +/- 37 min, p < 0.001). There was no significant difference in overall survival between the two groups; however, patients with stage I disease had a significantly longer disease-free survival after dissection than after sampling (60.2 +/- 7 versus 44.8 +/- 8 months, p < 0.03). Local recurrence was significantly higher after sampling than after dissection in patients with stage I tumor (12.5% versus 45%, p = 0.02) and in patients with nodal tumor negative mediastinum (N0/N1 disease) (46% versus 13%, p = 0.004). CONCLUSION: Our results suggest that mediastinal lymph-node dissection may provide a longer disease-free survival in stage I non-small cell lung cancer and, most importantly, a better local tumor control than mediastinal lymph-node sampling after complete resection for N0/N1 disease without leading to increased morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6 mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4 g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm® M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cette étude normative de l'épreuve de Rorschach porte sur une population suisse de 102 enfants et adolescents non-consultants de 8 à 14 ans, répartis par tranches d'âge, sexe et niveau intellectuel. Elle présente un aperçu des différentes méthodes utilisées dans l'interprétation du Rorschach et des normes francophones existantes. Une réflexion est aussi proposée autour de la question de l'utilité de l'analyse des facteurs quantitatifs au Rorschach. Suite à une présentation détaillée de la méthodologie de recherche, les résultats sont exposés et comparés aux normes antérieures. Ils ne révèlent pas de différences importantes avec ces dernières, à l'exception de la hausse du F%, de la baisse du F+% et du nombre de Banalités. Les comparaisons Age, Sexe et QI révèlent quelques différences entre les groupes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The neo-liberal capitalist ideology has come under heavy fire with anecdotal evidence indicating a link between these same values and unethical behavior. Academic institutions reflect social values and act as socializing agents for the young. Can this explain the high and increasing rates of cheating that currently prevail in education? Our first chapter examines the question of whether self-enhancement values of power and açhievement, the individual level equivalent of neo-liberal capitalist values, predict positive attitudes towards cheating. Furthermore, we explore the mediating role of motivational factors. Results of four studies reveal that self-enhancement value endorsement predicts the adoption of performance-approach goals, a relationship mediated by introjected regulation, namely desire for social approval and that self-enhancement value endorsement also predicts the condoning of cheating, a relationship mediated by performance-approach goal adoption. However, self-transcendence values prescribed by a normatively salient source have the potential to reduce the link between self-enhancement value endorsément and attitudes towards cheating. Normative assessment constitutes a key tool used by academic institutions to socialize young people to accept the competitive, meritocratic nature of a sociéty driven by a neo-liberal capitalist ideology. As such, the manifest function of grades is to motivate students to work hard and to buy into the competing ethos. Does normative assessment fulfill these functions? Our second chapter explores the reward-intrinsic motivation question in the context of grading, arguably a high-stakes reward. In two experiments, the relative capacity of graded high performance as compared to the task autonomy experienced in an ungraded task to predict post-task intrinsic motivation is assessed. Results show that whilst the graded task performance predicts post-task appreciation, it fails to predict ongoing motivation. However, perceived autonomy experienced in non-graded condition, predicts both post-task appreciation and ongoing motivation. Our third chapter asks whether normative assessment inspires the spirit of competition in students. Results of three experimental studies reveal that expectation of a grade for a task, compared to no grade, induces greater adoption of performance-avoidance, but not performance-approach, goals. Experiment 3 provides an explanatory mechanism for this, showing that reduced autonomous motivation experienced in previous graded tasks mediates the relationship between grading and adoption of performance avoidance goals in a subsequent task. The above results, when combined, provide evidence as to the deleterious effects of self enhancement values and the associated practice of normative assessment in school on student motivation, goals and ethics. We conclude by using value and motivation theory to explore solutions to this problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.