37 resultados para Galaxy: disk


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pollination syndromes involve convergent evolution towards phenotypes composed of specific scents, colours or floral morphologies that attract or restrict pollinator access to reward. How these traits might influence the distributions of plant species in interaction with pollinators has rarely been investigated. We sampled 870 vegetation plots in the western Swiss Alps and classified the plant species into seven blossom types according to their floral morphology (wind, disk, funnel, tube, bilabiate, head or brush). We investigated the environmental features of plots with functional diversity (FD) lower than expected by chance alone to detect potential pollination filtering and related the proportions of the seven blossom types to a combination of environmental descriptors. From these results, we inferred the potential effect of the pollinator on the spatial distribution of plant species. The vegetation plots with significantly lower FD of blossom types than expected by chance were found at higher altitudes, and the proportions of blossom types were strongly patterned along the same gradient. These results support a biotic filtering effect on plant species assemblages through pollination: disk blossoms became dominant at higher altitudes, resulting in a lower FD. In harsh conditions at high altitudes, pollinators usually decrease in activity, and the openness of the disk blossom grants access to any available pollinator. Inversely, bilabiate blossoms, which are mostly pollinated by bees, were more abundant at lower elevations, which are characterised by greater abundance and diversity of bees. Generalisation through openness of the blossom could be advantageous at high elevations, while specialisation could be a successful alternative strategy at lower elevations. The approach used in this study is purely correlative, and further investigations should be conducted to infer the nature of the causal relationship between plant and pollinator distributions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Endoresection of choroidal melanoma may offer the best hope of conserving vision in some patients but is controversial because of concerns regarding iatrogenic tumour dissemination. METHODS: Retrospective, non-randomised study of consecutive patients who underwent endoresection for choroidal melanoma at the Liverpool Ocular Oncology Centre between 1996 and 2010. RESULTS: The study included 71 patients with a mean age of 58.7 years. The tumour extended within 2 disc diameters of the optic disc in 46 (65%) eyes, involving the disc in 24 (34%) eyes. The mean largest basal tumour diameter and tumour thickness were 9.5 mm and 4.4 mm, respectively. The median follow-up was 4.1 years. The visual acuity at the latest follow-up was better than 6/30 in 31% eyes. The main causes of visual loss were foveal excision, rhegmatogenous retinal detachment (RD) and proliferative vitreo-retinopathy (PVR). Local recurrence developed in two patients (3%), who were treated by enucleation and proton beam radiotherapy, respectively. RD occurred in 16 cases (22%). Three (4%) eyes were enucleated, two because of PVR and one because of local tumour recurrence. Five patients died of metastatic disease. CONCLUSIONS: Endoresection achieved high rates of local tumour control. This operation would seem to be a useful alternative to radiotherapy as a means of conserving vision in eyes with juxtapapillary melanoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The infection of an intervertebral disk is a serious condition. The diagnosis often is elusive and difficult to make. It is imperative to have appropriate microbiologic specimens before the initiation of treatment. We report the case of a 51-year-old woman with lumbar spondylodiscitis caused by infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging (MRI) scan confirmed the diagnosis, but computed tomography (CT)-guided fine-needle biopsy did not yield adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. We believe that this minimally invasive procedure should be performed when CT-guided fine-needle biopsy fails to yield a microbiologic diagnosis in spondylodiscitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article summarizes the available evidence on the management of patients with subacute or chronic low back pain. The largest part is devoted to nonspecific low back pain but the models of spinal stenosis and disk herniation/sciatica are also specifically addressed. The authors point out the limited evidence available and the importance of a tailored approach for the individual patient. As the effect sizes of most therapies are rather small (close to that of a placebo), patients' preferences and other variables important for individualized management are highlighted. The task for the practitioner is difficult and awareness of this is important. Some speculation regarding potential future ways of improving patient care are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY DESIGN: Double-blind, placebo-controlled randomized clinical trial. OBJECTIVE: To assess the efficacy of 1 preoperative 1.5 g dose of cefuroxime in preventing surgical site infection after surgery for herniated disc. SUMMARY OF BACKGROUND DATA: Antibiotic prophylaxis was only tested in nonconclusive trials in this setting. METHODS: The study was conducted in 2 university hospitals in Switzerland. Patients were assessed for occurrence of surgical site infection (defined by the criteria of the Centers for Diseases Control and Prevention), other infections, or adverse events up to 6 months after surgery. Outcome measures were compared in a univariate, per-protocol analysis. RESULTS: Baseline characteristics were similar in patients allocated to cefuroxime (n = 613) or placebo (n = 624). Eight (1.3%) patients in the cefuroxime group and 18 patients (2.8%) in the placebo group developed a surgical site infection (P = 0.073). A diagnosis of spondylodiscitis or epidural abscess was made in 9 patients in the placebo group, but none in the cefuroxime group (P < 0.01), which corresponded to a number necessary to treat of 69 patients to prevent one of these infections. There were no significant adverse events attributed to either cefuroxime or placebo. CONCLUSION: A single, preoperative dose of cefuroxime significantly reduces the risk of organ-space infection, most notably spondylodiscitis, after surgery for herniated disc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MoS(x) lubricating thin films were deposited by nonreactive, reactive, and low energy ion-assisted radio-frequency (rf) magnetron sputtering from a MoS2 target. Depending on the total and reactive gas pressures, the film composition ranges between MoS0.7 and MoS2.8. A low working pressure was found to have effects similar to those of low-energy ion irradiation. Films deposited at high pressure have (002) planes preferentially perpendicular to the substrate, whereas films deposited at low pressure or under low-energy ion irradiation have (002) mainly parallel to it. Parallel films are sulfur deficient (MoS1.2-1.4). Their growth is explained in terms of an increased reactivity of the basal surfaces, itself a consequence of the creation of surface defects due to ion irradiation. The films exhibit a lubricating character for all compositions above MoS1.2. The longest lifetime in ball-on-disk wear test was found for MoS1.5.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fluconazole 25 microg disk diffusion test was used to test 2230 consecutively isolated Candida strains from 42 different hospital laboratories in 23 countries. Ninety seven percent of 1634 Candida albicans isolates and 83.4% of 596 non-Candida albicans isolates were susceptible to fluconazole, applying the proposed breakpoints (> or = 26 mm for susceptible strains and 18-25 mm for dose-dependent susceptible strains). This is the first hospital laboratory study to evaluate a large number and wide range of sequential Candida isolates from patients with all types of hospital infections. The fluconazole disk diffusion test appears to be a low-cost, reproducible, and accurate means of assessing the in vitro susceptibility of Candida isolates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of the quantitative antibiogram as an epidemiological tool for the prospective typing of methicillin-resistant Staphylococcus aureus (MRSA), and comparison with ribotyping. METHODS: The method is based on the multivariate analysis of inhibition zone diameters of antibiotics in disk diffusion tests. Five antibiotics were used (erythromycin, clindamycin, cotrimoxazole, gentamicin, and ciprofloxacin). Ribotyping was performed using seven restriction enzymes (EcoRV, HindIII, KpnI, PstI, EcoRI, SfuI, and BamHI). SETTING: 1,000-bed tertiary university medical center. RESULTS: During a 1-year period, 31 patients were found to be infected or colonized with MRSA. Cluster analysis of antibiogram data showed nine distinct antibiotypes. Four antibiotypes were isolated from multiple patients (2, 4, 7, and 13, respectively). Five additional antibiotypes were isolated from the remaining five patients. When analyzed with respect to the epidemiological data, the method was found to be equivalent to ribotyping. Among 206 staff members who were screened, six were carriers of MRSA. Both typing methods identified concordant of MRSA types in staff members and in the patients under their care. CONCLUSIONS: The quantitative antibiogram was found to be equivalent to ribotyping as an epidemiological tool for typing of MRSA in our setting. Thus, this simple, rapid, and readily available method appears to be suitable for the prospective surveillance and control of MRSA for hospitals that do not have molecular typing facilities and in which MRSA isolates are not uniformly resistant or susceptible to the antibiotics tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En Suisse, la variabilité géographique de la consommation de soins chirurgicaux est un domaine encore inexploré. Ce rapport examine de manière descriptive trois interventions chirurgicales réalisées en Suisse entre 2003 et 2005 : la prothèse partielle ou totale de hanche, la prothèse de genou et la cure de hernie discale. Il se concentre sur les caractéristiques démographiques des patients opérés, leur diagnostic et les différences des taux d'intervention selon les cantons. Les résultats sont présentés sous forme de taux bruts, de taux standardisés et de cartes géographiques de distribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbapenemases should be accurately and rapidly detected, given their possible epidemiological spread and their impact on treatment options. Here, we developed a simple, easy and rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based assay to detect carbapenemases and compared this innovative test with four other diagnostic approaches on 47 clinical isolates. Tandem mass spectrometry (MS-MS) was also used to determine accurately the amount of antibiotic present in the supernatant after 1 h of incubation and both MALDI-TOF and MS-MS approaches exhibited a 100% sensitivity and a 100% specificity. By comparison, molecular genetic techniques (Check-MDR Carba PCR and Check-MDR CT103 microarray) showed a 90.5% sensitivity and a 100% specificity, as two strains of Aeromonas were not detected because their chromosomal carbapenemase is not targeted by probes used in both kits. Altogether, this innovative MALDI-TOF-based approach that uses a stable 10-μg disk of ertapenem was highly efficient in detecting carbapenemase, with a sensitivity higher than that of PCR and microarray.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two cases of a benign form of optic disc edema after successful trabeculectomy are reported. In both patients, optic disc edema was noted 2 to 4 weeks after trabeculectomy. The edema occurred without loss of visual acuity or field. The absolute intraocular pressure and intracranial pressure were normal--that is, the edema was not a syndrome of hypotony or pseudotumor cerebri. However, both patients had intracranial pressure in the high-normal range. The decrease in intraocular pressure into the low normal range after trabeculectomy may have altered the intracranial pressure:intraocular pressure ratio at the lamina cribrosa enough to produce optic disc edema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

10.00% 10.00%

Publicador: