53 resultados para Method Development


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several methods are available for coding body movement in nonverbal behavior research, but there is no consensus on a reliable coding system that can be used for the study of emotion expression. Adopting an integrative approach, we developed a new method, the Body Action and Posture (BAP) coding system, for the time-aligned micro description of body movement on an anatomical level (different articulations of body parts), a form level (direction and orientation of movement), and a functional level (communicative and self-regulatory functions). We applied the system to a new corpus of acted emotion portrayals, examined its comprehensiveness and demonstrated intercoder reliability at three levels: a) occurrence, b) temporal precision and c) segmentation. We discuss issues for further validation and propose some research applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians, and health services researchers. Methods: Recommendations were developed using the standardised RAND appropriateness method. A literature search was performed for the period between 1995 and 2008 based on terms associated with guidelines and with respiratory care. Publications were assessed according to the Oxford classification of quality of evidence. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. Each indication for respiratory care was classified as appropriate, uncertain, or inappropriate, based on the panel median rating and the degree of intra-panel agreement. Results: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning, noninstrumental airway clearance techniques. Each recommendation referred to a particular medical condition, and was assigned to a hierarchical category based on the quality of evidence from literature supporting the recommendation and on the consensus of experts. Conclusion: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R (2) = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[Table des matières] 1. Introduction to the control banding method : Nanomaterials and occupational risk assessment; Alternative method known as control banding; Scope and limits of control banding. - 2. Control banding process applied to manufactured nanomaterials: General points; Operating principle. - 3. Implementation of control banding: Gathering of information; Hazard bands; Exposure bands; Allocation of risk control bands. - 4. Bibliography: Publications; Books, reports, opinions, bulletins; Standards and references; Legislation and regulations; Websites. - Annexes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Spine surgery rates are increasing worldwide. Treatment failures are often attributed to poor patient selection and inappropriate treatment, but for many spinal disorders there is little consensus on the precise indications for surgery. With an aging population, more patients with lumbar degenerative spondylolisthesis (LDS) will present for surgery. The aim of this study was to develop criteria for the appropriateness of surgery in symptomatic LDS. METHODS: A systematic review was carried out to summarize the current level of evidence for the treatment of LDS. Clinical scenarios were generated comprising combinations of signs and symptoms in LDS and other relevant variables. Based on the systematic review and their own clinical experience, twelve multidisciplinary international experts rated each scenario on a 9-point scale (1 highly inappropriate, 9 highly appropriate) with respect to performing decompression only, fusion, and instrumented fusion. Surgery for each theoretical scenario was classified as appropriate, inappropriate, or uncertain based on the median ratings and disagreement in the ratings. RESULTS: 744 hypothetical scenarios were generated; overall, surgery (of some type) was rated appropriate in 27 %, uncertain in 41 % and inappropriate in 31 %. Frank panel disagreement was low (7 % scenarios). Face validity was shown by the logical relationship between each variable's subcategories and the appropriateness ratings, e.g., no/mild disability had a mean appropriateness rating of 2.3 ± 1.5, whereas the rating for moderate disability was 5.0 ± 1.6 and for severe disability, 6.6 ± 1.6. Similarly, the average rating for no/minimal neurological abnormality was 2.3 ± 1.5, increasing to 4.3 ± 2.4 for moderate and 5.9 ± 1.7 for severe abnormality. The three variables most likely (p < 0.0001) to be components of scenarios rated "appropriate" were: severe disability, no yellow flags, and severe neurological deficit. CONCLUSION: This is the first study to report criteria for determining candidacy for surgery in LDS developed by a multidisciplinary international panel using a validated method (RAM). The panel ratings followed logical clinical rationale, indicating good face validity. The work refines clinical classification and the phenotype of degenerative spondylolisthesis. The predictive validity of the criteria should be evaluated prospectively to examine whether patients treated "appropriately" have better clinical outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The NALP3 inflammasome functions as a sensor of danger signals and triggers processing and release of IL-1b. Mutations of NALP3 are responsible for the cryopyrin associated periodic syndromes, a group of autoinflammatory disorders that respond to IL1 inhibition. Genetic studies have also linked NALP3 to hypertension in man, but the mechanism is not understood. The aim of this study is to investigate the role of NAPL3 inflammasome in the development of hypertension in an animal model. Design and Method: Six-week old male WT and NALP3 KO mice were used for generating a two-kidney, one clip (2K1C) renovascular hypertension. A U-shaped stainless steel clip (O^ ¼0.12mm) was placed on left renal artery under anaesthesia. The same surgery without clipping was performed in sham mice. At week 6 and 12 after the clipping, intra-arterial blood pressure (BP) was measured in conscious mice. Blood was collected for plasma renin analysis. Heart and kidney were excised and stored for molecular and morphological examinations. n¼5-6 mice per group. Data are mean_SEM. Results: Mean BP was significantly increased at week 6 and 12 in WT-2K1C mice compared to WT-sham group (MBPweek6: 138_2 vs.124_3 mmHg, p<0.01 and MBPweek12: 141_5 vs.122_3 mmHg, p<0.01) followed with an significant increase in heart weight (HW) and a decrease in clipped kidney weight indices in WT-2K1C mice compared to the WT-sham (HW/ BWweek6: 4.65_0.04 vs. 3.99_0.12 mg/g, p<0.001 and HW/BWweek12: 4.94_0.15 vs. 4.22_0.12 mg/g, p<0.001). Interestingly, NALP3 KO-2K1C mice did not develop hypertension. The MBP of KO-2K1C mice was comparable to the KO-sham (MBPweek6: 122_3 vs. 119_3 mmHg, p>0.05 and MBPweek6: 128_5 vs.122_4 mmHg, p>0.05). There was also no significant change in heart and kidney weight indices between KO- 2K1C and KO-sham mice. Conclusion: The preliminary results suggest that absence of NALP3 protects mice from the development of renin-dependent hypertension. Further molecular and morphological examinations are ongoing for the confirmation and mechanism explanation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study objectives: Many major drugs are not available in paediatric form. The aim of this study was to develop a stable liquid solution of captopril for oral paediatric use allowing individualised dosage and easy administration to newborn and young patients. Methods: A specific HPLC-UV method was developed. In a pilot study, a number of formulations described in the literature as affording one-month stability were examined. In the proper long-term study, the formulation that gave the best results was then prepared in large batches and its stability monitored for two years at 5°C and room temperature, and for one year at 40°C. Results: Most formulations described in the literature were found wanting in our pilot study. A simple solution of the drug (1 mg/mL) in purified water (European Pharmacopeia) containing 0.1% disodium edetate (EDTA-Na) as preservative proved chemically and microbiologically stable at 5°C and room temperature for two years. Conclusion: The proposed in-house formulation fulfils stringent criteria of purity and stability and is fully acceptable for oral administration to newborn and young patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To measure postabsorptive fat oxidation (F(ox)) and to assess its association with body composition (lean body mass [LBM] and body fat mass [BFM]) and pubertal development. DESIGN: We studied 235 control (male/female ratio = 116/119; age [mean +/- SD]: 13.1 +/- 1.7 years; weight: 45.3 +/- 10.5 kg; LBM: 34.3 +/- 7.1 kg; BFM: 11.0 +/- 4.5 kg) and 159 obese (male/female ratio = 93/66; age: 12.9 +/- 2.1 years; weight: 76.2 +/- 19.1 kg; LBM: 47.4 +/- 10.9 kg; BFM: 28.8 +/- 9.2 kg) adolescents. Postabsorptive F(ox) was calculated from oxygen consumption, carbon dioxide production, and urinary nitrogen as measured by indirect calorimetry and Kjeldahl's method, respectively. Body composition was determined by anthropometry. RESULTS: Postabsorptive F(ox) (absolute value and percentage of resting metabolic rate) was significantly (p < 0.001) higher in the obese adolescents (76.7 +/- 26.3 gm/24 hours, 42.3% +/- 18.7%) than in the control subjects (40.0 +/- 26.3 gm/24 hours, 28.7% +/- 17.0%), even if adjusted for LBM. F(ox) corrected for BFM was similar in control and in obese children, but was significantly lower in girls compared with boys (control male subjects: 62.1 +/- 29.1 gm/24 hours, control female subjects: 51.6 +/- 28.4 gm/24 hours, obese male subjects: 57.3 +/- 29 gm/24 hour, obese female subjects: 45.0 +/- 28.4 gm/24 hours). BFM and LBM showed a significant positive correlation with F(ox). By stepwise regression analysis the most important determinant of F(ox) was BFM in obese and LBM in control children. There was a significant rise in F(ox) during puberty; however, it was mainly explained by changes in body composition. CONCLUSIONS: Obese adolescents have higher F(ox) rates than their normal-weight counterparts. Both LBM and fat mass are important determinants of F(ox).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hand development in the European shrew Crocidura russula is described, based on the examination of a cleared and double-stained ontogenetic series and histological sections of a c. 20-day-old embryo and a neonate. In the embryo all carpal elements are still mesenchymal condensations, and there are three more elements than in the adult stage: the 'lunatum', which fuses with the scaphoid around birth; a centrale, which either fuses with another carpal element or just disappears later in ontogeny; and the anlage of an element that later fuses with the radius. Carpal arrangement in the neonate and the adult is the same. In order to compare the relative timing of the onset of ossification in forelimb bones in C. russula with that of other therians, we built up two matrices of events based on two sets of data and used the event-pair method. In the first analysis, ossification of forelimb elements in general was examined, including that of the humerus, radius, ulna, the first carpal and metacarpal to ossify, and the phalanges of the third digit. The second analysis included each carpal, humerus, radius, ulna, the first metacarpal and the first phalanx to ossify. Some characters (= event-pairs) provide synapomorphies for some clades examined. There have been some shifts in the timing of ossification apparently not caused by ecological and/or environmental influences. In two species (Oryctolagus and Myotis), there is a tendency to start the ossification of the carpals relatively earlier than in all other species examined, the sauropsid outgroups included.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Q fever is a worldwide zoonotic infectious disease due to Coxiella burnetii. The clinical presentation may be acute (pneumonia and/or hepatitis) or chronic (most commonly endocarditis). Diagnosis mainly relies on serology and PCR. We therefore developed a quantitative real-time PCR. We first tested blindly its performance on various clinical samples and then, when thoroughly validated, we applied it during a 7-year period for the diagnosis of both acute and persistent C. burnetii infection. Analytical sensitivity (< 10 copies/PCR) was excellent. When tested blindly on 183 samples, the specificity of the PCR was 100% (142/142) and the sensitivity was 71% (29/41). The sensitivity was 88% (7/8) on valvular samples, 69% (20/29) on blood samples and 50% (2/4) on urine samples. This new quantitative PCR was then successfully applied for the diagnosis of acute Q fever and endovascular infection due to C. burnetii, allowing the diagnosis of Q fever in six patients over a 7-year period. During a local small cluster of cases, the PCR was also applied to blood from 1355 blood donors; all were negative confirming the high specificity of this test. In conclusion, we developed a highly specific method with excellent sensitivity, which may be used on sera for the diagnosis of acute Q fever and on various samples such as sera, valvular samples, aortic specimens, bone and liver, for the diagnosis of persistent C. burnetii infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed a method of sample preparation using epoxy compound, which was validated in two steps. First, we studied the homogeneity within samples by scanning tubes filled with radioactive epoxy. We found within-sample homogeneity better than 2%. Then, we studied the homogeneity between samples during a 4.5 h dispensing time. The homogeneity between samples was found to be better than 2%. This study demonstrates that we have a validated method, which assures the traceability of epoxy samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated microcalorimetry for real-time susceptibility testing of Aspergillus spp. based on growth-related heat production. The minimal heat inhibitory concentration (MHIC) for A. fumigatus ATCC 204305 was 1 mg/L for amphotericin B, 0.25 mg/L for voriconazole, 0.06 mg/L for posaconazole, 0.125 mg/L for caspofungin and 0.03 mg/L for anidulafungin. Agreement within two 2-fold dilutions between MHIC (determined by microcalorimetry) and MIC or MEC (determined by CLSI M38A) was 90% for amphotericin B, 100% for voriconazole, 90% for posaconazole and 70% for caspofungin. This proof-of-concept study demonstrated the potential of isothermal microcalorimetry for growth evaluation of Aspergillus spp. and real-time antifungal susceptibility testing.