363 resultados para QUADRUPOLE DOUBLE-RESONANCE
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.
Resumo:
BACKGROUND Chromated glycerin (CG) is an effective, although painful, sclerosing agent for telangiectasias and reticular leg veins treatment. OBJECTIVE To determine pain level and relative efficacy of pure or one-third lidocaine-epinephrine 1% mixed chromated glycerin in a prospective randomized double-blind trial. METHOD Patients presenting with telangiectasias and reticular leg veins on the lateral aspect of the thigh (C(1A) or (S) E(P) A(S) P(N1) ) were randomized to receive pure CG or CG mixed with one-third lidocaine-epinephrine 1% (CGX) treatment. Lower limb photographs were taken before and after treatment and analyzed by blinded expert reviewers for efficacy assessment (visual vein disappearance). Patients' pain and satisfaction were assessed using visual analogue scales. RESULTS Data from 102 of 110 randomized patients could be evaluated. Patient pain scores were significantly higher when pure CG was used than with CGX (p<.001). Patient satisfaction with treatment outcome was similar in the two groups. Objective visual assessment of vessel disappearance revealed no significant difference between the two agents (p=.07). CONCLUSION Addition of lidocaine-epinephrine 1% to CG, in a ratio of one-third, significantly reduces sclerotherapy pain without affecting efficacy when treating telangiectasias and reticular leg veins. The authors have indicated no significant interest with commercial supporters.
Resumo:
Recent studies have demonstrated the immunomodulatory properties of vitamin D, and vitamin D deficiency may be a risk factor for the development of MS. The risk of developing MS has, in fact, been associated with rising latitudes, past exposure to sun and serum vitamin D status. Serum 25-hydroxyvitamin D [25(OH)D] levels have also been associated with relapses and disability progression. The identification of risk factors, such as vitamin D deficiency, in MS may provide an opportunity to improve current treatment strategies, through combination therapy with established MS treatments. Accordingly, vitamin D may play a role in MS therapy. Small clinical studies of vitamin D supplementation in patients with MS have reported positive immunomodulatory effects, reduced relapse rates and a reduction in the number of gadolinium-enhancing lesions. However, large randomized clinical trials of vitamin D supplementation in patients with MS are lacking. SOLAR (Supplementation of VigantOL(®) oil versus placebo as Add-on in patients with relapsing-remitting multiple sclerosis receiving Rebif(®) treatment) is a 96-week, three-arm, multicenter, double-blind, randomized, placebo-controlled, Phase II trial (NCT01285401). SOLAR will evaluate the efficacy of vitamin D(3) as add-on therapy to subcutaneous interferon beta-1a in patients with RRMS. Recruitment began in February 2011 and is aimed to take place over 1 calendar year due to the potential influence of seasonal differences in 25(OH)D levels.
Resumo:
During upper blepharoplasty, myocutaneous excess and fat pads are treated using an anterior approach. Eyelid malpositions such as involutional ptosis or lid retraction could be associated and should be treated with associated procedures. Aponeurotic surgery on the levator muscle can make use of the same anterior approach, with the major difficulty of dosage. In cases of ptosis with a positive epinephrine test or minor muscular retraction, the Muller muscle-conjunctival surgery via a posterior approach seems to be more reproducible. Double-approach techniques are described.
Resumo:
Coronary magnetic resonance angiography (MRA) is a technique aimed at establishing a noninvasive test for the assessment of significant coronary stenoses. There are certain boundary conditions that have hampered the clinical success of coronary MRA and coronary vessel wall imaging. Recent advances in hardware and software allow for consistent visualization of the proximal and mid portions of the native coronary arteries. Current research focuses on the use of intravascular MR contrast agents and black blood coronary angiography. One common goal is to create a noninvasive test which might allow for screening for major proximal and mid coronary artery disease. These novel approaches will represent a major step forward in diagnostic cardiology.
Resumo:
RATIONALE: This study assessed the efficacy and safety of canakinumab, a fully human anti-interleukin-1beta monoclonal antibody, for prophylaxis against acute gouty arthritis flares in patients initiating uratelowering therapy.METHODS: In this double-blind, double-dummy, dose-ranging study, 432 patients with gouty arthritis initiating allopurinol therapy were randomised 1:1:1:1:1:1:2 to receive: a single dose of canakinumab, 25, 50, 100, 200, or 300 mg subcutaneously (sc); four 4-weekly doses of canakinumab (50150125125 mg sc); or daily colchicine 0.5 mg orally for 16 weeks. Patients recorded details of flares in diaries. The study aimed to determine the canakinumab dose having equivalent efficacy to colchicine 0.5 mg at 16 weeks.RESULTS: A dose-response for canakinumab was not apparent with any of the four pre-defined dose-responsemodels. The estimated canakinumab dose with equivalent efficacy to colchicinewas belowthe range of doses tested.At 16 weeks, therewas a 62-72% reduction in themean number of flares per patient for canakinumab doses >50 mg vs colchicine based on a negative binomial model (rate ratio: 0.28-0.38, p50.0083), and the percentage of patients experiencing >1 flarewas significantly lower for all canakinumab doses (15- 27%) vs colchicine (44%, p<0.05). Therewas a 64-72%reduction in the risk of experiencing >1 flare for canakinumab doses >50 mg vs colchicine at 16 weeks (hazard ratio: 0.28-0.36, p50.05). The incidence of adverse events was similar across treatment groups.CONCLUSIONS: Single canakinumab doses >50 mg or four 4-weekly doses provided superior prophylaxis against flares compared with daily colchicine 0.5 mg.
Resumo:
BACKGROUND: According to recent guidelines, patients with coronary artery disease (CAD) should undergo revascularization if significant myocardial ischemia is present. Both, cardiovascular magnetic resonance (CMR) and fractional flow reserve (FFR) allow for a reliable ischemia assessment and in combination with anatomical information provided by invasive coronary angiography (CXA), such a work-up sets the basis for a decision to revascularize or not. The cost-effectiveness ratio of these two strategies is compared. METHODS: Strategy 1) CMR to assess ischemia followed by CXA in ischemia-positive patients (CMR + CXA), Strategy 2) CXA followed by FFR in angiographically positive stenoses (CXA + FFR). The costs, evaluated from the third party payer perspective in Switzerland, Germany, the United Kingdom (UK), and the United States (US), included public prices of the different outpatient procedures and costs induced by procedural complications and by diagnostic errors. The effectiveness criterion was the correct identification of hemodynamically significant coronary lesion(s) (= significant CAD) complemented by full anatomical information. Test performances were derived from the published literature. Cost-effectiveness ratios for both strategies were compared for hypothetical cohorts with different pretest likelihood of significant CAD. RESULTS: CMR + CXA and CXA + FFR were equally cost-effective at a pretest likelihood of CAD of 62% in Switzerland, 65% in Germany, 83% in the UK, and 82% in the US with costs of CHF 5'794, euro 1'517, £ 2'680, and $ 2'179 per patient correctly diagnosed. Below these thresholds, CMR + CXA showed lower costs per patient correctly diagnosed than CXA + FFR. CONCLUSIONS: The CMR + CXA strategy is more cost-effective than CXA + FFR below a CAD prevalence of 62%, 65%, 83%, and 82% for the Swiss, the German, the UK, and the US health care systems, respectively. These findings may help to optimize resource utilization in the diagnosis of CAD.