25 resultados para Dry chamber


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the various health influencing parameters related to engineered nanoparticles as well as to soot emitted b diesel engines, there is an urgent need for appropriate sampling devices and methods for cell exposure studies that simulate the respiratory system and facilitate associated biological and toxicological tests. The objective of the present work was the further advancement of a Multiculture Exposure Chamber (MEC) into a dose-controlled system for efficient delivery of nanoparticles to cells. It was validated with various types of nanoparticles (diesel engine soot aggregates, engineered nanoparticles for various applications) and with state-of-the-art nanoparticle measurement instrumentation to assess the local deposition of nanoparticles on the cell cultures. The dose of nanoparticles to which cell cultures are being exposed was evaluated in the normal operation of the in vitro cell culture exposure chamber based on measurements of the size specific nanoparticle collection efficiency of a cell free device. The average efficiency in delivering nanoparticles in the MEC was approximately 82%. The nanoparticle deposition was demonstrated by Transmission Electron Microscopy (TEM). Analysis and design of the MEC employs Computational Fluid Dynamics (CFD) and true to geometry representations of nanoparticles with the aim to assess the uniformity of nanoparticle deposition among the culture wells. Final testing of the dose-controlled cell exposure system was performed by exposing A549 lung cell cultures to fluorescently labeled nanoparticles. Delivery of aerosolized nanoparticles was demonstrated by visualization of the nanoparticle fluorescence in the cell cultures following exposure. Also monitored was the potential of the aerosolized nanoparticles to generate reactive oxygen species (ROS) (e.g. free radicals and peroxides generation), thus expressing the oxidative stress of the cells which can cause extensive cellular damage or damage on DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In previous studies we showed that the wild-type histamine H(2) receptor stably expressed in Chinese hamster ovary cells is constitutively active. Because constitutive activity of the H(2) receptor is already found at low expression levels (300 fmol/mg protein) this receptor is a relatively unique member of the G-protein-coupled receptor (GPCR) family and a useful tool for studying GPCR activation. In this study the role of the highly conserved DRY motif in activation of the H(2) receptor was investigated. Mutation of the aspartate 115 residue in this motif resulted in H(2) receptors with high constitutive activity, increased agonist affinity, and increased signaling properties. In addition, the mutant receptors were shown to be highly structurally instable. Mutation of the arginine 116 residue in the DRY motif resulted also in a highly structurally instable receptor; expression of the receptor could only be detected after stabilization with either an agonist or inverse agonist. Moreover, the agonist affinity at the Arg-116 mutant receptors was increased, whereas the signal transduction properties of these receptors were decreased. We conclude that the Arg-116 mutant receptors can adopt an active conformation but have a decreased ability to couple to or activate the G(s)-protein. This study examines the pivotal role of the aspartate and arginine residues of the DRY motif in GPCR function. Disruption of receptor stabilizing constraints by mutation in the DRY motif leads to the formation of active GPCR conformations, but concomitantly to GPCR instability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Asthma is one of the most frequent chronic diseases affecting children and adolescents. Good compliance is indispensable for effective treatment since a suboptimal use of inhalation devices can result in decreased therapeutic efficacy and increased morbidity. The objective of this work was to evaluate the inhalation technique of paediatric patients visiting a specialized consultation clinic of a university hospital. Design: Observational prospective study during a 3-month period. Setting Specialized consultation clinic of a university hospital. Main outcome measures: This study involved 40 outpatient infants, children and adolescents visiting alone or with their parent(s). Patients' data (age, sex, weight, diagnostic, reason for consulting, previous consultations) and their medicines were compiled using an ad hoc form. Filmed sequences of the inhalation procedure used by each child were reviewed independently by members of an interdisciplinary team consisting in a physician, a pharmacist, a nurse and a physiotherapist. A score of 1 was assigned to each correct step in the procedure, and a score of 0 to an incorrect step. A perfect procedure implied 12 correct steps. Results: Thirty patients were treated with a metered-dose inhaler and an inhalation chamber (Babyhaler or AeroChamber Plus); ten other patients were treated with a dry powder inhaler (Diskus or Turbuhaler). The agreement between the members of the interdisciplinary team was considered satisfactory. Nine patients (22.5%) reached an average score lower than 7, 18 patients (45%) a score between 7 and 10 and 13 (32.5%) a score equal to or better than 10. No patient reached the maximum score of 12. Users of the metered-dose inhalers (average score = 9.2) showed a better technique than users of the dry powder inhalers (average score = 7.4). Disappointingly, the score was not improved during a second consultation or following regular consultations. Conclusions: Video recording is a simple method to evaluate the degree of mastery of an inhalation procedure in paediatric patients. The method allows a convenient and efficient identification of suboptimal procedure steps by the hospital staff, and opens the way to patient-specific teaching. In two-thirds of juvenile patients, their inhalation technique was suboptimal despite initial training. This study shows conclusively that the inhalation technique in paediatric patients must be monitored during each examination, and teaching measures taken to improve it when necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of the present study was the in vitro and in vivo evaluation of a novel aqueous formulation based on polymeric micelles for the topical delivery of cyclosporine A for dry eye treatment. METHODS: In vitro experiments were carried out on primary rabbit corneal cells, which were characterized by immunocytochemistry using fluorescein-labeled lectin I/isolectin B4 for the endothelial cells and mouse monoclonal antibody to cytokeratin 3+12 for the epithelial ones. Living cells were incubated for 1 hour or 24 hours with a fluorescently labeled micelle formulation and analyzed by fluorescence microscopy. In vivo evaluations were done by Schirmer test, osmolarity measurement, CyA kinetics in tears, and CyA ocular distribution after topical instillation. A 0.05% CyA micelle formulation was compared to a marketed emulsion (Restasis). RESULTS: The in vitro experiments showed the internalization of micelles in the living cells. The Schirmer test and osmolarity measurements demonstrated that micelles did not alter the ocular surface properties. The evaluation of the tear fluid gave similar CyA kinetics values: AUC = 2339 ± 1032 min*μg/mL and 2321 ± 881.63; Cmax = 478 ± 111 μg/mL and 451 ± 74; half-life = 36 ± 9 min and 28 ± 9 for the micelle formulation and Restasis, respectively. The ocular distribution investigation revealed that the novel formulation delivered 1540 ± 400 ng CyA/g tissue to the cornea. CONCLUSIONS: The micelle formulation delivered active CyA into the cornea without evident negative influence on the ocular surface properties. This formulation could be applied for immune-related ocular surface diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The natural dissipation rates of sidestream smoke (SS) particles dispersed in a chamber were studied from the standpoint of a static atmosphere and were expressed as half-lives of residence in the air. The half-lives for particles less than 0.3 micron, 0.3-0.5 micron and 0.5-1 micron were found to be 25.5, 12.8 and 4.9 h, respectively. Total particulate matter (TPM) decreases by half after 6.2 h. Other data on diluted SS in the indoor air were also reported.