80 resultados para Fotografia digital


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) is a technique that allows obtaining, from a single recorded hologram, quantitative phase image of living cell with interferometric accuracy. Specifically the optical phase shift induced by the specimen on the transmitted wave front can be regarded as a powerful endogenous contrast agent, depending on both the thickness and the refractive index of the sample. Thanks to a decoupling procedure cell thickness and intracellular refractive index can be measured separately. Consequently, Mean corpuscular volume (MCV) and mean corpuscular hemoglobin concentration (MCHC), two highly relevant clinical parameters, have been measured non-invasively at a single cell level. The DHM nanometric axial and microsecond temporal sensitivities have permitted to measure the red blood cell membrane fluctuations (CMF) on the whole cell surface. ©2009 COPYRIGHT SPIE--The International Society for Optical Engineering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractDigitalization gives to the Internet the power by allowing several virtual representations of reality, including that of identity. We leave an increasingly digital footprint in cyberspace and this situation puts our identity at high risks. Privacy is a right and fundamental social value that could play a key role as a medium to secure digital identities. Identity functionality is increasingly delivered as sets of services, rather than monolithic applications. So, an identity layer in which identity and privacy management services are loosely coupled, publicly hosted and available to on-demand calls could be more realistic and an acceptable situation. Identity and privacy should be interoperable and distributed through the adoption of service-orientation and implementation based on open standards (technical interoperability). Ihe objective of this project is to provide a way to implement interoperable user-centric digital identity-related privacy to respond to the need of distributed nature of federated identity systems. It is recognized that technical initiatives, emerging standards and protocols are not enough to guarantee resolution for the concerns surrounding a multi-facets and complex issue of identity and privacy. For this reason they should be apprehended within a global perspective through an integrated and a multidisciplinary approach. The approach dictates that privacy law, policies, regulations and technologies are to be crafted together from the start, rather than attaching it to digital identity after the fact. Thus, we draw Digital Identity-Related Privacy (DigldeRP) requirements from global, domestic and business-specific privacy policies. The requirements take shape of business interoperability. We suggest a layered implementation framework (DigldeRP framework) in accordance to model-driven architecture (MDA) approach that would help organizations' security team to turn business interoperability into technical interoperability in the form of a set of services that could accommodate Service-Oriented Architecture (SOA): Privacy-as-a-set-of- services (PaaSS) system. DigldeRP Framework will serve as a basis for vital understanding between business management and technical managers on digital identity related privacy initiatives. The layered DigldeRP framework presents five practical layers as an ordered sequence as a basis of DigldeRP project roadmap, however, in practice, there is an iterative process to assure that each layer supports effectively and enforces requirements of the adjacent ones. Each layer is composed by a set of blocks, which determine a roadmap that security team could follow to successfully implement PaaSS. Several blocks' descriptions are based on OMG SoaML modeling language and BPMN processes description. We identified, designed and implemented seven services that form PaaSS and described their consumption. PaaSS Java QEE project), WSDL, and XSD codes are given and explained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital Holographic Microscopy (DHM), is a new imaging technique allowing to provide quantitative phase images with a high accuracy and stability making possible to explore a large variety of relevant processes, occurring on the p.s to day time scale, in the fields including material research as well as cell biology. As a non invasive and real time imaging technique, DHM is particularly well suited for high throughput screening

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The field of classical studies has undergone a radical transformation with the arrival of the digital age, particularly with regard to the editing of ancient texts. As Umberto Eco (2003) pointed out, the digital age may mean the end of the history of variants and of the notion of the "original text." Among the texts of antiquity, the editing of Homer and of the New Testament are more especially susceptible to the effects of digital technology because of their numerous manuscripts. Whereas the "Homer Multitext" project recognizes that the notion of a synthetic critical edition is now seriously brought into question, the prototype of the online Greek New Testament continues to be based on the aim of obtaining a unique text, in the style of a printed critical edition. As it moves from a printed culture to the digital age, the editing of the Greek NT is also confronted by the emergence of non-Western scholarship. For example, the presence is to be noted of Arabic Muslim websites that examine Greek New Testament manuscripts but without directly interacting with Western scholarship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present first results on a method enabling mechanical scanning-free tomography with submicrometer axial resolution by multiple-wavelength digital holographic microscopy. By sequentially acquiring reflection holograms and summing 20 wavefronts equally spaced in spatial frequency in the 485-670 nm range, we are able to achieve a slice-by-slice tomographic reconstruction with a 0.6-1 mum axial resolution in a biological medium. The method is applied to erythrocytes investigation to retrieve the cellular membrane profile in three dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.