374 resultados para Cardiac weight
Resumo:
Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.
Resumo:
BACKGROUND: The SCN5A gene encodes for the α-subunit of the cardiac sodium channel NaV1.5, which is responsible for the rapid upstroke of the cardiac action potential. Mutations in this gene may lead to multiple life-threatening disorders of cardiac rhythm or are linked to structural cardiac defects. Here, we characterized a large family with a mutation in SCN5A presenting with an atrioventricular conduction disease and absence of Brugada syndrome. METHOD AND RESULTS: In a large family with a high incidence of sudden cardiac deaths, a heterozygous SCN5A mutation (p.1493delK) with an autosomal dominant inheritance has been identified. Mutation carriers were devoid of any cardiac structural changes. Typical ECG findings were an increased P-wave duration, an AV-block I° and a prolonged QRS duration with an intraventricular conduction delay and no signs for Brugada syndrome. HEK293 cells transfected with 1493delK showed strongly (5-fold) reduced Na(+) currents with altered inactivation kinetics compared to wild-type channels. Immunocytochemical staining demonstrated strongly decreased expression of SCN5A 1493delK in the sarcolemma consistent with an intracellular trafficking defect and thereby a loss-of-function. In addition, SCN5A 1493delK channels that reached cell membrane showed gain-of-function aspects (slowing of the fast inactivation, reduction in the relative fraction of channels that fast inactivate, hastening of the recovery from inactivation). CONCLUSION: In a large family, congregation of a heterozygous SCN5A gene mutation (p.1493delK) predisposes for conduction slowing without evidence for Brugada syndrome due to a predominantly trafficking defect that reduces Na(+) current and depolarization force.
Resumo:
In response to stress, the heart undergoes a remodeling process associated with cardiac hypertrophy that eventually leads to heart failure. A-kinase anchoring proteins (AKAPs) have been shown to coordinate numerous prohypertrophic signaling pathways in cultured cardiomyocytes. However, it remains to be established whether AKAP-based signaling complexes control cardiac hypertrophy and remodeling in vivo. In the current study, we show that AKAP-Lbc assembles a signaling complex composed of the kinases PKN, MLTK, MKK3, and p38α that mediates the activation of p38 in cardiomyocytes in response to stress signals. To address the role of this complex in cardiac remodeling, we generated transgenic mice displaying cardiomyocyte-specific overexpression of a molecular inhibitor of the interaction between AKAP-Lbc and the p38-activating module. Our results indicate that disruption of the AKAP-Lbc/p38 signaling complex inhibits compensatory cardiomyocyte hypertrophy in response to aortic banding-induced pressure overload and promotes early cardiac dysfunction associated with increased myocardial apoptosis, stress gene activation, and ventricular dilation. Attenuation of hypertrophy results from a reduced protein synthesis capacity, as indicated by decreased phosphorylation of 4E-binding protein 1 and ribosomal protein S6. These results indicate that AKAP-Lbc enhances p38-mediated hypertrophic signaling in the heart in response to abrupt increases in the afterload.
Resumo:
Introduction: Clinical examination and electroencephalography study (EEG) have been recommended to predict functional recovery in comatose survivors of cardiac arrest (CA), however their prognostic value in patients treated with induced hypothermia (IH) has not been evaluated. Hypothesis: We aimed to validate the prognostic ability of clinical examination and EEG in predicting outcome of patients with coma after CA treated with IH and sought to derive a score with high predictive value for poor functional outcome in this setting. Methods: We prospectively studied 100 consecutive comatose survivors of CA treated with IH. Repeated neurological examination and EEG were performed early after passive rewarming and off sedation. Mortality was assessed at hospital discharge, and functional outcome at 3 to 6 months with Cerebral Performance Categories (CPC), and was dichotomized as good (CPC 1-2) vs. poor (CPC 3-5). Independent predictors of outcome were identified by multivariable logistic regression and used to assess the prognostic value of a Reproducible Electro-clinical Prognosticators of Outcome Score (REPOS). Results: Patients (20/100) with good outcome had all a reactive EEG background. Incomplete recovery of brainstem reflexes, myoclonus, time to return of spontaneous circulation (ROSC) > 25 min, and unreactive EEG background were all independent predictors of death and severe disability, and were added to construct the REPOS. Using a cut-off of 0 or 1 variables for good vs. 2 to 4 for poor outcome, the REPOS had a positive predictive value of 1.00 (95% CI: 0.92-1.00), a negative predictive value of 0.43 (95% CI: 0.29-0.58) and an accuracy of 0.81 for poor functional recovery at 3 to 6 months. Conclusions: In comatose survivors of CA treated with IH, a prognostic score, including clinical and EEG examination, was highly predictive of death and poor functional outcome at 3 to 6 months. Lack of EEG background reactivity strongly predicted poor neurological recovery after CA. Our findings show that clinical and electrophysiological studies are effective in predicting long-term outcome of comatose survivors after CA and IH, and suggest that EEG improves early prognostic assessment in the setting of therapeutic cooling.
Resumo:
Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.
Resumo:
We have reported that ingesting a meal immediately after exercise increased skeletal muscle accretion and less adipose tissue accumulation in rats employed in a 10 week resistance exercise program. We hypothesized that a possible increase in the resting metabolic rate (RMR) as a result of the larger skeletal muscle mass might be responsible for the less adipose deposition. Therefore, the effect of the timing of a protein supplement after resistance exercise on body composition and the RMR was investigated in 17 slightly overweight men. The subjects participated in a 12-week weight reduction program consisting of mild energy restriction (17% energy intake reduction) and a light resistance exercise using a pair of dumbbells (3-5 kg). The subjects were assigned to two groups. Group S ingested a protein supplement (10 g protein, 7 g carbohydrate, 3.3 g fat and one-third of recommended daily allowance (RDA) of vitamins and minerals) immediately after exercise. Group C did not ingest the supplement. Daily intake of both energy and protein was equal between the two groups and the protein intake met the RDA. After 12 weeks, the bodyweight, skinfold thickness, girth of waist and hip and percentage bodyfat significantly decreased in the both groups, however, no significant differences were observed between the groups. The fat-free mass significantly decreased in C, whereas its decrease in S was not significant. The RMR and post-meal total energy output significantly increased in S, while these variables did not change in C. In addition, the urinary nitrogen excretion tended to increase in C but not in S. These results suggest that the RMR increase observed in S might be associated with an increase in body protein synthesis.
Resumo:
A high heart rate (HR) predicts future cardiovascular events. We explored the predictive value of HR in patients with high-risk hypertension and examined whether blood pressure reduction modifies this association. The participants were 15,193 patients with hypertension enrolled in the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial and followed up for 5 years. The HR was assessed from electrocardiographic recordings obtained annually throughout the study period. The primary end point was the interval to cardiac events. After adjustment for confounders, the hazard ratio of the composite cardiac primary end point for a 10-beats/min of the baseline HR increment was 1.16 (95% confidence interval 1.12 to 1.20). Compared to the lowest HR quintile, the adjusted hazard ratio in the highest quintile was 1.73 (95% confidence interval 1.46 to 2.04). Compared to the pooled lower quintiles of baseline HR, the annual incidence of primary end point in the top baseline quintile was greater in each of the 5 study years (all p <0.05). The adjusted hazard ratio for the primary end point in the highest in-trial HR heart rate quintile versus the lowest quintile was 1.53 (95% confidence interval 1.26 to 1.85). The incidence of primary end points in the highest in-trial HR group compared to the pooled 4 lower quintiles was 53% greater in patients with well-controlled blood pressure (p <0.001) and 34% greater in those with uncontrolled blood pressure (p = 0.002). In conclusion, an increased HR is a long-term predictor of cardiovascular events in patients with high-risk hypertension. This effect was not modified by good blood pressure control. It is not yet known whether a therapeutic reduction of HR would improve cardiovascular prognosis.
Resumo:
BackgroundIn Switzerland, socio-demographic and behavioural factors are associated with obesity, but no study ever assessed their impact on weight gain using prospective data.MethodsData from 4,469 participants (53.0% women), aged 35 to 75 years at baseline and followed for 5.5 years. Weight gain was considered as a rate (kg/year) or as gaining ¿5 kg during the study period.ResultsRate of weight gain was lower among participants who were older (mean¿±¿standard deviation: 0.46¿±¿0.92, 0.33¿±¿0.88, 0.21¿±¿0.86 and 0.06¿±¿0.74 kg/year in participants aged [35-45[, [45-55[, [55¿65[and [65+ years, respectively, P<0.001); physically active (0.27¿±¿0.82 vs. 0.35¿±¿0.95 kg/year for sedentary, P¿<¿0.005) or living in a couple (0.29¿±¿0.84 vs. 0.35¿±¿0.96 kg/year for living single, P¿<¿0.05), and higher among current smokers (0.41¿±¿0.97, 0.26¿±¿0.84 and 0.29±0.85 kg/year for current, former and never smokers, respectively, p<0.001). These findings were further confirmed by multivariable analysis. Multivariable logistic regression showed that receiving social help, being a current smoker or obese increased the likelihood of gaining ¿5Kg: Odds ratio (OR) and 95% confidence interval (CI) 1.43 (1.16-1.77); 1.63 (1.35-1.95) and 1.95 (1.57-2.43), respectively, while living in couple or being physically active decreased the risk: 0.73 (0.62-0.86) and 0.72 (0.62-0.83), respectively. No association was found between weight gain and gender, being born in Switzerland or education.ConclusionsIn Switzerland, financial difficulties (indicated by receiving social help) and current smoking were associated with increases in body weight over a 5 years follow-up. Living in couple, being older or physically active were protective against weight gain.
Resumo:
Rationale: Clinical and electrophysiological prognostic markers of brain anoxia have been mostly evaluated in comatose survivors of out hospital cardiac arrest (OHCA) after standard resuscitation, but their predictive value in patients treated with mild induced hypothermia (IH) is unknown. The objective of this study was to identify a predictive score of independent clinical and electrophysiological variables in comatose OHCA survivors treated with IH, aiming at a maximal positive predictive value (PPV) and a high negative predictive value (NPV) for mortality. Methods: We prospectively studied consecutive adult comatose OHCA survivors from April 2006 to May 2009, treated with mild IH to 33-34_C for 24h at the intensive care unit of the Lausanne University Hospital, Switzerland. IH was applied using an external cooling method. As soon as subjects passively rewarmed (body temperature >35_C) they underwent EEG and SSEP recordings (off sedation), and were examined by experienced neurologists at least twice. Patients with status epilepticus were treated with AED for at least 24h. A multivariable logistic regression was performed to identify independent predictors of mortality at hospital discharge. These were used to formulate a predictive score. Results: 100 patients were studied; 61 died. Age, gender and OHCA etiology (cardiac vs. non-cardiac) did not differ among survivors and nonsurvivors. Cardiac arrest type (non-ventricular fibrillation vs. ventricular fibrillation), time to return of spontaneous circulation (ROSC) >25min, failure to recover all brainstem reflexes, extensor or no motor response to pain, myoclonus, presence of epileptiform discharges on EEG, EEG background unreactive to pain, and bilaterally absent N20 on SSEP, were all significantly associated with mortality. Absent N20 was the only variable showing no false positive results. Multivariable logistic regression identified four independent predictors (Table). These were used to construct the score, and its predictive values were calculated after a cut-off of 0-1 vs. 2-4 predictors. We found a PPV of 1.00 (95% CI: 0.93-1.00), a NPV of 0.81 (95% CI: 0.67-0.91) and an accuracy of 0.93 for mortality. Among 9 patients who were predicted to survive by the score but eventually died, only 1 had absent N20. Conclusions: Pending validation in a larger cohort, this simple score represents a promising tool to identify patients who will survive, and most subjects who will not, after OHCA and IH. Furthermore, while SSEP are 100% predictive of poor outcome but not available in most hospitals, this study identifies EEG background reactivity as an important predictor after OHCA. The score appears robust even without SSEP, suggesting that SSEP and other investigations (e.g., mismatch negativity, serum NSE) might be principally needed to enhance prognostication in the small subgroup of patients failing to improve despite a favorable score.
Resumo:
OBJECTIVES: Thirty-two consecutive isolated modified Blalock Taussig (BT) shunts performed in infancy since 2004 were reviewed and analysed to identify the risk factors for shunt intervention and mortality. METHODS: Sternotomy was the only approach used. Median age and weight were 10.5 (range 1-74) days and 2.9 (1.9-4.4) kg, respectively. Shunt palliation was performed for biventricular hearts (Tetralogy of Fallot/double outlet right ventricle/transposition of great arteries_ventricular septal defect_pulmonary stenosis/pulmonary atresia_ventricular septal defect/others) in 21, and univentricular hearts in 11, patients. Hypoplastic left heart syndrome patients were excluded. Two procedures required cardiopulmonary bypass. Median shunt size was 3.5 (3-4) mm and median shunt size/kg body weight was 1.2 (0.9-1.7) mm/kg. Reduction in shunt size was necessary in 5 of 32 (16%) patients. RESULTS: Three of 32 (9%) patients died after 3 (1-15) days due to cardiorespiratory decompensation. Lower body weight (P = 0.04) and bigger shunt size/kg of body weight (P = 0.004) were significant risk factors for mortality. Acute shunt thrombosis was observed in 3 of 32 (9%), none leading to death. Need for cardiac decongestive therapy was associated with univentricular hearts (P < 0.001), bigger shunt size (P = 0.054) and longer hospital stay (P = 0.005). Twenty-eight patients have undergone a successful shunt takedown at a median age of 5.5 (0.5-11.9) months, without late mortality. CONCLUSIONS: Palliation with a modified BT shunt continues to be indicated despite increased thrust on primary corrective surgery. Though seemingly simple, it is associated with significant morbidity and mortality. Effective over-shunting and acute shunt thrombosis are the lingering problems of shunt therapy.
Resumo:
BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.
Resumo:
Introduction: Coarctation of the aorta is a common congenital heart malformation. Mode of diagnosis changed from clinically to almost exclusively by echocardiogram and MRI. We claim to find a new echocardiographic index, based on simple and reliable morphologic measurements, to facilitate the diagnosis of aortic coarctation in the newborn.We reproduce the same procedure for older child to validate this new index. Material and Methods: We reviewed echocardiographic studies of 47 neonates with diagnosis of coarctation who underwent cardiac surgery between January 1997 and February 2003 and compared them with a matched control group. We measured 12 different sites of the aorta, aortic arch and the great vessels on the echocardiographic bands. In a second time we reviewed 23 infants for the same measurements and compare them with a matched control group. Results: 47 neonates with coarctation were analysed, age 11.8 _ 10 days,weight 3.0 _ 0.6 kg, body surface 0.20 _ 0.02m2. The control group was of 16 newborns aged 15.8 _ 10 days,weight 3.2 _ 0.9 kg and body surface 0.20 _ 0.04m2. A significant difference was noted in many morphologic measurement between the both groups, the most significant being the distance between the left carotid artery and the left subclavian artery (coarctation vs control: 7.3 _ 3mm vs 2.4 _ 0.8mm, p _ 0.0001). We then defined a new index, the carotid-subclavian arteries index (CSI) as the diameter of the distal tranverse aortic arch divided to the distance left carotid artery to left subclavian artery being also significaly different (coarctation vs control: 0.76 _ 0.86 vs 2.95 _ 1.24, p _ 0.0001). With the cutoff value of this index of 1.5 the sensitivity for aortic coarctation was 98% and the specificity of 92%. In an older group of infant with coarctation (16 patients) we apply the same principle and find for a cut-off value of 1.5 a sensitivity of 95% and a specificity of 100%. Conclusions: The CSI allows to evaluate newborns and infants for aortic coarctation with simple morphologic measurement that are not depending of the left ventricular function, presence of a patent ductus arteriosus or not. Further aggressive evaluation of these patient with a CSI _ 1.5 is indicated.