70 resultados para Film, Radio
Resumo:
The oncologic outcome and the total dose are highly correlated with the treatment by ionizing radiation. The dose increase (total or per fraction) may provoke late-side effects that are potentially irreversible. The radiation-induced CD8 lymphocyte apoptotic value and the molecular modifications within the lymphocyte are capable of predicting the level of risk of developing late-side effects after curative intent radiotherapy. In this review, we present the different blood assays in this setting and discuss the current possibilities of researches, namely those involving the proteomic process.
Resumo:
In endoscopic sinus surgery, knowledge of the course of the internal ethmoida and orbital arteries is crucial.The maxillary and the internal carotid arteries of cadavers were injected with radio-opaque , red colorede silicone. The ethmoidal regions were perpared and plastinated using the standard S10 technique. On some specimens, the ophtalmic and ethmoidal arteries were dissected prior to plastination. The plastinated specimens of the ethmoidal blocks were successfullyintroduced into clinical teaching of sinus anatomy and surgery as an aid to study vaascularization an dits relationship to surgical procedures. Among the advantages of this method are the long-lasting preservation of dissected tissue, visualization of arteries during endoscopic and radiological examinations, and invaluable teachjing and training resources for endoscopic sinus surgery.
Resumo:
Geoelectrical techniques are widely used to monitor groundwater processes, while surprisingly few studies have considered audio (AMT) and radio (RMT) magnetotellurics for such purposes. In this numerical investigation, we analyze to what extent inversion results based on AMT and RMT monitoring data can be improved by (1) time-lapse difference inversion; (2) incorporation of statistical information about the expected model update (i.e., the model regularization is based on a geostatistical model); (3) using alternative model norms to quantify temporal changes (i.e., approximations of l(1) and Cauchy norms using iteratively reweighted least-squares), (4) constraining model updates to predefined ranges (i.e., using Lagrange Multipliers to only allow either increases or decreases of electrical resistivity with respect to background conditions). To do so, we consider a simple illustrative model and a more realistic test case related to seawater intrusion. The results are encouraging and show significant improvements when using time-lapse difference inversion with non l(2) model norms. Artifacts that may arise when imposing compactness of regions with temporal changes can be suppressed through inequality constraints to yield models without oscillations outside the true region of temporal changes. Based on these results, we recommend approximate l(1)-norm solutions as they can resolve both sharp and smooth interfaces within the same model. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
Two 131-Iodine radiolabelled monoclonal antibodies were used to perform tomoscintigraphy in 42 patients: 11 patients bearing medullary thyroid cancers and 19 patients bearing gastrointestinal cancers received an antibody directed against carcino-embryonic antigen; 12 patients bearing gastro-intestinal cancers received an antibody directed against a non circulating antigen expressed by human colorectal cancers cell lines. Tomoscintigraphy is particularly useful for analysing the complex biodistribution of radiolabelled antibodies and the low contrast images encountered in immunoscintigraphy; the problems related to the true positive rate and to the clinical specificity of the method are discussed.
Resumo:
Advanced stage follicular lymphoma is incurable by conventional treatment. Important progress has been observed with the development of new therapies based on monoclonal antibodies and on the use of radioimmunotherapy (RIT) in the treatment of non-Hodgkin lymphomas (NHL). Rituximab in combination with chemotherapy in the upfront setting significantly improved treatment outcome as compared with chemotherapy alone. Different studies also indicate that RIT has an important role in the management of NHL and could be beneficial in combination with chemotherapy. These two new treatment options have clearly distinctive mechanisms of action, rituximab being an exclusively biological treatment and RIT adding targeted systemic radiation therapy. Both RIT and the unlabeled antibody treatments might be further improved by different strategies including repetition of RIT or combination of different antibodies. We present here our experience with RIT using 131I-tositumomab (Bexxar) and discuss different topics regarding RIT, like the use of different antibodies, the best choice of the radioisotope or the place of radio-imaging. From the therapeutic point of view, we argue that the debate should not be as to which one among antibody immunotherapy or RIT should be best added to chemotherapy, but that all three treatments might be optimally combined with the aim to get the highest chance of cure for advanced stage follicular lymphoma.
Resumo:
Normal rats were injected intravenously with 131I- and 125I-labeled intact murine and chimeric mouse-human monoclonal antibodies directed against carcinoembryonic antigen or with the corresponding F(ab')2 fragments. At different times after injection, individual animals were killed and radioactivity of blood and major organs, including bones and bone marrow, was determined. Ratios comparing radioactivity concentration in different tissues with that of bone marrow were calculated and found to remain stable during several effective half-lives of the antibodies. Mean bone marrow radioactivity was 35% (range, 29%-40%) of that of blood and 126% (range, 108%-147%) of that of liver after injection of intact Mabs or F(ab')2 fragments. In nude rats bearing human colon carcinoma xenografts producing carcinoembryonic antigen, relative bone marrow radioactivity was slightly lower than that in normal rats.
Resumo:
We investigated respiratory responses during film clip viewing and their relation to the affective dimensions of valence and arousal. Seventy-six subjects participated in a study using a between groups design. To begin with, all participants viewed an emotionally neutral film clip. Then, they were presented with one out of four emotional film clips: a positive high-arousal, a positive low-arousal, a negative high-arousal and a negative low-arousal clip. Respiration, skin conductance level, heart rate, corrugator activity and affective judgments were measured. Expiratory time was shorter and inspiratory duty cycle, mean expiratory flow and minute ventilation were larger during the high-arousal clips compared to the low-arousal clips. The pleasantness of the stimuli had no influence on any respiratory measure. These findings confirm the importance of arousal in respiratory responding but also evidence differences in comparison to previous studies using visual and auditory stimuli. [Authors]
Resumo:
MoS(x) lubricating thin films were deposited by nonreactive, reactive, and low energy ion-assisted radio-frequency (rf) magnetron sputtering from a MoS2 target. Depending on the total and reactive gas pressures, the film composition ranges between MoS0.7 and MoS2.8. A low working pressure was found to have effects similar to those of low-energy ion irradiation. Films deposited at high pressure have (002) planes preferentially perpendicular to the substrate, whereas films deposited at low pressure or under low-energy ion irradiation have (002) mainly parallel to it. Parallel films are sulfur deficient (MoS1.2-1.4). Their growth is explained in terms of an increased reactivity of the basal surfaces, itself a consequence of the creation of surface defects due to ion irradiation. The films exhibit a lubricating character for all compositions above MoS1.2. The longest lifetime in ball-on-disk wear test was found for MoS1.5.