67 resultados para In-plane bending
Resumo:
With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.
Resumo:
Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.
Resumo:
During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.
Resumo:
PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.
Resumo:
Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.
Resumo:
The purpose of this study was to investigate the impact of in-plane coronary artery motion on coronary magnetic resonance angiography (MRA) and coronary MR vessel wall imaging. Free-breathing, navigator-gated, 3D-segmented k-space turbo field echo ((TFE)/echo-planar imaging (EPI)) coronary MRA and 2D fast spin-echo coronary vessel wall imaging of the right coronary artery (RCA) were performed in 15 healthy adult subjects. Images were acquired at two different diastolic time periods in each subject: 1) during a subject-specific diastasis period (in-plane velocity <4 cm/second) identified from analysis of in-plane coronary artery motion, and 2) using a diastolic trigger delay based on a previously implemented heart-rate-dependent empirical formula. RCA vessel wall imaging was only feasible with subject-specific middiastolic acquisition, while the coronary wall could not be identified with the heart-rate-dependent formula. For coronary MRA, RCA border definition was improved by 13% (P < 0.001) with the use of subject-specific trigger delay (vs. heart-rate-dependent delay). Subject-specific middiastolic image acquisition improves 3D TFE/EPI coronary MRA, and is critical for RCA vessel wall imaging.
Resumo:
In vivo fetal magnetic resonance imaging provides aunique approach for the study of early human braindevelopment [1]. In utero cerebral morphometry couldpotentially be used as a marker of the cerebralmaturation and help to distinguish between normal andabnormal development in ambiguous situations. However,this quantitative approach is a major challenge becauseof the movement of the fetus inside the amniotic cavity,the poor spatial resolution provided by very fast MRIsequences and the partial volume effect. Extensiveefforts are made to deal with the reconstruction ofhigh-resolution 3D fetal volumes based on severalacquisitions with lower resolution [2,3,4]. Frameworkswere developed for the segmentation of specific regionsof the fetal brain such as posterior fossa, brainstem orgerminal matrix [5,6], or for the entire brain tissue[7,8], applying the Expectation-Maximization MarkovRandom Field (EM-MRF) framework. However, many of theseprevious works focused on the young fetus (i.e. before 24weeks) and use anatomical atlas priors to segment thedifferent tissue or regions. As most of the gyraldevelopment takes place after the 24th week, acomprehensive and clinically meaningful study of thefetal brain should not dismiss the third trimester ofgestation. To cope with the rapidly changing appearanceof the developing brain, some authors proposed a dynamicatlas [8]. To our opinion, this approach however faces arisk of circularity: each brain will be analyzed /deformed using the template of its biological age,potentially biasing the effective developmental delay.Here, we expand our previous work [9] to proposepost-processing pipeline without prior that allow acomprehensive set of morphometric measurement devoted toclinical application. Data set & Methods: Prenatal MRimaging was performed with a 1-T system (GE MedicalSystems, Milwaukee) using single shot fast spin echo(ssFSE) sequences (TR 7000 ms, TE 180 ms, FOV 40 x 40 cm,slice thickness 5.4mm, in plane spatial resolution1.09mm). For each fetus, 6 axial volumes shifted by 1 mmwere acquired under motherâeuro?s sedation (about 1min pervolume). First, each volume is segmentedsemi-automatically using region-growing algorithms toextract fetal brain from surrounding maternal tissues.Inhomogeneity intensity correction [10] and linearintensity normalization are then performed. Brain tissues(CSF, GM and WM) are then segmented based on thelow-resolution volumes as presented in [9]. Ahigh-resolution image with isotropic voxel size of 1.09mm is created as proposed in [2] and using B-splines forthe scattered data interpolation [11]. Basal gangliasegmentation is performed using a levet setimplementation on the high-resolution volume [12]. Theresulting white matter image is then binarized and givenas an input in FreeSurfer software(http://surfer.nmr.mgh.harvard.edu) to providetopologically accurate three-dimensional reconstructionsof the fetal brain according to the local intensitygradient. References: [1] Guibaud, Prenatal Diagnosis29(4) (2009). [2] Rousseau, Acad. Rad. 13(9), 2006. [3]Jiang, IEEE TMI 2007. [4] Warfield IADB, MICCAI 2009. [5]Claude, IEEE Trans. Bio. Eng. 51(4) 2004. [6] Habas,MICCAI 2008. [7] Bertelsen, ISMRM 2009. [8] Habas,Neuroimage 53(2) 2010. [9] Bach Cuadra, IADB, MICCAI2009. [10] Styner, IEEE TMI 19(39 (2000). [11] Lee, IEEETrans. Visual. And Comp. Graph. 3(3), 1997. [12] BachCuadra, ISMRM 2010.
Resumo:
Phototropic hypocotyl bending in response to blue light excitation is an important adaptive process that helps plants to optimize their exposure to light. In Arabidopsis thaliana, phototropic hypocotyl bending is initiated by the blue light receptors and protein kinases phototropin1 (phot1) and phot2. Phototropic responses also require auxin transport and were shown to be partially compromised in mutants of the PIN-FORMED (PIN) auxin efflux facilitators. We previously described the D6 PROTEIN KINASE (D6PK) subfamily of AGCVIII kinases, which we proposed to directly regulate PIN-mediated auxin transport. Here, we show that phototropic hypocotyl bending is strongly dependent on the activity of D6PKs and the PIN proteins PIN3, PIN4, and PIN7. While early blue light and phot-dependent signaling events are not affected by the loss of D6PKs, we detect a gradual loss of PIN3 phosphorylation in d6pk mutants of increasing complexity that is most severe in the d6pk d6pkl1 d6pkl2 d6pkl3 quadruple mutant. This is accompanied by a reduction of basipetal auxin transport in the hypocotyls of d6pk as well as in pin mutants. Based on our data, we propose that D6PK-dependent PIN regulation promotes auxin transport and that auxin transport in the hypocotyl is a prerequisite for phot1-dependent hypocotyl bending.
Resumo:
Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.
Resumo:
Introduction : Le bloc transverse de l'abdomen (bloc TAP, Transversus Abdominis Plane) échoguidé consiste en l'injection d'anesthésique local dans la paroi abdominale entre les muscles oblique interne et transverse de l'abdomen sous contrôle échographique. Ceci permet de bloquer l'innervation sensitive de la paroi antérolatérale de l'abdomen afin de soulager la douleur après des interventions chirurgicales. Auparavant, cette procédure reposait sur une technique dite « à l'aveugle » qui utilisait des repères anatomiques de surface. Depuis quelques années, cette technique est effectuée sous guidage échographique ; ainsi, il est possible de visualiser les structures anatomiques, l'aiguille et l'anesthésique local permettant ainsi une injection précise de l'anesthésique local à l'endroit désiré. Les précédentes méta- analyses sur le bloc TAP n'ont inclus qu'un nombre limité d'articles et n'ont pas examiné l'effet analgésique spécifique de la technique échoguidée. L'objectif de cette méta-analyse est donc de définir l'efficacité analgésique propre du bloc TAP échoguidé après des interventions abdominales chez une population adulte. Méthode : Cette méta-analyse a été effectuée selon les recommandations PRISMA. Une recherche a été effectuée dans les bases de donnée MEDLINE, Cochrane Central Register of Controlled Clinical Trials, Excerpta Medica database (EMBASE) et Cumulative Index to Nursing and Allied Health Literature (CINAHL). Le critère de jugement principal est la consommation intraveineuse de morphine cumulée à 6 h postopératoires, analysée selon le type de chirurgie (laparotomie, laparoscopie, césarienne), la technique anesthésique (anesthésie générale, anesthésie spinale avec/ou sans morphine intrathécale), le moment de l'injection (début ou fin de l'intervention), et la présence ou non d'une analgésie multimodale. Les critères de jugement secondaires sont, entre autres, les scores de douleur au repos et à l'effort à 6 h postopératoires (échelle analogique de 0 à 100), la présence ou non de nausées et vomissements postopératoires, la présence ou non de prurit, et le taux de complications de la technique. Résultats : Trente et une études randomisées contrôlées, incluant un total de 1611 adultes ont été incluses. Indépendamment du type de chirurgie, le bloc TAP échoguidé réduit la consommation de morphine à 6 h postopératoires (différence moyenne : 6 mg ; 95%IC : -7, -4 mg ; I =94% ; p<0.00001), sauf si les patients sont au bénéfice d'une anesthésie spinale avec morphine intrathécale. Le degré de réduction de consommation de morphine n'est pas influencé par le moment de l'injection (I2=0% ; p=0.72) ou la présence d'une analgésie multimodale (I2=73% ; p=0.05). Les scores de douleurs au repos et à l'effort à 6h postopératoire sont également réduits (différence moyenne au repos : -10 ; 95%IC : -15, -5 ; I =92% ; p=0.0002; différence moyenne en mouvement : -9 ; 95%IC : -14, -5 ; I2=58% ; p<0. 00001). Aucune différence n'a été retrouvée au niveau des nausées et vomissements postopératoires et du prurit. Deux complications mineures ont été identifiées (1 hématome, 1 réaction anaphylactoïde sur 1028 patients). Conclusions : Le bloc TAP échoguidé procure une analgésie postopératoire mineure et ne présente aucun bénéfice chez les patients ayant reçu de la morphine intrathécale. L'effet analgésique mineure est indépendant du moment de l'injection ou de la présence ou non d'une analgésie multimodale.
Resumo:
BACKGROUND: Adaptations to Internal (IR) and external (ER) rotator shoulder muscles improving overhead throwing kinematics could lead to muscular strength imbalances and be considered an intrinsic risk factor for shoulder injury, as well as modified shoulder range of motion (RoM). OBJECTIVE: To establish profiles of internal and external rotation RoM and isokinetic IR and ER strength in adolescent- and national-level javelin throwers. METHODS: Fourteen healthy subjects were included in this preliminary cross-sectional study, 7 javelin throwers (JTG) and 7 nonathletes (CG). Passive internal and external rotation RoM were measured at 90 degrees of shoulder abduction. Isokinetic strength of dominant and non-dominant IR and ER was evaluated during concentric (60, 120 and 240 degrees/s) and eccentric (60 degrees/s) contractions by Con-Trex (R) dynamometer with the subject in a seated position with 45 degrees of shoulder abduction in the scapular plane. RESULTS: We reported significantly lower internal rotation and significantly higher external rotation RoM in JTG than in CG. Concentric and eccentric IR and ER strength were significantly higher for the dominant shoulder side in JTG (P < 0.05), without significant differences in ER/IR ratios. CONCLUSIONS: The main finding of this preliminary study confirmed static and dynamic shoulder stabilizer adaptations due to javelin throw practice in a population of adolescent- and national-level javelin throwers.
Resumo:
Abstract : Textural division of a mineral in pyramids, with their apices located at the centre of the mineral and their bases corresponding to the mineral faces is called textural sector zoning. Textural sector zoning is observed in many metamorphic minerals like andalousite and garnet. Garnets found in the graphite rich black shales of the Mesozoic cover of the Gotthard Massif display textural sector zoning. The morphology of this sector zoning is not the same in different types of black shales observed in the Nufenen pass area. Garnets in foliated black shales display a well developed sector zoning while garnets found in cm-scale layered black shales display well developed sectors in the direction of the schistosity plane. This sector zoning is always associated with up to 30μm sized birefringent lamellae emanating radial from the sector boundaries. They alternate with isotrope lamellae. The garnet forming reaction was determined using singular value decomposition approach and results compared to thermodynamic calculations. It is of the form chl + mu + cc + cld = bt + fds + ank + gt + czo and is similar in both layered and foliated black shales. The calculated X(O) is close to 0.36 and does not significantly vary during the metamorphic history of the rock. This corresponds to X CO2, X CH4, and X H2O BSE imaging of garnets on oriented-cuts revealed that the orientation of the lamellae found within the sectors is controlled by crystallography. BSE imaging and electron microprobe analysis revealed that these lamellae are calcium rich compared to the isotropic lamellae. The addition of Ca to an almandine rich garnet causes a small distortion of the X site and potentially, ordering. Ordered and disordered garnet might have very similar free energies for this composition. Hence, two garnets with different composition can be precipitated with minor overstepping of the reaction. It is enough that continued nucleation of a new garnet layer slightly prefers the same structure to assure a fiber-like growth of both garnet compositions side by side. This hypothesis is in agreement with the thermodynamic properties of the garnet solid solution described in the literature and could explain the textures observed in garnets with these compositions. To understand the differences in sector zoning morphology, and crystal growth kinetics, crystal size distribution were determined in several samples using 2D spatial analysis of slab surfaces. The same nucleation rate law was chosen for all cases. Different growth rate law for non-layered black shales and layered black shales were used. Garnet in layered black shales grew according to a growth rate law of the form R=kt ½. The transport of nutrient is the limiting factor. Transport will occur preferentially on the schistosity planes. The shapes of the garnets in such rocks are therefore ovoid with the longest axis parallel to the schistosity planes. Sector zoning is less developed with sectors present only parallel to the schistosity planes. Garnet in non-layered blackshales grew according to a growth rate law of the form R=kt. The limiting factor is the attachment at the surface of the garnet. Garnets in these rocks will display a well developed sector zoning in all directions. The growth rate law is thus influenced by the texture of the rock. It favours or hinders the transport of nutrient to the mineral surface. Résumé : La zonation sectorielle texturale consiste en la division d'un cristal en pyramides dont les sommets sont localisés au centre du minéral. La base de ces pyramides correspond aux faces du minéral. Ce type de zonation est fréquemment observé dans les minéraux métamorphiques tels que l'andalousite ou le grenat. Les grenats présents dans les marnes riches en graphites de la couverture Mésozoïque du Massif du Gotthard présent une zonation sectorielle texturale. La morphologie de cette zonation n'est pas la même dans les marnes litées et dans les marnes foliées. Les grenats des marnes foliées montrent des secteurs bien développés dans 3 directions. Les grenats des marnes litées montrent des secteurs développés uniquement dans la direction des plans de schistosité. Cette zonation sectorielle est toujours associée à des lamelles biréfringentes de quelques microns de large qui partent de la limite des secteurs et qui sont perpendiculaires aux faces du grenat. Ces lamelles alternent avec des lamelles isotropes. La réaction de formation du grenat a été déterminée par calcul matriciel et thermodynamique. La réaction est de la forme chl + mu + cc + cld= bt + fds + ank + gt + czo. Elle est similaire dans les roches litées et dans les roches foliées. L'évaluation des conditions fluides montrent que le X(O) est proche de 0.36 et ne change pas de façon significative durant l'histoire métamorphique de la roche. Des images BSE sur des coupes orientées ont révélé que l'orientation de lamelles biréfringentes est contrôlée parla crystallographie. La comparaison des analyses à la microsonde électronique et des images BSE révèle également que les lamelles biréfringentes sont plus riches en calcium que les lamelles isotropes. L'addition de calcium va déformer légèrement le site X et ainsi créer un ordre sur ce site. L'énergie interne d'un grenat ordré et d'un grenat désordonné sont suffisamment proches pour qu'un léger dépassement de l'énergie de la réaction de formation permette la coexistence des 2 types de grenat dans le même minéral. La formation de lamelles est expliquée par le fait qu'un grenat préférera la même structure. Ces observations sont en accord avec la thermodynamique des solutions solides du grenat et permet d'expliquer les structures similaires observées dans des grenats provenant de lithologies différentes. Une étude de la distribution des tailles des grenats et une modélisation de la croissance a permis de mettre en évidence 2 mécanismes de croissance différents suivant la texture de la roche. Dans les 2 cas, la loi de nucléation est la même. Dans les roches litées, la loi de croissance est de forme R=kt½. Le transport des nutriments est le facteur limitant. Ce transport a lieu préférentiellement dans la direction des niveaux de schistosité. Les grenats ont une forme légèrement allongée car la croissance des secteurs est facilitée sur les niveaux de schistosité. La croissance des grenats dans les roches foliées suit une loi de croissance de la forme R=kt. Les seuls facteurs limitant la croissance sont les processus d'attachement à la surface du grenat. La loi de croissance de ces grenats est donc contrainte par la texture de la roche. Cela se marque par des différences dans la morphologie de la zonation sectorielle.
Resumo:
Phototropism is an adaptive response allowing plants to optimize photosynthetic light capture. This is achieved by asymmetric growth between the shaded and lit sides of the stimulated organ. In grass seedlings, the site of phototropin-mediated light perception is distinct from the site of bending; however, in dicotyledonous plants (e.g., Arabidopsis), spatial aspects of perception remain debatable. We use morphological studies and genetics to show that phototropism can occur in the absence of the root, lower hypocotyl, hypocotyl apex, and cotyledons. Tissue-specific expression of the phototropin1 (phot1) photoreceptor demonstrates that light sensing occurs in the upper hypocotyl and that expression of phot1 in the hypocotyl elongation zone is sufficient to enable a normal phototropic response. Moreover, we show that efficient phototropism occurs when phot1 is expressed from endodermal, cortical, or epidermal cells and that its local activation rapidly leads to a global response throughout the seedling. We propose that spatial aspects in the steps leading from light perception to growth reorientation during phototropism differ between grasses and dicots. These results are important to properly interpret genetic experiments and establish a model connecting light perception to the growth response, including cellular and morphological aspects.